CONTENTS DOMESTIC HOT WATER CONSUMPTION ............................................................................................................... 4 SOLAR WATER HEATER OPERATION - WATER HEATING ..................................................................................... 4 SOLAR WATER HEATERS ......................................................................................................................................... 5 LABELING .............................................................. ...
NOBEL, Xilinakis D. & Co Industry is active in the Solar Energy Field since 1975, always with high-tech equipment, ultra-modern facilities and certified products of high quality. Our experience and know-how support our co operations, before and after sales, both in Greece and abroad. In the present manual you will find all necessary instructions with regard to the installation, operation and maintenance of NOBEL Solar Water Heaters. Nowadays, the necessity for production and saving of energy without at the same time poll ...
SOLAR WATER HEATERS RELIABILITY - HARMONY - AESTHETICS NOBEL Solar Systems constitute an ecological proposal and an effective energy solution, combining high output, autonomy, aesthetics, facility in the installation and money saving. They are made of excellent materials according to international specifications and have all the certifications and tests that confirm their quality. They are highly aesthetic systems, which can be simply and quickly installed to blend with the traditional or modern architecture of a ...
SOLAR WATER HEATERS FITTINGS & ACCESSORIES 1 COLLECTOR 2 COLLECTORS Quantity Description Quantity Description 2 PCS ELBOW Ø22 COPPER X DN16 INOX 2 TEM. T-PIECE Ø22 COPPER X DN16 INOX X Ø22 COPPER 1 PC FEMALE CONNECTOR 3/4 X DN16 2 PCS FEMALE CONNECTOR 3/4 X DN16 1 PC ELBOW FEMALE CONNECTOR 3/4 X DN16 1 PC ONE WAY SAFETY VALVE 10 bar 2 PCS END CAP Ø22 1 PC CLOSED LOOP SAFETY VALVE 3.5 bar 1 PC ONE WAY SAFETY VALVE 10 bar 2 PCS INOX TUBE DN16 1 PC CLOSED LOOP SAFETY VALVE 3.5 bar 1 PC INSULATION ARMAFLEX Ø22 2 PCS I ...
WATER STORAGE TANK SPECIFICATIONS STEEL - ENAMEL 1. Water tank: 2.5mm thickness cold rolled steel with a double internal layer of enamel, fired at 860°C according to DIN 4753. The enameling is done in our own high tech industrial facilities. The water storage tanks are checked individually upon exit from the enameling unit, assuring the top quality of the enamel. 2. Surrounding heat exchanger (Jacket) with internal expansion tank of cold rolled steel, for the operation of the closed loop, which is compulsory at ...
COLLECTOR APOLLON AL SPECIFICATIONS 1. External one piece aluminium trough of high aesthetics, shaped by deep drawing method in 400 tn capacity press, made of naval aluminium alloy, rich in magnesium. Robust construction for perfect tightness. 2. High density, eco-friendly thermal insulation achieved with a 60mm thick layer of prepressed rockwool with a covering of black glass fabric for the minimization of thermal losses. Rockwool insulation thermal conductivity: λ=0.035 W/m grd (DIN 56612, measured at 0°C) 3. Water f ...
YEARLY ENERGY OUTPUT (kWh/m2) ATHENS - GREECE 614 DAVOS - SWITZERLAND 795 WÜRZBURG - GERMANY 571 STOCKHOLM - SWEDEN 535 Normal absorber design with louvers. Air turbulence increases heat loss Complete area technology The uniform area prevents heat loss FLAT SURFACE INCLINED SURFACE One type of supporting base system, electrostatically painted, made of 2.5mm thick galvanised steel, with stainless steel screws and nuts for installation on flat or inclined surfaces SUPPORT BASE ...
WATER STORAGE TANK 120lt DIMENSIONS (mm) 560x1095 WEIGHT EMPTY (kg) 49 JACKET CAPACITY (lt) 8.6 JACKET SURFACE (m2) 0.6 MAX. TEST PRESSURE (bar) 15 MAX. OPERATING PRESSURE (bar) 10 COLLECTOR APOLLON AL 2000 TOTAL AREA (m2) 2.03 NUMBER OF MANIFOLDS 10 HEAT TRANSFER MEDIUM PROPYLENE GLYCOL SOLUTION CAPACITY (lt) 1.75 ABSORBER SURFACE (m2) 1.8 TOTAL DIMENSIONS (mm) 2010x1010x110 COLLECTOR TOTAL WEIGHT (without liquid) (kg) 38 ABSORBER SUN - SELECTIVE ALUMINIUM ABSORBENCY / RADIATION COEFFICIENT 95% +/-2% / 5% +/-2% TOTAL S ...
