Key Pages of Document

Please Read This Notice

Successful application of this module requires a reasonable working knowledge of the Schneider Electric Quantum / Unity hardware, the PTQ-LNG Module and the application in which the combination is to be used. For this reason, it is important that those responsible for implementation satisfy themselves that the combination will meet the needs of the application without exposing personnel or equipment to unsafe or inappropriate workin ...

PTQ-LNG ♦ Quantum / Unity Platform

Landis & Gyr Telegyr Interface Module ProSoft Technology, Inc. Page 3 of 103 May 29, 2007 Contents PLEASE READ THIS NOTICE...........................................................................................................2 Important Notice:...........................................................................................................................2 Your Feedback Please .................... ...

PTQ-LNG ♦ Quantum / Unity Platform

Contents Landis & Gyr Telegyr Interface Module Page 4 of 103 ProSoft Technology, Inc. May 29, 2007 7 DIAGNOSTICS AND TROUBLESHOOTING........................................................................... 65 7.1 Reading Status Data From the Module..................................................................... 65 7.1.1 The Configuration/Debug Menu ................................................................. ...

PTQ-LNG ♦ Quantum / Unity Platform

Landis & Gyr Telegyr Interface Module ProSoft Technology, Inc. Page 5 of 103 May 29, 2007 1 Start Here In This Chapter ¾ Hardware and Software Requirements .................................... 5 This guide is intended to guide you through the ProTalk module setup process, from removing the module from the box to exchanging data with the processor. In doing this, you will learn how to: ƒ Set up the processor ...

PTQ-LNG ♦ Quantum / Unity Platform

Start Here Landis & Gyr Telegyr Interface Module Page 6 of 103 ProSoft Technology, Inc. May 29, 2007 1454-9F DB-9 Female to 5 Pos Screw Terminal Adapter (Serial protocol modules only) ProSoft Solutions CD Note: The DB-9 Female to 5 Pos Screw Terminal Adapter is not required on Ethernet modules and is therefore not included in the carton with these types of modules. Quantum / Unity Hardware This guide assumes that you ar ...

Configuring the Processor with Concept

PTQ-LNG ♦ Quantum / Unity Platform Landis & Gyr Telegyr Interface Module ProSoft Technology, Inc. Page 7 of 103 May 29, 2007 2 Configuring the Processor with Concept In This Chapter ¾ Information for Concept Version 2.6 Users .............................. 7 ¾ Create a New Project............................................................... 9 ¾ Add the PTQ Module to the Project.................................. ...

PTQ-LNG ♦ Quantum / Unity Platform

Configuring the Processor with Concept Landis & Gyr Telegyr Interface Module Page 8 of 103 ProSoft Technology, Inc. May 29, 2007 This action opens the Concept Module Installation dialog box. 2 Choose File → Open Installation File. This action opens the Open Installation File dialog box: 3 If you are using a Quantum processor, you will need the MDC files. In the File/Open dialog box, navigate to the MDC Files directory ...

Configuring the Processor with Concept

PTQ-LNG ♦ Quantum / Unity Platform Landis & Gyr Telegyr Interface Module ProSoft Technology, Inc. Page 9 of 103 May 29, 2007 Select the files that go with the Concept version you are using, and then click OK. This action opens the Add New Modules dialog box. 5 Click the Add All button. A series of message boxes may appear during this process. Click Yes or OK for each message that appears. 6 When the process is compl ...

PTQ-LNG ♦ Quantum / Unity Platform

Configuring the Processor with Concept Landis & Gyr Telegyr Interface Module Page 10 of 103 ProSoft Technology, Inc. May 29, 2007 2 Open the File menu, and then choose New Project. This action opens the PLC Configuration dialog box. 3 In tIn the list of options on the left side of this dialog box, double-click the PLC Selection folder. This action opens the PLC Selection dialog box. ...

Configuring the Processor with Concept

PTQ-LNG ♦ Quantum / Unity Platform Landis & Gyr Telegyr Interface Module ProSoft Technology, Inc. Page 11 of 103 May 29, 2007 4 In the CPU/Executive pane, use the scroll bar to locate and select the PLC to configure. 5 Click OK. This action opens the PLC Configuration dialog box, populated with the correct values for the PLC you selected. ...

