Halstead BFF80 Instructions For Use Installation And Servicing

Text of the manual

Balanced Fanned Flue Boiler

This is a Cat I2H Appliance Reference in these instructions to British Standards and Statutory Regulations/Requirements apply only to the United Kingdom. For Ireland the rules in force must be used. The instructions consist of three parts, User, Installation and Servicing Instructions, which includes the Guarant

TESTING AND CERTIFICATION

This boiler is tested and certificated for safety and performance. It is therefore important that no alteration is made to the boiler, without permission, in writing, from Halstead Boilers Ltd. Any alteration not approved by Halstead Boilers Ltd., could invalidate the certification, boiler warranty and may also infringe

Instructions for Use

Introduction Please read these instructions and follow them carefully for the safe and economical use of your boiler. The Halstead Buckingham 4 B FF series are balanced fanned flue boilers. They provide heating and if required, an indirect domestic hot water supply. The boiler is automatic in operation, having only one user co

To Turn the Appliance On

Turn the electrical supply on to the boiler and check that all remote controls are calling for heat. Turn the boiler temperature control clockwise to any position between “0” and "Max", see diagram 1. "Max" is approximately 82°C (180°F). The boiler lighting operation is now automatic as follows: The fan operates and a

1 General Data

Important Notice This boiler is for use only on G20 gas. The boiler is delivered in one pack and the flue pack is supplied separately. Wherever possible, all materials, appliances and components to be used shall comply with the requirements of applicable British Standards. Where no British Standard exists, materials and equipment sho

1.3 Statutory Requirements

The installation of this appliance must be carried out by a competent person and must be in accordance with the relevant requirements of the current issue of: Manufacturer’s instructions supplied. The Gas Safety (Installation and Use) Regulations, Building Regulations, Local Water Company Bye-laws, The Building Standar

1 General Data

1.7 Boiler Location This boiler is not suitable for outside installation. The boiler casing can be fitted at two heights. Refer to diagram 1.3. The boiler is assembled at the factory with the control box and heat shield fitted in the lower position. The boiler must stand on a level floor, conforming with local authority requirements

FULLY PUMPED SYSTEM

(DIAGRAMMATIC) 2 Water Systems 0870 1 metre MIN. 27metres MAX. PUMP Heating Circuit TO INDIRECT CYLINDER 22mm VENT 15mm COLD FEED Distributor tube in pumped return connection BOILER CL DRAIN OFF COCK 2.1 Water Pressure Head The boiler shall only be connected to a cistern water supply with a minimum head of 1met

3 Flue and Ventilation

FROM OUTSIDE COMPARTMENT AIR VENT TABLE COMPARTMENT VENTILATION REQUIREMENTS VENTILATION FROM ROOM OR SPACE HIGH LEVEL LOW LEVEL VENT AREA VENT AREA The flue must be installed in accordance with the rules in force in the countries of destination. 3.1 Terminal Position The minimum acceptable siting dimensions for the terminal

General Installation Notes

The appliance pack contains :- Boiler Fan connector Casing panels, packed seperately. Loose items fittings pack, see list in pack. The flue is supplied seperately. NOTE: The rear flue option kit Part No. 425861 is available, which consists of wall cover plates, for replacement Buckingham balanced flue

More Halstead Boiler Owners Instructions: