EA80 V2.1H 11/06
3
Preparation for Use
Power Supply
The meter is powered by six AAA-size alkaline batteries or an AC adapter.
Installing the Batteries
Insert six AAA-size batteries as indicated by the diagram located on the inside of the
battery compartment.
When the battery voltage drop below the operating voltage, the “ +
” indicator will
be displayed indicating that the batteries need to be changed.
AC Adapter
The AC adapter allows you to power t
EA80 V2.1H 11/06 4
Humidity Measurement
1.
Press the “
” button to power on the meter.
2.
The display will show the humidity reading value (% RH) directly on the third
display.
3.
Hold the probe in the air in the area to be tested. Do NOT immerse in liquid.
4.
Allow adequate time for readings to stabilize.
5.
Read the measurements on the LCD.
Temperature Measurement
1.
Press the “
” button to power on the meter.
2.
Press the °C/°F button momen
EA80 V2.1H 11/06 5
MAX
CO2
ppm
d-h
m:s
8
MIN
CO2
ppm
d-h
m:s
CO2
ppm
d-h
m:s
CO2 Maximum and Minimum Recording Measurement
1.
Press “MX/MN” button to enter the maximum / minimum
recording mode, the “MAX” icon appears on the display.
The maximum CO2 reading will be displayed and will be
updated only when a higher reading occurs.
2.
Press “TIME” button to enter time display mode.
Displays 2 and 3 will indicate the time the maximum
reading occur
EA80 V2.1H 11/06 6
SET
ALM
CO2
ppm
ppm
CO2
ppm
CO2
CO2 Alarm Operation
Setting the Alarm Limit Values
1.
Press “ALARM” button to turn on the alarm function, the “ALM” icon, and current
value are displayed.
2.
Press “SET” button to enter High/Low limit value
setting mode, the “SET” icon is displayed and
hundred and thousand digits of the high limit value
will flash.
3.
Press “�” or “�” button to set desired value.
4.
Press “�
EA80 V2.1H 11/06 7
Manual Dataogging
Storing readings
Press " MEM " button. LCD will display " M " and the
memory address number. Total
memory size is 99 readings.
Viewing readings.
Press " READ " button to enter READ mode. The LCD
will display " R " and the memory address number.
Press " �" or " �" button to scroll through stored readings
Press " ↵ " enter button to exit this mode.
Deleting stored data
Press “ SET ” button three times, the L
EA80 V2.1H 11/06 8
Calibration
CO2 Calibration
1.
Press “
” button to turn the meter on.
2.
Place the probe in a known CO2 reference for 10 minutes.
3.
Press the “SET” button 5 times until “C-01” is displayed in the second display.
4.
Press “►” or “◄” button to select digits to adjust (flashing).
5.
Press “▼” or “▲”button to adjust the display to the reference value.
6.
Press “↵” to store the value and exit the c
EA80 V2.1H 11/06 9
Specifications
Display :
LCD triple display.
Display Rate :
One time per second.
Low Battery Indication :
The “ +
” is displayed when the battery voltage drops below
the operating voltage.
Power Supply :
Six (6) AAA-size alkaline batteries.
or Regulated AC adapter.
Battery Life :
Approx. 8 hours by using alkaline batteries (without
backlight or Alarm function). If datalogging over a long
period of time, use an AC adapter.
Manual D
EA80 V2.1H 11/06 10
Maintenance
Cleaning
Periodically wipe the case with a dry cloth or a damp cloth with mild detergent.
Do not use abrasives or solvents to clean this instrument.
Battery Replacement
When the “ ” symbol appears on the LCD, the six 1.5V ‘AAA’ must be replaced.
1. Turn the meter off.
2. Remove the meter’s battery cover
3. Replace the batteries observing polarity
4. Affix the battery cover and secure the rear screws.
RS-