Xantech 480-95 Installation Instructions Manual

Text of Xantech 480-95 Installation Instructions Manual

- 1 -

INSTALLATION INSTRUCTIONS 480-95 Plasma Friendly Dinky Link IR Receiver DESCRIPTION The 480-95 is a Plasma Friendly version of the 480-00 series Dinky Link IR receivers. It is specifically designed to have greater immunity to plasma infrared inference and to have exceptional IR reception range. Besides showing great immunity to plasma emissions, the 480-95 (as well as all Xantech Plasma-Friendly Receivers) work well in the presence of Sunli

- 2 -

SPECIFICATIONS: INSTALLATION This unit is meant to be interfaced to Xantech Connecting Blocks, such as CB12, 789-44, 791-44, etc. PLACEMENT Placement of the IR Receiver does matter when used in the presence of a Plasma Display. Ideally it should be placed somewhere around the Display with the front of the receiver flush with the front of the Display. If the 480-95 needs to be placed in front of the display (such as on an adjacent side wall

- 3 -

Note: Plasma interference can be reflected off of any item it comes into contact with approx. 3 feet from the front of the display. Keeping this in mind, make sure that the 480-95 is free of any obstruction that might reflect back in to the receiving eye. Note: While this unit shows strong rejection to standard 50/60Hz ‘ballasted’ fluorescent lighting, it is still prone to interference from CFL style Fluorescent lighting. MOUNTING 1. Th

Xantech 480-95 - 4 -

ADVANCED WIRING CONFIGURATION 480-95 may also be used in conjunction with other Xantech IR Receivers by simply wiring in parallel on a Connecting Block such as the 791-44 Amplified Block as shown in the figure below. 1. Connect all IR Receivers in parallel at the terminals of the connecting block as shown in the figure below. 2. Plug in the 2.1mm Coaxial power plug of the 781RG (or 782) Power supply (not included) into the jack labeled PWR

- 5 -

IR Troubleshooting Guide NOTE: Due to the many variables in a given installation, the troubleshooting countermeasures you will have to take may vary from job to job. Each installation is different due to the number of IR receivers in use, length of wire runs, type of wire, amount of ambient IR noise present, etc…. Therefore, your countermeasures for a particular job will range from nothing at all, to any combination of the solutions list

- 6 -

Symptom #2: TB LED on IR Receiver (and/or Emitters) Dimly lit or flickering Cause: Solution 1. Signal and ground wires are reversed or shorted either at the connecting block or IR receiver. Recheck your wiring. 2. Defective emitter. Replace Emitter 3. Relatively high levels of ambient noise. This can be due to any of the following: Sunlight, florescent Lighting or Plasma Displays. In this case use either a SUN filter (SUN480, SUN490, SUN7

Xantech 480-95 - 7 -

Symptom #3: TB LED on IR Receiver (and/or Emitters) on solid Cause: Solution 1. Plasma Interference Use a 490-90 Plasma 'Friendly' Receiver. If already using a 490-90 unit, please note the Plasma interference can be reflected off of any item it comes into contact with within approx. 3ft. From the front of the display. Keeping this in mind, make sure that the 490-90 is free from any obstruction that might reflect back into the receiving eye.

- 8 -

Symptom #4: TB LED on IR Rec. blinks but 283M or 286M 'Blink' style Emitters do not Cause: Solution 1. There may be a short, such as a staple driven through the Signal and GND wires of the IR Receiver and/or the emitter. Recheck your wiring. 2. Emitter may be shorted internally Replace Emitter or use TEST EMITTER to check circuit. 3 (XTRALINK Only) TV on same splitter with no IR Receiver installed Place a DC Blocker (Model 203-00) on any TV

- 9 -

Symptom 6: Emitters function but some (or all) components do not respond. Cause: Solution 1. Emitter placement is incorrect. Reposition the Emitter so that it is directly over the components sensor window. Consult the components owners manual of the unit for the exact location of the IR Sensor Window. 2. Emitter placement is correct but the signal is overpowering the unit or there is bleed- through from other emitters close by. Reposition t

- 10 -

Symptom #7: Absolutely No Functionality (How to determine which component is at fault) Step: Component to Test Instructions 1. Verify Power Supply With a Multimeter, measure the DC Voltage of the supply while it is connected to the Connecting Block. Put the Negative lead of the meter on the terminal marked GND and the Positive Lead on the terminal marked 12VDC (or V). You should get a reading between 11.5VDC and 13.0VDC. If not, remove the

- 11 -

4. Verify IR Receiver. Remove the power supply from the connecting block and all Emitters from the output. Place a jumper wire on the connecting block between IR Signal and GND. Reconnect the Power Supply. With a known good hand-held remote, shoot a constant IR Command at the receiver and verify the TB LED on the Receiver lights. Xantech Corporation 13100 Telfair Avenue, 2/F Sylmar, CA 91342 Phone: (818) 362-0353, Fax: (818) 362-9506 Instr

Xantech Receiver Owners Instructions: