Resolution RE508X Installation Manual

Text of Resolution RE508X Installation Manual

Resolution RE508X Installation Guide: RE508X Hardwire to Wireless Translator™

• Selectable wireless panel compatibility • Rechargeable backup battery • Accepts any existing hardwire zone type • Automatic zone polarity and end of line detection • Battery backed 12VDC output for powered zones • Cover tamper • Certified to UL1023 and ULC1023 PANEL ENROLLMENT (For full zone enrollment instructions, refer to Advanced Setup, step 3) A Enroll Translator int

MOUNT AND WIRE

A Select a mounting position and location. • Mount the translator at least 5 feet from the Control Panel’s receiver. • Do NOT mount the translator in a metal can or on a metal surface. • Verify adequate RF signal strength at the panel before permanently mounting. B Wire the zones. • End of line resistors are not required. • Normally closed zones may have end of line resistors up to 15k ohms.

PANEL ENROLLMENT (continued)

DSC ® Translator enrollment: Enter Wireless Enrollment mode. Trip the translator cover tamper to enroll the translator. Zone Type: 03 • For the first 24 hours after power-up, all translator tamper trips will send a temporary “open” for enrollment purposes. Zone enrollment: Enter Wireless Enrollment Mode. Trip each zone to initiate enrollment. Confirm ESN, Enter Zone #, and Zone Type. Setup the zone for the desired behav

“GE”, “INTERLOGIX”, “HONEYWELL”, “DSC”, “2GIG”, AND “QOLSYS” ARE TRADEMARKS OWNED BY

GENERAL ELECTRIC COMPANY, UNITED TECHNOLOGIES ELECTRONIC CONTROLS INC., HONEYWELL INTERNATIONAL INC., TYCO SAFETY PRODUCTS CANADA LTD, NORTEK SECURITY & CONTROL LLC, AND TYCO SAFETY PRODUCTS CANADA LTD, RESPECTIVELY. RESOLUTION PRODUCTS, INC. PRODUCTS WILL FUNCTION WITH ONE OF EITHER INTERLOGIX (FOR- MERLY GE), HONEYWELL, DSC, 2GIG OR QOLSYS SYSTEMS