Datasensor SCS1 Series Instruction Manual
Text of the manual
Smart Camera Sensor
INSTRUCTION MANUAL
Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - e.mail: [email protected]
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Phone: 800.894.0412 - Fax: 888.72
DDEECCLLAARRAATTIIOONN OOFF CCOONNFFOORRMMIITTYY
We
DATASENSOR S.p.A.
Via Lavino, 265
40050 Monte San Pietro
Bologna - Italy
declare under our sole responsibility that the product(s)
SCS1-XX-XXXX-XXX, SMART CAMERA SENSOR AND ALL ITS MODELS
To which this declaration relates in conformity with the following
standard(s) or other normative document(s)
CEI EN 5
1. GENERAL INFORMATION
1.1. General description of SCS1 Smart Camera Sensor
SCS1 is an user-friendly vision sensor equipped with advanced inspection capability that assures very
precise quality controls on industrial manufacturing and automatic materials handling lines.
Quality control is based on vision techniques that consi
1.3. Typical applications
Typical SCS1 applications consist in quality and integrity controls of assembled products on an
industrial manufacturing line.
Some examples:
Label presence on phials / bottles
Presence of mechanical parts
Marking control
Contour control (contour match)
Component control on PCBs
Similarity check with
The system is composed of:
-
compact sensor housing with reduced dimensions and weight;
-
standard industrial connectors (M8, M12);
-
16 mm C-mount lens with 5 mm adapter ring to make it compatible with the sensor’s CS-
mount;
-
RJ45 connector with Ethernet PC connection;
-
LED function indicators and 4-digi
2. ELECTRICAL CONNECTION
M12 connector
2
8
1
5
3
4
7
6
+ 24 Vdc
GND
OUTPUT 2
EXTERNAL TRIGGER
RS232 TX / RS485 - /
INPUT1
OUTPUT 1
CONFIGURABLE
INPUT
RS232 RX / RS485 + /
INPUT2
1 = white
= RS232 TX / RS485 -/ Input1
2 = brown
= 24 Vdc power supply
3 = green
= Configurable input
4 = yellow
= Output 1
5 = grey
= Output 2
3.1. Hardware connection
Check the following necessary components:
- SCS1 sensor;
- 16mm C-mount lens and adapter compatible with the sensor’s CS-mount. Alternatively, any
optics with CS mounting or C mounting with adapter;
- cable with M12 8-pole connector;
- 24 Vdc power supply.
And if necessary:
- cable w
6) Optional: connect external illuminator to the sensor using the M8 4-pole connector.
-
Optional: connect the sensor to the PC using the Ethernet 10/100 Mbps cable.
Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - e.mail: [email protected]
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.c
3.2. Installation and activation of SCS1 graphic interface
3.2.1.
Minimum system requirements:
-
Celeron® 700 Mhz processor
-
128 MB RAM
-
super VGA monitor (800x600 pixel)
-
Ethernet 10/100 Mbps card
-
20 MB of available space on hard disc
-
CD-ROM drive
Recommended system:
-
Pentium® 4 2 Ghz processor
-
256 MB RAM
-
monit
3.3. Communicating with the sensor
The PC and sensor communicate using the Ethernet network and require compatible IP addresses.
Note: an IP address is equivalent to a telephone number. The PC connects itself to the sensor only
when the sensor’s IP address is known, just like the phone number of the person to contact.
Diffe