Sharp R-1900J Service Manual

Text of Sharp R-1900J Service Manual

CHAPTER 1. BEFORE SERVICING

CHAPTER 2. WARNING TO SERVICE PERSONNEL CHAPTER 3. PRODUCT DESCRIPTION CHAPTER 4. OPERATION CHAPTER 5. TROUBLESHOOTING GUIDE CHAPTER 6. TEST PROCEDURES CHAPTER 7. TOUCH CONTROL PANEL ASSEMBLY CHAPTER 8. PRECAUTIONS FOR USING LEAD- FREE SOLDER CHAPTER 9. COMPONENT REPLACEMENT AND ADJUSTMENT PROCEDURE CHAPTER 10. MICROWAVE MEASUREMENT CHAPTER 11. CIRCUIT DIAGRAMS Parts List S6903R1900PJ/ SERVICE MANUAL R1900J CONTENTS This documen
CHAPTER 1. BEFORE SERVICING CHAPTER 2. WARNING TO SERVICE PERSON- NEL CHAPTER 3. PRODUCT DESCRIPTION [1] SPECIFICATIONS ...................................... 3-1 [2] APPEARANCE VIEW ................................. 3-1 [3] INSTALLATION INFORMATION................. 3-2 CHAPTER 4. OPERATION [1] DESCRIPTION OF OPERATING SE- QUENCE .................................................... 4-1 [2] DESCRIPTION AND FUNCTION OF COMPONENTS ...................

1 – 1

R1900J Servi ce Manual CHAPTER 1. BEFORE SERVICING GENERAL IMPORTANT INFORMATION This Manual has been prepared to provide Sharp Corp. Service engineers with Operation and Service Information. It is recommended that service engineers carefully study the entire text of this manual, so they will be qualified to render satisfactory customer ser- vice. WARNING MICROWAVE RADIATION Personnel should not be exposed to the microwave energy which may

2 – 1

R1900J Servi ce Manual CHAPTER 2. WARNING TO SERVICE PERSONNEL Microwave ovens contain circuitry capable of producing very high voltage and current, contact with any part of the high voltage circuit will result in electrocution. High voltage capacitor, Power transformer, Magnetron, High voltage rectifier assembly, High voltage fuse, High voltage harness. REMEMBER TO CHECK 3D 1) Disconnect the supply. 2) Door opened, and wedged open. 3) Disc

3 – 1

R1900J Servi ce Manual CHAPTER 3. PRODUCT DESCRIPTION [1] SPECIFICATIONS [2] APPEARANCE VIEW 1. OVEN 1. Touch control panels 2. Door latch openings 3. Ceramic shelf 4. Oven lamp 5. Air intake openings 6. Air intake flter 7. Door seals and sealing surfaces 8. Door hinges 9. Oven door with see-through window 10. Door latches 11. Door handle 12. Access cover for replacing the oven lamp 13. Ventilation openings 14. Power supply cord 15. Mountin

3 – 2

2. TOUCH CONTROL PANEL [3] INSTALLATION INFORMATION When this commercial microwave oven is installed near other commercial electrical appliances, connect a lead wire to each equivalent potential ter- minal with equipotential marking between them (insert a lead wire between a washer and an earth angle, and screw them), as shown in Fig. A-1, to make sure that they are at equivalent potential. If any lead wire is not connected between them, whe

4 – 1

R1900J Servi ce Manual CHAPTER 4. OPERATION [1] DESCRIPTION OF OPERATING SEQUENCE The following is a description of component functions during oven operation. 1. OFF CONDITION 1. When the oven is plugged in with the door closed, the line voltage is supplied to the noise filter. And the display shows nothing. (Refer to Figure O-1(a)) 2. When the door is opened with plugged in, the contacts (COM-NC) of the secondary interlock switch (1

4 – 2

[2] DESCRIPTION AND FUNCTION OF COMPONENTS 1. DOOR OPEN MECHANISM 1. The handle lever is pulled. 2. The upper and lower latch heads are lifted up by the linked latch lever. 3. The latch lever is lifted up by the handle lever. 4. Now both latch heads are lifted up, so they can be released from the latch hook. 5. Now the door can be opened. Figure D-1. Door Open Mechanism 2. DOOR SENSING SWITCH The door sensing switch is activated by the latch

4 – 3

10. FAN MOTORS The fan motors drive blades which draw external cool air into the oven. This cool air is directed through the air vanes surrounding the magne- trons and cools the magnetrons. This air is channelled through the oven cavity to remove steam and vapours given off from the heating foods. It is then exhausted through the exhausting air vents at the oven cavity. During cooking, they operate. After cooking, the fan motors will operate

