Centurion R3 Installation Manual

Text of the manual

Centurion Systems (Pty) Ltd. reserves the right to make changes to the products described in this manual without notice and without

obligation of Centurion Systems (Pty) Ltd. to notify any persons of any such revisions or changes. Additionally, Centurion Systems (Pty) Ltd. makes no representations or warranties with respect to this manual. No part of

Table of Contents

Table of Contents Declaration of Conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Important Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Fast Track . . . . . . . . . .

Declaration of Conformity

Declaration of Conformity Page 4 Manufacturer: Centurion Systems (Pty) Ltd 148 Epsom Road North Riding Gauteng South Africa Declares that the product: Product Name: R3 Swing Gate Operator Product Options: All variants Conforms with the following specifications: Safety: IEC 60355-1:1991 & Am1:1994 & Am2:1999 Emissions: CISPR 22 CLASS

Important Safety Instructions

Important Safety Instructions To ensure the safety of people, it is important that you read all the following instructions. Incorrect installation or incorrect use of the product could cause serious harm to people. ATTENTION The installer, being either professional or DIY, is the last person on the site that can ensure that the

These abbreviated instructions are for the experienced installer who needs a checklist to get a

standard installation up and running in the minimum of time. Detailed installation features and functions are referred to later in this manual. Fast Track Fast Track Action Mechanical Setup Read and understand all safety instructions Page 5 Gather required tools a

The R3 & R5 rotary swing gate systems are designed to open and close swing gates. The CP75 controller

is capable of handling both single and double swing gates and offers many features to suit almost any application. Detailed specifications for the R3 & R5 motors are shown in the figure below and the table alongside. The unit employs a battery driven DC mot

Connect all wiring:

Page 27 Set the gate origin: Page 27 Release the manual override and close the gate(s) Use origin tool and line up marks Open gate ½ way and unscrew the manual release mechanism. Get into programming mode: Page 28 Remove all power. Fit the SET link. Reapply power. Select master or slave set-up: Page 29 Press and hold TEST, release after

220V AC ±10% 50Hz

AC Current draw (with C84E Battery Charger) 120mA 120mA DC Motor Voltage 12V 12V DC Current draw (Max) 30A 35A Maximum solenoid lock current draw 2A 2A Output shaft rotational speed 3.5 rpm 2.6 rpm Maximum output torque 95Nm 250Nm Mass of master motor kit (excluding pedestal or wall bracket) 14.4kg 15,5kg

The actual components supplied may vary depending on the model purchased.

Product Identification Product Identification Figure 2 Linkage Hardware Kit 1 Page 10 1. R3/R5 Linkage Hardware Kit 2. Connecting Arm 3. Drive Arm 4. End Cap 5. Drive Arm Clamp 6. Wedge 7. M10 Washer 8. M12x65 Bolt 9. Clevis Pin 10. Gate Bracket 11. Padlock wi