Rega Ios Manual
Text of Rega Ios Manual
Contents
Introduction..............................................................................1
Design Innovation.................................................................2-3
Installation................................................................................3
Ventilation................................................................................4
Connections...........................................................................
The function of a phono pre amplifier is to match the output
from a pick up cartridge to the input of a line level amplifier. It
is required to amplify the very low signals produced by the
cartridge and also to equalise the in accordance with RIAA
record cutting standard.
Rega believes that moving coil and moving magnet cartridges
require different types of phono pre amplifiers to achieve
optimum performance.
The Ios is therefore dedicated
The Rega Ios is a four stage all symmetrical amplifier. To
provide optimum performance it is dedicated to amplifying the
very low level signals that are generated by moving coil
cartridges.
The first stage uses a 1:10 step-up transformer, which can be
optimised to the cartridge by the selection of the correct
loading and zobel DC resistance correction network connected
across the MC transformer secondary.
The second stage is symmetrical
The power supply is a symmetrical discrete tracking power
supply using fast diodes and a low noise voltage reference.
Each stage has it’s own localised power supply, and LED
referenced current generators.
Very high quality, polyproplene capacitors have been used in
the signal path. 1% tolerance polypropylene capacitors are
used in the RIAA EQ stages and audio grade capacitors are
used in the rest of the circuit.
Installation
Ios will work well on most
The heat produced by the amplifier, although minimal, is
dispersed to the air by the case, particularly the underside.
Ensure that the case has an uninterrupted air passage around
it.
Connections
The inputs and outputs are made via RCA (phono) type
connectors. The input and output sockets are marked by colour
to indicate left and right channels, Black for LEFT and Red for
RIGHT.
If your turntable has a separate Earth wire, firmly connect it
The Ios uses a Class I earth system, where the case metal
work and earth screen between the primary and secondary
windings in the toroidal transformer, are connected to the line
safety earth, by means of the mains lead.
The internal signal earth is linked to this earth by the use of a
network to eliminate the risk of earth/ground loops.
This earthing method provides a safe and efficient discharge
path for any static charge generated by the cartr
The Ios phono pre amplifier is not suitable for use with any
Moving Magnet (MM) cartridges, it can only be used with
moving coil (MC) cartridges.
The Ios has been designed to work with most manufacturers
moving coil (MC) cartridges.
There are five different input load settings, select the required
load to match to that specified by the cartridge manufacturer.
The Ios has five different DC resistance settings 1-5.
Note: It is permissib
Ios is activated by depressing the On/Off button situated to the
left of the control panel. The power indicator LED will glow
steadily.
Always activate Ios before the power amplifiers and de-
activate after they have been switched off.
After switching off, the indicator will extinguish.
Due to the nature of the circuit topology, there is a short period
immediately after switching on when the quiescent current has
not stabilised. This conditio
The Load Switch
The DC resistance of the cartridge affects the transient or
square wave response of the transformer; this network has to
be optimised to get the best out of the cartridge and
transformer combination.
There are five different input load settings of 50, 100, 150, 300
& 400Ω. Select the required load to match to that specified by
the manufacturer in the cartridge specifications. It is
permissible to try different loading condition