Extech Instruments RH350 Operation & User’s Manual

Brand: Extech Instruments
Category: Measuring Instruments
Model: RH350 (Operation & User’s Manual)
File Type: PDF
File Size: —
Pages: 6
Text of Extech Instruments RH350 Operation & User’s Manual

Extech Instruments RH350 RH350/355 V2.1 8/08

2 Introduction Congratulations on your purchase of the Extech RH350 SuperHeat Psychrometer. This device measures Differential Temperature (T1-T2, Air-T1, T1-DP), Humidity, Air Temperature, Dew Point and Wet Bulb. Advanced features include built-in memory and recall of up to 99 data points, Min/MAX/Average readings from the captured data, Data Hold, selectable Auto Power Off, and an RS-232 interface for capturing readings to a PC u
RH350/355 V2.1 8/08 3 Operation Open the Protective Sensor Cap Twist the protective sensor cap, located at the top of the meter, counter-clockwise a quarter of a turn to expose the sensors. Turn Power ON or OFF Press the [ON/OFF] button to turn power on or off. The meter will perform a short self-test when turned on. Taking measurements 1. Hold the probe in the area to be tested. 2. Allow adequate time for readings to stabilize. 3. The Relative Humid
RH350/355 V2.1 8/08 4 Backlight Display Press the [M in/AVRST] and [MEM] buttons together to turn on the backlight. It will remain on for ten seconds. Automatic Power OFF With the meter off, press and hold down the [ON/OFFSET] + [RECHOLD] buttons for more than 1 second to enter auto power off settings. Press the [MEM] button to select non-sleep (n) or 2, 5, 10, 20, 40 and 60 minutes autosleep. Press [T2▲WB] to confirm the selection. Manual Datalog
RH350/355 V2.1 8/08 5 CALIBRATION The following verification and calibration procedures require the 33% and 75% RH reference bottles which are supplied with the Model RH355 kit. Accuracy Verification Checking the 33% or 75% RH Calibration 1. Insert meter’s sensor into the 33% or 75% salt reference bottle 2. Check the reading after a minimum of 10 minutes 3. Verify that the reading is within the accuracy specification Relative Humidity Calibration (
RH350/355 V2.1 8/08 6 � Support line (781) 890-7440 Technical support: Extension 200; E-mail: [email protected] Repair & Returns: Extension 210; E-mail: [email protected] Product specifications subject to change without notice For the latest version of this User’s Guide, Software updates, and other up-to-the-minute product information, visit our website: www.extech.com Specifications Function Range and Resolution Accuracy Humidity 0.0 to 100.0%