PTQ-LNG ♦ Quantum / Unity Platform

Configuring the Processor with Concept Landis & Gyr Telegyr Interface Module Page 12 of 103 ProSoft Technology, Inc. May 29, 2007 6 Make a note of the holding registers for the module. You will need this information when you modify your application as outlined in the ProTalk Application Reference Guides. The Holding Registers are displayed in the PLC Memory Partition pane of the PLC Configuration dialog box. 2.3 Add the ...

Configuring the Processor with Concept

PTQ-LNG ♦ Quantum / Unity Platform Landis & Gyr Telegyr Interface Module ProSoft Technology, Inc. Page 13 of 103 May 29, 2007 2 Click the Edit button to open the Local Quantum Drop dialog box. This dialog box is where you identify rack and slot locations. 3 Click the Module button next to the rack/slot position where the ProTalk module will be installed. This action opens the I/O Module Selection dialog box. ...

PTQ-LNG ♦ Quantum / Unity Platform

Configuring the Processor with Concept Landis & Gyr Telegyr Interface Module Page 14 of 103 ProSoft Technology, Inc. May 29, 2007 4 In the Modules pane, use the scroll bar to locate and select the ProTalk module, and then click OK. This action copies the description of the ProTalk module next to the assigned rack and slot number of the Local Quantum Drop dialog box. 5 Repeat steps 3 through 5 for each ProTalk module you ...

Configuring the Processor with Concept

PTQ-LNG ♦ Quantum / Unity Platform Landis & Gyr Telegyr Interface Module ProSoft Technology, Inc. Page 15 of 103 May 29, 2007 2.4 Set up Data Memory in Project 1 In the list of options on the left side of the PLC Configuration dialog box, double-click Specials. 2 This action opens the Specials dialog box. ...

PTQ-LNG ♦ Quantum / Unity Platform

Configuring the Processor with Concept Landis & Gyr Telegyr Interface Module Page 16 of 103 ProSoft Technology, Inc. May 29, 2007 Selecting the Time of Day 3 Select (check) the Time of Day box, and then enter the value 00001 as shown in the following example. This value sets the first time of day register to 400001. 4 Click OK to save your settings and close the Specials dialog box. Saving your project 5 In the PLC Conf ...

Configuring the Processor with Concept

PTQ-LNG ♦ Quantum / Unity Platform Landis & Gyr Telegyr Interface Module ProSoft Technology, Inc. Page 17 of 103 May 29, 2007 6 This action opens the Save Project As dialog box. 7 Name the project, and then click OK to save the project to a file. 2.5 Download the Project to the Processor The next step is to download (copy) the project file to the Quantum Processor. 1 Use the null modem cable to connect your PC's ser ...

PTQ-LNG ♦ Quantum / Unity Platform

Configuring the Processor with Concept Landis & Gyr Telegyr Interface Module Page 18 of 103 ProSoft Technology, Inc. May 29, 2007 3 In the PLC Configuration dialog box, open the Online menu, and then choose Connect. This action opens the Connect to PLC dialog box. 4 Leave the default settings as shown and click OK. Note: Click OK to dismiss any message boxes that appear during the connection process. 5 In the PLC Config ...

Configuring the Processor with Concept

PTQ-LNG ♦ Quantum / Unity Platform Landis & Gyr Telegyr Interface Module ProSoft Technology, Inc. Page 19 of 103 May 29, 2007 6 Click All, and then click Download. If a message box appears indicating that the controller is running, click Yes to shut down the controller. The Download Controller dialog box displays the status of the download as shown in the following illustration. 7 When the download is complete, you ...

PTQ-LNG ♦ Quantum / Unity Platform

Configuring the Processor with Concept Landis & Gyr Telegyr Interface Module Page 20 of 103 ProSoft Technology, Inc. May 29, 2007 1 In the PLC Configuration window, open the Online menu, and then choose Online Control Panel. This action opens the Online Control Panel dialog box. 2 Click the Set Clock button to open the Set Controller's Time of Day Clock dialog box. 3 Click the Write Panel button. This action updates the ...