Harvest-Master Climate Manual
Text of the manual
• Climate Pro (with CO2 sensor)
• Climate Plus
• Pro Plus (with CO2 sensor)
Table of Contents
Introduction
pg 3
Contents of Pack
pg 4
Harvest-Master Connections
pg 6
Harvest-Master Plug and Run
pg 8
Set-up Equipment
pg 10
Set-up Climate Information
pg 11
Set-up Growth Cycle
pg 14
Set-up Outputs on Plus model only
pg 16
Hints on Setting up Greenhouse
pg 19
Equipment for your Greenhouse
pg 20
Electrical Safety
pg 21
W
Harvest-Master Climate Controllers
In four models
•
Climate (without CO2)
•
Climate Pro
•
Climate Plus (expanded input/output)
(modem “talk to me” option available (without CO2)
•
Pro Plus c/w CO2 (expanded input/output)
(modem “talk to me” option available
•
I t
Contents of Pack
Your Harvest-master Climate controller is manufactured using the highest
quality components, by a team of specialists, to suit the demands of a
working horticultural environment. There are no user serviceable parts
inside. If the unit fails for any reason, return it to your supplier or directly
to Harvest-Master for a no questions replace
RS232 port (DB9)
Power input 12vDC x .1amp (12 watts)
Aux connector (RJ12).
Outputs (RCA): 0.1A Max. Inputs 0.1A max (RCA).
Fuse 1A Blade type.
16 Character x2 line backlit LCD.
LED indicators for power, sensor, output line status (On/Off).
Climate and Pro models; 8 outputs for “switch on demand” or “cycle timer”.
Pro
Plug & Run.
Locating Harvest-Master.
Harvest-Master is best fitted outside your Green House (only inside it if conditions are dry and no
condensing humidity). Harvest-Master will need to be physically located so that the 10-ft (3 metre)
control cables will reach from Harvest-Master to where you connect remote relay switches. Switch
relays can be located
Powering Harvest-Master for the First Time
Now it is time to power it all up. Turn on the power to all of the devices you have connected and then
power ON the Harvest-Master. Now Harvest Master will perform Room Calibration.
1)
SET CLOCK. At first power up, it will prompt you to set the clock. Adjust the time with the
arrow keys then press OK, or Press �
1) Types of devices supported are:
a) Lights
b) Fans
c) More Fans
d) Watering
e) Heat
f) Cool
g) Humidify
h) Dehumidify
i) CO2
j) Alarm
2)
Additional points to note:
a)
If you have two sets of lights running, you can install both on one output using a standard
RCA "Y" connector to control both relay units. This also applies to using one device from 2
outp