WATER STORAGE TANK 160lt DIMENSIONS (mm) 560x1325 WEIGHT EMPTY (kg) 60 JACKET CAPACITY (lt) 12.9 JACKET SURFACE (m2) 0.9 MAX. TEST PRESSURE (bar) 15 MAX. OPERATING PRESSURE (bar) 10 COLLECTOR APOLLON AL 2000 TOTAL AREA (m2) 2.03 NUMBER OF MANIFOLDS 10 HEAT TRANSFER MEDIUM PROPYLENE GLYCOL SOLUTION CAPACITY (lt) 1.75 ABSORBER SURFACE (m2) 1.8 TOTAL DIMENSIONS (mm) 2010x1010x110 COLLECTOR TOTAL WEIGHT (without liquid) (kg) 38 ABSORBER SUN - SELECTIVE ALUMINIUM ABSORBENCY / RADIATION COEFFICIENT 95% +/-2% / 5% +/-2 ...
WATER STORAGE TANK 160lt DIMENSIONS (mm) 560x1325 WEIGHT EMPTY (kg) 60 JACKET CAPACITY (lt) 12.9 JACKET SURFACE (m2) 0.9 MAX. TEST PRESSURE (bar) 15 MAX. OPERATING PRESSURE (bar) 10 COLLECTOR APOLLON AL 2600 TOTAL AREA (m2) 2.53 NUMBER OF MANIFOLDS 13 HEAT TRANSFER MEDIUM PROPYLENE GLYCOL SOLUTION CAPACITY (lt) 2.12 ABSORBER SURFACE (m2) 2.3 TOTAL DIMENSIONS (mm) 2010x1260x110 COLLECTOR TOTAL WEIGHT (without liquid) (kg) 45.4 ABSORBER SUN - SELECTIVE ALUMINIUM ABSORBENCY / RADIATION COEFFICIENT 95% +/-2% / 5% +/-2% TOTA ...
WATER STORAGE TANK 160lt DIMENSIONS (mm) 560x1325 WEIGHT EMPTY (kg) 60 JACKET CAPACITY (lt) 12.9 JACKET SURFACE (m2) 0.9 MAX. TEST PRESSURE (bar) 15 MAX. OPERATING PRESSURE (bar) 10 COLLECTOR APOLLON AL 1500 TOTAL AREA (m2) 1.52 NUMBER OF MANIFOLDS 10 HEAT TRANSFER MEDIUM PROPYLENE GLYCOL SOLUTION CAPACITY (lt) 1.45 ABSORBER SURFACE (m2) 1.3 TOTAL DIMENSIONS (mm) 1510x1010x110 COLLECTOR TOTAL WEIGHT (without liquid) (kg) 28 ABSORBER SUN - SELECTIVE ALUMINIUM ABSORBENCY / RADIATION COEFFICIENT 95% +/-2% / 5% +/-2 ...
WATER STORAGE TANK 200lt DIMENSIONS (mm) 560x1475 WEIGHT EMPTY (kg) 72 JACKET CAPACITY (lt) 18.3 JACKET SURFACE (m2) 1.3 MAX. TEST PRESSURE (bar) 15 MAX. OPERATING PRESSURE (bar) 10 COLLECTOR APOLLON AL 2600 TOTAL AREA (m2) 2.53 NUMBER OF MANIFOLDS 13 HEAT TRANSFER MEDIUM PROPYLENE GLYCOL SOLUTION CAPACITY (lt) 2.12 ABSORBER SURFACE (m2) 2.3 TOTAL DIMENSIONS (mm) 2010x1260x110 COLLECTOR TOTAL WEIGHT (without liquid) (kg) 45.4 ABSORBER SUN - SELECTIVE ALUMINIUM ABSORBENCY / RADIATION COEFFICIENT 95% +/-2% / 5% +/-2% TOTA ...
WATER STORAGE TANK 200lt DIMENSIONS (mm) 560x1475 WEIGHT EMPTY (kg) 72 JACKET CAPACITY (lt) 18.3 JACKET SURFACE (m2) 1.3 MAX. TEST PRESSURE (bar) 15 MAX. OPERATING PRESSURE (bar) 10 COLLECTOR APOLLON AL 1500 TOTAL AREA (m2) 1.52 NUMBER OF MANIFOLDS 10 HEAT TRANSFER MEDIUM PROPYLENE GLYCOL SOLUTION CAPACITY (lt) 1.45 ABSORBER SURFACE (m2) 1.3 TOTAL DIMENSIONS (mm) 1510x1010x110 COLLECTOR TOTAL WEIGHT (without liquid) (kg) 28 ABSORBER SUN - SELECTIVE ALUMINIUM ABSORBENCY / RADIATION COEFFICIENT 95% +/-2% / 5% +/-2 ...
