Blue Seal E26 Service Manual
Text of the manual
WARNING: ALL INSTALLATION AND SERVICE REPAIR WORK MUST BE CARRIED
OUT BY QUALIFIED PERSONS ONLY.
This manual is designed to take a more in depth look at the E26 convection oven for the purpose of
making the unit more understandable to service people.
There are settings explained in this manual that should never require to be adjusted, but for
completeness and those special cases where these settings are required to change,
- Electrical connection entry point
Dimensions shown in millimetres.
Dimensions in inches shown in brackets.
885
(34.9)
179
(7.0)
430
(16.9)
45
(1.75)
395
(15.5)
124
(4.9)
791
(31.1)
668
(26.3)
To ensure correct ventilation for the motor and
controls the following minimum installation
clearances are to be adhered to:
Rear 25mm / 1”
Left-hand side 25mm / 1”
Right-hand side 25mm / 1”
OVEN INTERNAL DIMENSIONS
Width 635 mm / 25”
Height 270 m
RATING PLATE LOCATION
The rating plate for the E26 convection oven
is located at the bottom left corner of the RH
side panel.
It is most important that the oven is installed
correctly and that the operation is correct
before use. Installation shall comply with local
electrical, health and safety requirements.
BEFORE
CONNECTION
TO
POWER
3.1 DESCRIPTION OF CONTROLS - E26
1. POWER
Depress to switch power on or off (switch
illuminates when power is on).
2. THERMOSTAT
Temperature range 50 - 250°C.
Light illuminates when elements are cycling
ON to maintain set temperature.
3. BAKE TIMER
1 Hour bake timer.
(Light illuminates when “time up” (0) reached,
and bu
3.2 EXPLANATION OF CONTROL
SYSTEM
The E26 Turbofan convection ovens feature
multi-function operator controls for which a
correct understanding of their operation is
required before carrying out any service or
fault repair work. The control device functions
are explained as follows:
A power switch on the control panel isolates
power