Inogen One G3 Operation & User’s Manual
Read Online
Read the Inogen One G3 Operation & User’s Manual online using the built-in PDF viewer.
Key Pages of Document
Chapter 2 3 Description of the Inogen One® G3 Oxygen Concentrator 3 Important Parts of the Inogen One® G3 Oxygen Concentrator 4 User Interfaces 5 Input / Output Connections 6 Power Supply Options 8 Inogen One® G3 Accessories Chapter 3 11 Operating Instructions 11 General Instructions 15 Additional Operating Instructions 18 Battery Operating Instructions 19 Battery Care and Ma ...
and General Precautions Intended Use, Contraindications and General Precautions Chapter 1 Intended Use The Inogen One® G3 Oxygen Concentrator is used on a prescriptive basis by patients requiring supplemental oxygen. It supplies a high concentration of oxygen and is used with a nasal cannula to channel oxygen from the concentrator to the patient. The Inogen One® G3 may be used in home, institution, vehicle, on an air ...
CAUTION Under certain circumstances, the use of non-prescribed oxygen therapy can be hazardous. This device should be used only when prescribed by a physician. CAUTION Additional monitoring or attention may be required for patients using this device who are unable to hear or see alarms or communicate discomfort. If the patient shows any signs of discomfort, ...
Description of the Inogen One® G3 Oxygen Concentrator 2 On/Off Button Display Back- light Button Breath Detection Light Display Audible Alarm Button Alert/Alarm Light Flow Control Description of the Inogen One® G3 Oxygen Concentrator Chapter 2 English Description of the Inogen One® G3 Oxygen Concentrator Chapter 2 ...
Press once to turn “ON”; Press and hold for one second to turn “OFF”. Audible Alarm Button Pressing this button will toggle the Inogen One® G3’s breath detection audible alert on and off: 1. Default Mode. When the Inogen One® G3 is powered up, the breath detection audible alert is disabled. The display’s mode indication area will show a bell icon crossed out with an X in default mode. 2. Breath Detection Aler ...
User Interfaces (continued) Indicator Lights A red light indicates either a change in operating status or a condition that may need response (alarm). A flashing light is higher priority than non-flashing. Audible Signals An audible signal (beep) indicates either a change in operating status or a condition that may need response (alarm). More frequent beeps indicate higher priority condit ...
Single and Double Rechargeable Lithium Ion Batteries The battery will power the Inogen One® G3 without connection to an external power source. When fully charged, a single battery will provide up to 4 hours of operation; a double battery will provide up to 8 hours of operation. The battery recharges when properly installed in the Inogen One® G3 and the concentrator is connected to AC or DC power. Recharging time is up to 4 hours fo ...
English * Actual product appearance may vary. AC Power Plug* Power Output Plug (Plug into Concentrator) LED Indicator Light* AC Input Inogen One AC Power Supply Model# BA-301 Inogen One G3 DC Power Cable Model# BA-306 DC cigarette lighter Power Plug for use in Automobile/RV/ Boat/Aircraft Power Output Plug (Plug into Concentrator) WARNING Do not use power supplies or power cables other ...
WARNING Do not use power supplies/adapters or accessories other than those specified in this user manual. The use of non-specified accessories may create a safety hazard and/or impair equipment performance. Nasal Cannula A nasal cannula must be used with the Inogen One® G3 to provide oxygen from the concentrator. A single lumen cannula up to 25 feet in length is recommended to ensure proper breath detection and oxygen deli ...
External Battery Charger (BA-303) 1. Plug the External Battery Charger AC power supply cord into an electrical outlet. 2. Plug the External Battery Charger AC power supply into the battery charger. 3. Slide your charger onto the Inogen One G3 Battery by clicking and locking into the charger. 4. When the battery is in the correct position, a solid red light will indicate that the battery is charging. 5. When the gre ...
English Operating Instructions 3 ! C Exhaust General Instructions 1. Place the Inogen One® G3 in a well ventilated location. Air intake and exhaust must have clear access. Locate the Inogen One® G3 in such a way that any auditory alarms may be heard. WARNING Avoid use of the Inogen One® G3 in presence of pollutants, smoke or fumes. Do not use the Inogen One® G3 in presence of flammable anesthetics, cleaning agen ...
of a planned or unexpected loss of the AC or DC external power supply. When operating the Inogen One® G3 from an AC or DC external power supply, a properly inserted Inogen One® G3 battery should be maintained in the unit. This procedure will ensure uninterrupted operation and will operate all alarms and alerts in the event of a loss of the external power supply. 4. Co ...
NOTE When the power supply is disconnected from the AC outlet, also disconnect it from the concentrator to avoid unnecessary battery discharge. 5. Connect the nasal cannula tubing to the nozzle fitting. Nozzle fitting is located on the top of the Inogen One® G3. Use of a single lumen cannula up to 25 feet in length is recommended to ensure proper breath detection and oxygen delivery. Additional titration may be need ...
The Inogen One® G3 will sense the onset of inhalation and deliver a burst of oxygen at a precise time when you inhale. The Inogen One® G3 will sense each breath and continue to deliver oxygen in this manner. As your breathing rate changes, the Inogen One® G3 will sense these changes and deliver oxygen only as you need it. At times, if you inhale very quickly between brea ...
Additional Operating Instructions For Use In Home with AC Power For operation of the power supply using an AC power source, follow these instructions: 1. Connect the AC input to the power supply. 2. Connect the AC power plug to the power source and connect the power output plug to the Inogen One® G3. The green LED will be illuminated, indicating the power supply has input power. Traveling with your Inogen One® G3 Sys ...
An icon of a battery with a lightning bolt or an AC power plug will be displayed on the screen, indicating that external power is connected and functioning properly. WARNING Ensure that the automobile power socket is adequately fused for the Inogen One® G3 power requirements (minimum 15 Amp). If the power socket cannot support a 15 Amp load, the fuse may blow ...