Xantech 480-95 Installation Instructions Manual
Text of Xantech 480-95 Installation Instructions Manual
- 1 -
INSTALLATION INSTRUCTIONS
480-95
Plasma Friendly Dinky Link IR Receiver
DESCRIPTION
The 480-95 is a Plasma Friendly version of the 480-00 series Dinky Link IR receivers. It is specifically
designed to have greater immunity to plasma infrared inference and to have exceptional IR reception
range. Besides showing great immunity to plasma emissions, the 480-95 (as well as all Xantech
Plasma-Friendly Receivers) work well in the presence of Sunli
- 2 -
SPECIFICATIONS:
INSTALLATION
This unit is meant to be interfaced to Xantech Connecting Blocks, such as CB12, 789-44, 791-44, etc.
PLACEMENT
Placement of the IR Receiver does matter when used in the presence of a Plasma Display. Ideally it
should be placed somewhere around the Display with the front of the receiver flush with the front of
the Display. If the 480-95 needs to be placed in front of the display (such as on an adjacent side wall
- 3 -
Note: Plasma interference can be reflected off of any item it comes into contact with approx. 3 feet
from the front of the display. Keeping this in mind, make sure that the 480-95 is free of any
obstruction that might reflect back in to the receiving eye.
Note: While this unit shows strong rejection to standard 50/60Hz ‘ballasted’ fluorescent lighting, it is
still prone to interference from CFL style Fluorescent lighting.
MOUNTING
1. Th
Xantech 480-95 - 4 -
ADVANCED WIRING CONFIGURATION
480-95 may also be used in conjunction with other Xantech IR Receivers by simply wiring in parallel
on a Connecting Block such as the 791-44 Amplified Block as shown in the figure below.
1. Connect all IR Receivers in parallel at the terminals of the connecting block as shown in the
figure below.
2. Plug in the 2.1mm Coaxial power plug of the 781RG (or 782) Power supply (not included) into
the jack labeled PWR
- 5 -
IR Troubleshooting Guide
NOTE: Due to the many variables in a given installation, the troubleshooting countermeasures you will
have to take may vary from job to job. Each installation is different due to the number of IR receivers in
use, length of wire runs, type of wire, amount of ambient IR noise present, etc…. Therefore, your
countermeasures for a particular job will range from nothing at all, to any combination of the solutions list
- 6 -
Symptom #2: TB LED on IR Receiver (and/or Emitters) Dimly lit or flickering
Cause:
Solution
1.
Signal and ground wires are reversed or
shorted either at the connecting block or IR
receiver.
Recheck your wiring.
2. Defective emitter.
Replace Emitter
3.
Relatively high levels of ambient noise. This
can be due to any of the following: Sunlight,
florescent Lighting or Plasma Displays.
In this case use either a SUN filter
(SUN480, SUN490, SUN7
Xantech 480-95 - 7 -
Symptom #3: TB LED on IR Receiver (and/or Emitters) on solid
Cause:
Solution
1.
Plasma Interference
Use a 490-90 Plasma 'Friendly'
Receiver. If already using a 490-90 unit,
please note the Plasma interference can
be reflected off of any item it comes into
contact with within approx. 3ft. From the
front of the display. Keeping this in mind,
make sure that the 490-90 is free from
any obstruction that might reflect back
into the receiving eye.
- 8 -
Symptom #4: TB LED on IR Rec. blinks but 283M or 286M 'Blink' style Emitters do not
Cause:
Solution
1.
There may be a short, such as a staple
driven through the Signal and GND wires of
the IR Receiver and/or the emitter.
Recheck your wiring.
2.
Emitter may be shorted internally
Replace Emitter or use TEST EMITTER
to check circuit.
3
(XTRALINK Only) TV on same splitter with
no IR Receiver installed
Place a DC Blocker (Model 203-00) on
any TV
- 9 -
Symptom 6: Emitters function but some (or all) components do not respond.
Cause:
Solution
1.
Emitter placement is incorrect.
Reposition the Emitter so that it is
directly over the components sensor
window. Consult the components
owners manual of the unit for the exact
location of the IR Sensor Window.
2.
Emitter placement is correct but the signal is
overpowering the unit or there is bleed-
through from other emitters close by.
Reposition t
- 10 -
Symptom #7: Absolutely No Functionality (How to determine which component is at fault)
Step:
Component to Test
Instructions
1.
Verify Power Supply
With a Multimeter, measure the DC
Voltage of the supply while it is
connected to the Connecting Block. Put
the Negative lead of the meter on the
terminal marked GND and the Positive
Lead on the terminal marked 12VDC (or
V). You should get a reading between
11.5VDC and 13.0VDC. If not, remove
the
- 11 -
4.
Verify IR Receiver.
Remove the power supply from the
connecting block and all Emitters from
the output. Place a jumper wire on the
connecting block between IR Signal and
GND. Reconnect the Power Supply.
With a known good hand-held remote,
shoot a constant IR Command at the
receiver and verify the TB LED on the
Receiver lights.
Xantech Corporation
13100 Telfair Avenue, 2/F
Sylmar, CA 91342
Phone: (818) 362-0353, Fax: (818) 362-9506
Instr