WATER STORAGE TANK 200lt DIMENSIONS (mm) 560x1475 WEIGHT EMPTY (kg) 72 JACKET CAPACITY (lt) 18.3 JACKET SURFACE (m2) 1.3 MAX. TEST PRESSURE (bar) 15 MAX. OPERATING PRESSURE (bar) 10 COLLECTOR APOLLON AL 2000 TOTAL AREA (m2) 2.03 NUMBER OF MANIFOLDS 10 HEAT TRANSFER MEDIUM PROPYLENE GLYCOL SOLUTION CAPACITY (lt) 1.75 ABSORBER SURFACE (m2) 1.8 TOTAL DIMENSIONS (mm) 2010x1010x110 COLLECTOR TOTAL WEIGHT (without liquid) (kg) 38 ABSORBER SUN - SELECTIVE ALUMINIUM ABSORBENCY / RADIATION COEFFICIENT 95% +/-2% / 5% +/-2% TOTAL ...
WATER STORAGE TANK 320lt DIMENSIONS (mm) 560x2095 WEIGHT EMPTY (kg) 104 JACKET CAPACITY (lt) 25.8 JACKET SURFACE (m2) 1.8 MAX. TEST PRESSURE (bar) 15 MAX. OPERATING PRESSURE (bar) 10 COLLECTOR APOLLON AL 2000 TOTAL AREA (m2) 2.03 NUMBER OF MANIFOLDS 10 HEAT TRANSFER MEDIUM PROPYLENE GLYCOL SOLUTION CAPACITY (lt) 1.75 ABSORBER SURFACE (m2) 1.8 TOTAL DIMENSIONS (mm) 2010x1010x110 COLLECTOR TOTAL WEIGHT (without liquid) (kg) 38 ABSORBER SUN - SELECTIVE ALUMINIUM ABSORBENCY / RADIATION COEFFICIENT 95% +/-2% / 5% +/- ...
GENERAL INSTALLATION RULES ATTENTION: Installation must be in compliance with local & national rules concerning water and electrical installations (plumbing, electricity, hygiene, urban and others). The solar system’s packaging must be removed at the site of installation in order to protect the device from shocks during its transportation, making sure that the collectors are not supported on their pipe joints. Until installation is completed, the collector’s glass must remain covered until the water storage tank is ...
Piping: the routing of the piping and cabling must be agreed upon between the installer and the client, so as to ensure the proper installation of the solar system in compliance with local rules concerning water and electrical installations. Make sure that the tubes connecting the storage tank with the collector and the piping to/from the water heater are insulated in such a way that they can withstand temperatures covering the range of: -30°C to 120°C. Anti-UV protection must be used for the insulation. Antif ...
Space requirements for free standing installation FLAT ROOF The system should be installed at least 1.5m away from the edges of the roof so as for: 1. The systems to be accessible for maintenance reasons. 2. The systems and the fixing system not to be exposed to strong winds which are developed at the ends and edges of the roof. 3. The snow to be removed. GENERAL PREVENTION MEASURES y Please respect the instructions related to accidents prevention and the safety rules during the installation of the solar thermal system ...
Water Heater PDF Instructions
Comprehensive setup guide for the Heatmaster TC series Water Heater. It offers guidance for setup and safety features, error handling, cleaning instructions.
4 210 803 / 00 - 09/11 Calorifier CombiVal CR (200-2000) CombiVal CSR (300-2000) MultiVal CRR (300-2000) MultiVal CSRR (540-2000) EN Subject to modifi cations Hoval products must be installed and commis- sioned only by appropriately qualifi ed experts. These General instruction manual for the Hoval CombiVal CR (300) Boiler. The document provides guidance on safety and menu navigation, product safety, safety protocols.
User’s Manual Doc. 1294A H2359301A User’s Manual for WARNING If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. Do not store or use gasoline or other flammabl Setup instructions for the Bradford White Brute MagnaTech BMGH1600 Boiler. The document covers assembly reference, replacement parts, troubleshooting guides, usage recommendations.
Owners Manual FOR POTABLE WATER HEATING ONLY NOT SUITABLE FOR SPACEHEATING NOT FOR USE IIX[, MOBILE HOMES Hodel No. 153.334290 40 Gal. Short 153.334390 30 Gal. IS3.334490 40 Gal. 153.334S90 S0 Gal. Caution: Read and Follow All Safety Rules and Operating Instru User instruction booklet for the Kenmore 153.334590 Water Heater. It explains system setup, detailing setup, operational procedures, system configuration.