Read the YOKOGAWA DLM4000 Series Operation & User’s Manual online using the built-in PDF viewer. This document explains how to operate the device, adjust settings and perform regular maintenance.

Key Pages of Document

Displaying FFT Waveforms

This section explains the following settings (which are used when performing FFT analysis). • FFT waveform display • Analysis source waveform • FFT conditions • Analysis range • Vertical and horizontal scale values • FFT points ► “FFT” in the Features Guide FFT Menu Press SHIFT+MATH/REF (FFT) to display the following menu. Set the number of FFT points. Set the vertical and horizontal scale values. Set the analysis range (Main, Zoom1, Zoom2). Configure the FFT conditions. Set the analysis source waveform (CH1 to CH ...

2.22 Setting the Action-On-Trigger Function

This section explains the following settings (which are used when executing the action-on-trigger function). • Action mode • Action to execute • The number of actions • Action execution ► “Executing Actions” in the Features Guide Action on Trig Menu Press SHIFT+MODE (ACTION GO/NO-GO), the Mode soft key, and the Action on Trig soft key to display the following menu. Set Mode to Action on Trig. Set the number of actions (the number of waveform acquisitions). Executes the action Set the action to execute. Select whethe ...

Setting the Trigger Source (Source)

Press the Source soft key to display one of the menus shown below. The menu that is displayed varies depending on the specified trigger source. When the Trigger Source Is a Channel from CH1 to CH8 Set the trigger source (CH1 to CH8). Set the trigger coupling, HF rejection, and noise rejection. ► section 2.3 Set the level used to detect source states. When the Trigger Source Is LOGIC(L) or LOGIC(A|B) Set the trigger source (LOGIC(L) or LOGIC(A|B)).* Set the source bit (L0 to L7, A0 to A7, B0 to B7).* Set the level used to detect source ...

Setting the Serial Bus (Setup)

Note Using the CH8 terminal and LOGIC (L) Port If you perform an analysis or execute a search when using the LOGIC (L) port for input, you cannot specify CH8 as the source. Press the CH8 key in advance to enable input from the CH8 terminal. Press the Setup soft key to display the following menu. Manual Setup During Automatic Setup Executes auto setup Set the bit rate (4800 bps, 9600 bps, 19200 bps, User Define). Set counter error detection on or off. Configure the detection level and the hysteresis. Set T Sample. Set the bit rate and clock ...

Angle Cursor Measurements (Degree)

This section explains the following settings (which are used when measuring with angle cursors). • Cursor measurement • Cursor type • Source waveform • Measurement items • References • Cursor jumping • Cursor position ► “Angle Cursors (Degree)” in the Features Guide CURSOR Menu Press CURSOR to display the following menu. Set measurement items. Select the measurement items that you want to use. Turns cursor measurement on and off Set the cursor type to Degree. Set the source waveform (All, CH1 to CH8, LOGIC(L),* LOGI ...

13.2 Measuring Histogram Parameters

This section explains the following settings (which are used when measuring histogram parameters). • Measurement mode • Measurement items • Cursor measurement ► “Measurement (Measure Setup)” in the Features Guide ANALYSIS Histogram Menu Press ANALYSIS and then the Histogram soft key to display the following menu. Configure parameter or cursor measurements. Set measurement items. (This menu item only appears when the measurement mode is set to Param.) Set the measurement mode. Set the cursor positions. • Cursor1 • Cursor2 ...

Setting the List Display (List)

Press the List soft key to display the following menu. Set the list size and the display position (Full Screen, Half(Upper), Half(Lower)). Lists the analysis results Analysis number Turns zoom linking on or off Set the analysis number. Data before the trigger position (on the left side of the waveform display) is assigned analysis numbers in descending order (-1, -2, and so on). Data after the trigger position (on the right side of the waveform display) is assigned analysis numbers in ascending order (0, 1, 2, and so on). 12.2 Analyzing and ...

2.13 Triggering on SENT Signals (Option)

This section explains the following settings (which are used when triggering on SENT signals). • Trigger source Bit rate and the level used to detect the source state • Format • Trigger type Trigger condition ►�“SENT�Trigger�[ENHANCED,�option]”�in�the�Features�Guide Auto Setup The DLM4000 can automatically set the trigger source level and bit rate from the received SENT signal and trigger on them. For details, see section 12.6. ENHANCED_SENT Menu Press ENHANCED and then the Type soft key. From the setup m ...

YOKOGAWA DLM4000 Series user guide recommended for: 701928, DL2700 Series, 30032A, SL1000, AQ1200A.

⚠️ Download Safety

The Test Equipment Operation & user’s manual (302 pages) is completely safe to download (last scan date: 20/12/2025).

Related PDF Instructions for YOKOGAWA DLM4000 Series:

Test Equipment Equipment: Frequently Requested

Have some Questions about YOKOGAWA DLM4000 Series Device?

Get valuable and actionable advices from other YOKOGAWA DLM4000 Series device users. Describe your problem or question, regarding the using of DLM4000 Series, in as much detail as possible, and other users will be able to answer you.