General MMD950 Operation & User’s Manual
Text of General MMD950 Operation & User’s Manual
PIN/PINLESS DEEP SENSING
MOISTURE METER
WITH SPHERICAL SENSOR
AND REMOTE PROBE
USER’S MANUAL
MMD950
99 Washington Street
Melrose, MA 02176
Phone 781-665-1400
Toll Free 1-800-517-8431
Visit us at www.TestEquipmentDepot.com
TABLE OF CONTENTS
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 – 4
Key Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
What’s in the Case . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Setup Instructions . . . . . . . . . . . . . . .
Thank you for purchasing General Tools & Instruments’ MMD950 Pin/Pinless
Deep Sensing Moisture Meter with Spherical Sensor and Remote Probe. Please
read this user’s manual carefully and thoroughly before using the meter.
The MMD950 is designed for use in woodworking, water damage restoration,
building construction and home renovation. Examples include:
• Checking for moisture on or below the surface of carpets and sub-
flooring
• Mea
2. Locating the source of a water leak above a ceiling, by comparing the
REL readings at various points on it. If the ceiling is level, the point with
the highest REL reading is below the source of the leak.
The biggest advantage of the spherical sensor is its ability to sense moisture up
to 4 in. below or behind the surface of a material. The remote probe’s pins can
also sense moisture just below the surface of some materials. However, for
hard material
The figure shows all of the controls, indicators and physical features on the
front, bottom, top, back and right side of the MMD950. Familiarize yourself with
their positions and functions before moving on to the Setup Instructions.
A. Spherical sensor
B. Measurement mode indicator
(REL shown)
C.
Indicates beeper is
enabled
D.
Indicates battery is
weak
E. Jumbo LCD display
F. Five-function Mode button
G. Four-function
button
H. Battery/s
To power on the meter, press the
button and hold it for at least three
seconds. (To power off the meter, follow the same instruction.)
By factory default:
• The beeper is enabled, and beeps faster the higher the readout above
17%WME in pin measurement mode (17 in REL mode).
• The auto power off function is enabled, and activated by 3 minutes of
front-panel inactivity.
• The backlight is on.
• Manual calibration checking (see
press the spherical sensor against a material known to be completely dry. This
should produce a reading of 0 on both the LCD and LED bar graphs. Then press
the spherical sensor against one or more points on the target surface and
compare the readings.
Some measurement tips:
1. The spherical sensor’s accuracy is not affected by its angle relative to
the target surface. Press the sphere against the material at the angle
that makes the LCD easiest to read.