Siemens SINAMICS G120D Operating Instructions Manual

File Specifications

Brand: Siemens
Category: Control Unit
Model: SINAMICS G120D (Operating Instructions Manual), prg1t5BVtgM56
File Type: PDF
File Size: —
Pages: 302 pages

Download Document

Get a high-quality, printable PDF version of this manual for offline use.

Download PDF Manual (302 pages)

⚠️ Download Safety: This PDF is completely safe to download (last scan date: 20/07/2026).

Read Online

Read the Siemens SINAMICS G120D Operating Instructions Manual online using the built-in PDF viewer.

Key Pages of Document

Converter with control units CU240D-2

___________________ ___________________ ___________________ ___________________ ___________________ ___________________ ___________________ ___________________ ___________________ ___________________ ___________________ ___________________ ___________________ ___________________ SINAMICS SINAMICS G120D Converter with control units CU240D-2 Operating Instructions Edition 04/2014, Firmware V4.7 Original instructions 04/2 ...

Postfach 48 48

90026 NÜRNBERG GERMANY A5E34262100B AA Ⓟ 06/2014 Subject to change Copyright © Siemens AG 2012 - 2014. All rights reserved Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring ...

Converter with control units CU240D-2

Operating Instructions, 04/2014, FW V4.7, A5E34262100B AA 5 Changes in this manual Important changes with respect to the Manual, 01/2013 Edition New hardware In Chapter New CU240D-2 PN-F FO Control Units with fieldbus via fiber-optic cable SINAMICS G120D CU240D-2 Inverter (Page 23) Connections and cables (Page 37) New Firmware Functions for V4.7 In Chapter Reducing the pulse frequency and increasing the current limit i ...

Changes in this manual

Converter with control units CU240D-2 6 Operating Instructions, 04/2014, FW V4.7, A5E34262100B AA ...

Converter with control units CU240D-2

Operating Instructions, 04/2014, FW V4.7, A5E34262100B AA 7 Table of contents Changes in this manual ........................................................................................................................... 5 1 Fundamental safety instructions ............................................................................................................ 13 1.1 General safety instructions ................. ...

Table of contents

Converter with control units CU240D-2 8 Operating Instructions, 04/2014, FW V4.7, A5E34262100B AA 5.3 Restoring the factory setting ....................................................................................................... 62 5.4 Basic commissioning with IOP .................................................................................................... 64 5.5 Basic commissioning with STARTER ............................. ...

Table of contents

Converter with control units CU240D-2 Operating Instructions, 04/2014, FW V4.7, A5E34262100B AA 9 8.3.3 Specifying the setpoint via the fieldbus ...................................................................................... 115 8.3.4 Motorized potentiometer as setpoint source .............................................................................. 116 8.3.5 Fixed speed as setpoint source ..................................... ...

Table of contents

Converter with control units CU240D-2 10 Operating Instructions, 04/2014, FW V4.7, A5E34262100B AA 8.8.1 Function description .................................................................................................................. 177 8.8.2 Prerequisite for STO use ........................................................................................................... 179 8.8.3 Commissioning STO .............................. ...

Table of contents

Converter with control units CU240D-2 Operating Instructions, 04/2014, FW V4.7, A5E34262100B AA 11 11 Alarms, faults and system messages .................................................................................................. 233 11.1 Alarms ........................................................................................................................................ 233 11.2 Faults ..................................... ...

Table of contents

Converter with control units CU240D-2 12 Operating Instructions, 04/2014, FW V4.7, A5E34262100B AA A.10.3 Product Support ........................................................................................................................ 293 A.10.4 Mistakes and improvements ..................................................................................................... 294 Index .................................................. ...

Converter with control units CU240D-2

Operating Instructions, 04/2014, FW V4.7, A5E34262100B AA 13 Fundamental safety instructions 1 1.1 General safety instructions DANGER Danger to life due to live parts and other energy sources Death or serious injury can result when live parts are touched. • Only work on electrical devices when you are qualified for this job. • Always observe the country-specific safety rules. Generally, six steps apply when establi ...

Fundamental safety instructions

1.1 General safety instructions Converter with control units CU240D-2 14 Operating Instructions, 04/2014, FW V4.7, A5E34262100B AA WARNING Danger to life when live parts are touched on damaged devices Improper handling of devices can cause damage. For damaged devices, hazardous voltages can be present at the enclosure or at exposed components; if touched, this can result in death or severe injury. • Ensure compliance with ...

Fundamental safety instructions

1.1 General safety instructions Converter with control units CU240D-2 Operating Instructions, 04/2014, FW V4.7, A5E34262100B AA 15 WARNING Danger to life through unexpected movement of machines when using mobile wireless devices or mobile phones Using mobile wireless devices or mobile phones with a transmit power > 1 W closer than approx. 2 m to the components may cause the devices to malfunction, influence the functional sa ...

Fundamental safety instructions

1.1 General safety instructions Converter with control units CU240D-2 16 Operating Instructions, 04/2014, FW V4.7, A5E34262100B AA NOTICE Device damage caused by incorrect voltage/insulation tests Incorrect voltage/insulation tests can damage the device. • Before carrying out a voltage/insulation check of the system/machine, disconnect the devices as all converters and motors have been subject to a high voltage test by the ...

Fundamental safety instructions

1.2 Safety instructions for electromagnetic fields (EMF) Converter with control units CU240D-2 Operating Instructions, 04/2014, FW V4.7, A5E34262100B AA 17 1.2 Safety instructions for electromagnetic fields (EMF) WARNING Danger to life from electromagnetic fields Electromagnetic fields (EMF) are generated by the operation of electrical power equipment such as transformers, converters or motors. People with pacemakers or impl ...

Fundamental safety instructions

1.4 Industrial security Converter with control units CU240D-2 18 Operating Instructions, 04/2014, FW V4.7, A5E34262100B AA 1.4 Industrial security Note Industrial security Siemens provides products and solutions with industrial security functions that support the secure operation of plants, solutions, machines, equipment and/or networks. They are important components in a holistic industrial security concept. With this in mi ...

Fundamental safety instructions

1.5 Residual risks of power drive systems Converter with control units CU240D-2 Operating Instructions, 04/2014, FW V4.7, A5E34262100B AA 19 1.5 Residual risks of power drive systems The control and drive components of a drive system are approved for industrial and commercial use in industrial line supplies. Their use in public line supplies requires a different configuration and/or additional measures. These components may ...

Fundamental safety instructions

1.5 Residual risks of power drive systems Converter with control units CU240D-2 20 Operating Instructions, 04/2014, FW V4.7, A5E34262100B AA 3. Hazardous shock voltages caused by, for example, – Component failure – Influence during electrostatic charging – Induction of voltages in moving motors – Operation and/or environmental conditions outside the specification – Condensation/conductive contamination – External ...