5 – 1

R1900J Servi ce Manual CHAPTER 5. TROUBLESHOOTING GUIDE When troubleshooting the microwave oven, it is helpful to follow the Sequence of Operation in performing the checks. Many of the possible causes of trouble will require that a specific test be performed. These tests are given a procedure letter which will be found in the “Test Procedure“ section. IMPORTANT: If the oven becomes inoperative because of a blown weak point (1) or (2), c

5 – 2

SPECIFICATION OF ERROR Outline Operation when error occurs Display in operation usually When a basic performance and the function are ruined Displaying and heating stop EE0, EE1, EE2, EE3, EE8 When the dangers of the state of the high temperature and the ignition, etc. are foreseen Displaying and heating stop EE7 When you mistake the setting of the heating time Operation stop EE9 When neither the power supply nor the environmental condition

6 – 1

R1900J Servi ce Manual CHAPTER 6. TEST PROCEDURES [1] A: MAGNETRON TEST CARRY OUT 3D CHECKS. Isolate the magnetron from high voltage circuit by removing all leads connected to filament terminal. To test for an open circuit filament use an ohmmeter to make a continuity test between the magnetron filament terminals, the meter should show a reading of less than 1 ohm. To test for short circuit filament to anode condition, connect ohmmeter betw

6 – 2

JUDGEMENT: The measured output power should be at least ± 15% of the rated output power. CAUTION: 1°C CORRESPONDS TO 190WATTS REPEAT MEASUREMENT IF THE POWER IS INSUFFICIENT. [2] B: POWER TRANSFORMER TEST 1. CARRY OUT 3D CHECKS. 2. Disconnect the leads to the primary winding of the power transformer. Disconnect the filament and secondary winding connections from the rest of the HV circuitry. Using an ohmmeter, set on a low range, it is pos

6 – 3

[4] D: HIGH VOLTAGE CAPACITOR (1) AND/OR (2) TEST 1. CARRY OUT 3D CHECKS. 2. If the capacitor is open, no high voltage will be available to the magnetron. Disconnect input leads and check for short or open between the termi- nals using an ohmmeter. Checking with a high ohm scale, if the high voltage capacitor is normal, the meter will indicate continuity for a short time and should indicate an open circuit once the capacitor is charged. If t

6 – 4

[9] I: WEAK POINT (FOR FAN MOTOR) TEST CARRY OUT 3D CHECKS. If the weak point is blown, the fan motor or exhaust fan could be locked or there could be a shorts in the fan motor or exhaust fan. Check them and replace the defective parts. CARRY OUT 4R CHECKS. CAUTION: Only replace weak point with the correct value replacement. [10] J: WEAK POINT (IN NOISE FILTER) TEST CARRY OUT 3D CHECKS. If the weak point is blown, there could be a shorts or

Sharp R-1900J 6 – 5

[14] N: NOISE FILTER TEST 1. CARRY OUT 3D CHECKS. 2. Disconnect the lead wires from the terminal the noise filter. Using an ohmmeter, check between the terminals as described in the following table. If incorrect reading are obtained, replace the noise filter. 3. CARRY OUT 4R CHECKS. [15] O: KEY UNIT TEST 1. CARRY OUT 3D CHECKS. 2. Check Key unit ribbon connection before replacement. 3. If key unit ribbon connection is normal, carry out the f

Sharp R-1900J 6 – 6

[16] P: CONTROL UNIT TEST The following symptoms indicate a defective control unit. Before replacing the control unit, perform the Key units test (Procedure O) to determine if control unit is faulty. Connect the power supply cord. And check for followings. 1. In connection with pads. 1) When touching the pads, a certain group of pads do not produce a signal. 2) When touching the pads, no pads produce a signal. 2. In connection with display 1

Sharp R-1900J 6 – 7

[19] S: ANTENNA SENSOR TEST There is no test procedure for the antenna sensor. When the error history display shows EE15, EE25 or EE35, if the antenna motors, control unit and wiring are normal, the antenna sensor may be defective. [20] T: MICROWAVE SENSOR TEST There is no test procedure for the microwave sensor. When the error history display shows EE18, EE28 or EE38, if the magnetrons, control unit and wiring are normal, the microwave sens

7 – 1

R1900J Servi ce Manual CHAPTER 7. TOUCH CONTROL PANEL ASSEMBLY [1] SPECIAL FUNCTION FOR SERVICING This oven has the special functions for servicing as shown in the table 1 ~ 4. By using the special function, service person can check the using time or the using number of times for the electrical parts. Also service person can check the AC supply voltage and /or set the standard voltage. When “SF-2” is selected, the display will show the

Sharp Microwave Oven Owners Instructions: