Superior SSDV-3328 Installation Instructions Manual
Text of the manual
P/N 700,043M REV. a 06/2008
DIRECT VENT GAS FIREPLACE HEATERS
DIRECT VENT
SSDV-3328 SERIES
SSDVT-3328CNM
SSDVR-3328CNM
A French manual is available upon request. Order P/N 700,043CF
Ce manuel d’installation est disponible en francais, simplement en
faire la demande. Numéro de la piè
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
TABLE OF CONTENTS
Packaging..........................................Page 2
Introduction.......................................Page 2
General Information...........................Page 2
Requirements for the
Commonwealth of Massachusetts..Page 4
New York City Approval......................Page 4
Cold Cli
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
These appliances and their individual shut-off
valves must be disconnected from the gas
supply piping system during any pressure
testing of that system at pressures greater
than 1/2 psig (3.5 kPa).
These appliances must be isolated from the
gas supply piping system (by closing their
individual manual shut-off va
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
NEW YORK CITY, NY AND MASSA-
CHUSETTS REQUIREMENTS
These appliances are approved for instal-
lation in the following USA locations listed
in the following:
Massachusetts -
Installation of these fireplaces are ap-
proved for installation in the US state of
Massachusetts if the following additional
requirements
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
Cold Climate Insulation
For cold climate installations, seal all cracks
around the appliance with noncombustible
material and wherever cold air could enter
the room. It is especially important to insulate
outside chase cavity between studs and under
floor on which the appliance rests, if floor is
above ground le
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
Figure 4 - Typical Locations
MANUFACTURED HOME
REQUIREMENTS
This appliance may be installed in an after-
market permanently located, manufactured
home (USA only) or mobile home, where not
prohibited by local codes.
Cet appareil peut être installé dans un maison
préfabriquée (É.-U. seulement) ou mobile déj
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
The vent / air intake termination clearances
above the high side of an angled roof is as
shown in the following chart:
12
X
Roof Pitch is X/12
2 FT
MIN.
2 FT MIN.
Lowest
Discharge
Opening
H*
*H = MINIMUM HEIGHT FROM ROOF TO
LOWEST DISCHARGE OPENING OF VENT
TERMINATION HEIGHTS FOR VENTS ABOVE
FLAT OR SLOPED ROOFS
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
Figure 7
V
V
V
V
V
F
C
Fixed
Closed
Window
Operable
Window
B
B
A
B
H
M
I
= Area where Termination is not Permitted
= Air Supply Inlet
X
= Vent Termination
V
D
V
3 ft.
3 ft.
A
A
A = 9 in U.S.
= 12 in Canada
V
L
B
J
X
V
A
G
Inside
Corner Detail
B
C
C
C
*18
Ventilated Soffit
Horizontal
Termination
Detail D
Exteri
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
Combustible materials may project beyond the sides of the fire-
place opening as long as they are kept within the shaded areas
illustrated here.
Hearth Extension - A hearth extension is not required with this appliance. If a hearth extension is
used, do not block the lower control compartment door. Any hearth e