Description and operating instructions

Industrial ETHERNET IP67 Switch The Ethernet switch OCTOPUS 5TX-EEC has been especially designed for use in indu- strial environments. It supports ETHERNET 10 MBit/s and Fast ETHERNET 100 MBit/s. The Ethernet switch modules support swit- ched ETHERNET networks in accordance with IEEE standard 802.3 (10BASE-T) or 802.3u ...

The performance features described here

are binding only if they have been expressly guaranteed in the contract. We have checked that the contents of the technical publication agree with the hardware and software described. However, it is not possi- ble to rule out deviations completely, so we are unable to guarantee complete agree- ment. However, the deta ...

Failure to observe the information

given in the warnings could result in serious injury and/or major damage. Only personnel that have received appropriate training should operate this device or work in its immediate vicinity. The personnel must be fully familiar with all of the warnings and maintenance measures in these operating instructions. C ...

1. Functional description

The 10/100BASE-T(X) ports of an OCTOPUS 5TX-EEC represent a terminal connection for the connected LAN segment. You can connect single devices or complete network segments. 1.1 FRAME SWITCHING FUNCTIONS Store and Forward All data received by the OCTOPUS 5TX-EEC from the system bus or at the ports are sto- red and checked for validi ...

The equipment is delivered in a ready-to-

operate condition. To protect the exposed contacts of the com- ponents still to be installed from dirt, the individual system components must be connected in a dry and clean area. Ports which are not assigned are to be closed with the covering caps contained in the scope of delivery. Note: Connectors a ...

5. Technical data

General data Operating voltage NEC Class 2 power source 9.6 VDC … 32.0 VDC safety extra-low voltage (SELV/PELV) 5 A maximum Buffer time min. 10 ms at 20.4 VDC Potential difference between input Potential difference to input voltage, +24 VDC: 32 VDC voltage and housing Potential difference to input voltage, ground: -32 VDC Current consumpt ...