BK Precision 9110 Operation & User’s Manual

Text of the manual

2 Safety  Summary The  following  safety  precautions  apply  to  both  operating  and  maintenance  personnel  and  must  be followed  during  all  phases  of  operation,  service,  and  repair  of  this  instrument. Before  applying  power  to  this  instrument: • Read  and  understand  the  safety  and  operational  information  in  this  manual. • Apply  all  the  listed  safety  precautions. • Verify  that  the  voltage  selector  at  the  line  power  cord  input  is  set  to  the  correct  line voltage.  Operating  the  instrument  at  an  incorrect  line  voltage  will  void  the  warranty. • Make  all  connections  to  the  instrument  before  applying  power. • Do  not  operate  the  instrument  in  ways  not  specified  by  this  manual  or  by  B&K  Precision. Failure  to  comply  with  these  precautions  or  with  warnings  elsewhere  in  this  manual  violates  the  safety standards  of  design,  manufacture,  and  intended  use  of  the  instrument.  B&K  Precision  assumes  no liability  for  a  customer’s  failure  to  comply  with  these  requirements. Category  rating The  IEC  61010  standard  defines  safety  category  ratings  that  specify  the  amount  of  electrical  energy available  and  the  voltage  impulses  that  may  occur  on  electrical  conductors  associated  with  these category  ratings.  The  category  rating  is  a  Roman  numeral  of  I,  II,  III,  or  IV.  This  rating  is  also  accompanied by  a  maximum  voltage  of  the  circuit  to  be  tested,  which  defines  the  voltage  impulses  expected  and required  insulation  clearances.  These  categories  are: Category  I  (CAT  I):  Measurement  instruments  whose  measurement  inputs  are  not  intended  to  be connected  to  the  mains  supply.  The  voltages  in  the  environment  are  typically  derived  from  a  limited-­‐ energy  transformer  or  a  battery. Category  II  (CAT  II):  Measurement  instruments  whose  measurement  inputs  are  meant  to  be  connected to  the  mains  supply  at  a  standard  wall  outlet  or  similar  sources.  Example  measurement  environments are  portable  tools  and  household  appliances. Category  III  (CAT  III):  Measurement  instruments  whose  measurement  inputs  are  meant  to  be  connected to  the  mains  installation  of  a  building.  Examples  are  measurements  inside  a  building's  circuit  breaker panel  or  the  wiring  of  permanently-­‐installed  motors. Category  IV  (CAT  IV):  Measurement  instruments  whose  measurement  inputs  are  meant  to  be  connected

3 to  the  primary  power  entering  a  building  or  other  outdoor  wiring. Do  not  use  this  instrument  in  an  electrical  environment  with  a  higher  category  rating  than  what  is specified  in  this  manual  for  this  instrument. You  must  ensure  that  each  accessory  you  use  with  this  instrument  has  a  category  rating  equal  to  or higher  than  the  instrument's  category  rating  to  maintain  the  instrument's  category  rating.  Failure  to  do so  will  lower  the  category  rating  of  the  measuring  system. Electrical  Power This  instrument  is  intended  to  be  powered  from  a  CATEGORY  II  mains  power  environment.  The  mains power  should  be  120  V  RMS  or  240  V  RMS.  Use  only  the  power  cord  supplied  with  the  instrument  and ensure  it  is  appropriate  for  your  country  of  use. Ground  the  Instrument To  minimize  shock  hazard,  the  instrument  chassis  and  cabinet  must  be  connected  to  an  electrical  safety ground.  This  instrument  is  grounded  through  the  ground  conductor  of  the  supplied,  three-­‐conductor  AC line  power  cable.  The  power  cable  must  be  plugged  into  an  approved  three-­‐conductor  electrical  outlet. The  power  jack  and  mating  plug  of  the  power  cable  meet  IEC  safety  standards. Do  not  alter  or  defeat  the  ground  connection.  Without  the  safety  ground  connection,  all  accessible conductive  parts  (including  control  knobs)  may  provide  an  electric  shock.  Failure  to  use  a  properly-­‐ grounded  approved  outlet  and  the  recommended  three-­‐conductor  AC  line  power  cable  may  result  in injury  or  death. Unless  otherwise  stated,  a  ground  connection  on  the  instrument's  front  or  rear  panel  is  for  a  reference of  potential  only  and  is  not  to  be  used  as  a  safety  ground. Do  not  operate  in  an  explosive  or  flammable  atmosphere

4 Do  not  operate  the  instrument  in  the  presence  of  flammable  gases  or  vapors,  fumes,  or  finely-­‐divided particulates. The  instrument  is  designed  to  be  used  in  office-­‐type  indoor  environments.  Do  not  operate  the instrument • In  the  presence  of  noxious,  corrosive,  or  flammable  fumes,  gases,  vapors,  chemicals,  or finely-­‐divided  particulates. • In  relative  humidity  conditions  outside  the  instrument's  specifications. • In  environments  where  there  is  a  danger  of  any  liquid  being  spilled  on  the  instrument  or where  any  liquid  can  condense  on  the  instrument. • In  air  temperatures  exceeding  the  specified  operating  temperatures. • In  atmospheric  pressures  outside  the  specified  altitude  limits  or  where  the  surrounding gas  is  not  air. • In  environments  with  restricted  cooling  air  flow,  even  if  the  air  temperatures  are  within specifications. • In  direct  sunlight. This  instrument  is  intended  to  be  used  in  an  indoor  pollution  degree  2  environment.  The  operating temperature  range  is  0  °C  to  40  °C  and  the  operating  humidity  range  is  ≤  80%  relative  humidity  with  no condensation  allowed. Measurements  made  by  this  instrument  may  be  outside  specifications  if  the  instrument  is  used  in  non-­‐ office-­‐type  environments.  Such  environments  may  include  rapid  temperature  or  humidity  changes, sunlight,  vibration  and/or  mechanical  shocks,  acoustic  noise,  electrical  noise,  strong  electric  fields,  or strong  magnetic  fields. Do  not  operate  instrument  if  damaged If  the  instrument  is  damaged,  appears  to  be  damaged,  or  if  any  liquid,  chemical,  or  other  material  gets on  or  inside  the  instrument,  remove  the  instrument's  power  cord,  remove  the  instrument  from  service, label  it  as  not  to  be  operated,  and  return  the  instrument  to  B&K  Precision  for  repair.  Notify  B&K Precision  of  the  nature  of  any  contamination  of  the  instrument. Clean  the  instrument  only  as  instructed

5 Do  not  clean  the  instrument,  its  switches,  or  its  terminals  with  contact  cleaners,  abrasives,  lubricants, solvents,  acids/bases,  or  other  such  chemicals.  Clean  the  instrument  only  with  a  clean  dry  lint-­‐free  cloth or  as  instructed  in  this  manual. Not  for  critical  applications This  instrument  is  not  authorized  for  use  in  contact  with  the  human  body  or  for  use  as  a  component  in  a life-­‐support  device  or  system. Do  not  touch  live  circuits Instrument  covers  must  not  be  removed  by  operating  personnel.  Component  replacement  and  internal adjustments  must  be  made  by  qualified  service-­‐trained  maintenance  personnel  who  are  aware  of  the hazards  involved  when  the  instrument's  covers  and  shields  are  removed.  Under  certain  conditions,  even with  the  power  cord  removed,  dangerous  voltages  may  exist  when  the  covers  are  removed.  To  avoid injuries,  always  disconnect  the  power  cord  from  the  instrument,  disconnect  all  other  connections  (for example,  test  leads,  computer  interface  cables,  etc.),  discharge  all  circuits,  and  verify  there  are  no hazardous  voltages  present  on  any  conductors  by  measurements  with  a  properly-­‐operating  voltage-­‐ sensing  device  before  touching  any  internal  parts.  Verify  the  voltage-­‐sensing  device  is  working  properly before  and  after  making  the  measurements  by  testing  with  known-­‐operating  voltage  sources  and  test for  both  DC  and  AC  voltages.  Do  not  attempt  any  service  or  adjustment  unless  another  person  capable of  rendering  first  aid  and  resuscitation  is  present. Do  not  insert  any  object  into  an  instrument's  ventilation  openings  or  other  openings. Hazardous  voltages  may  be  present  in  unexpected  locations  in  circuitry  being  tested  when  a  fault condition  in  the  circuit  exists. Fuse  replacement Fuse  replacement  must  be  done  by  qualified  service-­‐trained  maintenance  personnel  who  are  aware  of the  instrument's  fuse  requirements  and  safe  replacement  procedures.  Disconnect  the  instrument  from the  power  line  before  replacing  fuses.  Replace  fuses  only  with  new  fuses  of  the  fuse  types,  voltage

Other Power Supply Manuals