DanVex DEH-600wp Instruction Manual

Specifications

Brand: DanVex
Category: Other
Model: DEH-600wp (Instruction Manual)
File Type: PDF
File Size: —
Pages: 18

Read Online

Read the DanVex DEH-600wp Instruction Manual online using the built-in PDF viewer.

Text of the manual

Please read this instruction manual carefully and save it before using the dehumidifier. If you

have any questions about using the dehumidifier, please contact Your dealer.

PRECAUTIONARY MEASURES .....................................................................................................

DESCRIPTION OF THE DEHUMIDIFIER ....................................................................................... WIRING DIAGRAMS ....................................................................................................................... INSTALLATION NOTE .................................................................................................................... START-UP AND OPERATION (DESCRIPTION OF THE CONTROL PANEL) ................................ REMOTE CONTROL AND ERROR CODES ................................................................................... DEHUMIDIFIER MAINTENANCE .................................................................................................... TECHNICAL SPECIFICATIONS ...................................................................................................... WARRANTY TERMS AND WARRANTY CARD .............................................................................. CONTENTS 3 4 6 7 8 9 11 12 13 14

All the dehumidifiers described in this manual are designed to maintain the relative

humidity of indoor air in the range from 40% to 99%, at air temperature from +10°C to +32°C. 3

Read this manual carefully for safety before

you start operating the dehumidifier. Below are the symbols used in this manual.  If dirt sticks to the plug of the power cord or plug and socket connection is loose, it may cause fire or electric shock. PRECAUTIONARY MEASURES CAUTION Remove any dirt from the plug of the power cord. There should be no breaks in the cord or its artificial extensions. Do not scratch or bend the power cord.  Do not place heavy objects on the power cord, heat it, or expose to other factors. The cable may be damaged, which can lead to fire or electric shock. Consult Your dealer on installation of the device. Do not insert fingers or any objects into the air intake/ outlet. Do not attempt self-repair or re-installation of the device.  If this is done incorrectly, it may cause fire, electric shock, water leakage, etc.  Contact Your dealer. Strictly forbidden Be sure to follow the instructions Provide grounding Unplug the power cord from network Never store anything on the device Electric shock hazard Never insert fingers or any items Do not disconnect / do not connect power supply during operation If during operation there is something unusual (burning smell, etc.), turn off the device and disconnect it from the network Use grounding.  In case of incorrect operation of the device, contact Your dealer.  Avoid contact of the grounding wire with gas and water pipes, lightning rod or telephone cable. If the grounding is made incorrectly, it can lead to defeat electric shock hazard.

This may cause fire or deformation.

PRECAUTIONARY MEASURES CAUTION Do not use insect repellent or solvents. Before cleaning the device switch it off and disconnect the power cable from the mains.  It can cause a short circuit that may result in electric shock or fire. Do not clean the device with water. ● This can lead to electric shock.  As the fan rotates at high speed, cleaning of operating device can cause injury. If the device is installed in a damp location, ensure its isolation from moisture.  If you do not provide isolation of the device from moisture, it may cause electric shock.  If You do not, the device may accumulate dirt and cause a fire. If You are not going to use the device during a long period, unplug it from the mains.  Do not install the device in a place where there is flammable gas. Do not install the device where in unsafe operation conditions. Do not press the switches with wet hands.  This may cause electric shock. Unassisted installation of the device is forbidden.  If this is performed incorrectly, it may cause fire, electric shock, water leakage, etc.  Please contact Your dealer or technician. Do not pull on the power cord.

AIR DEHUMIDIFIERS: DEH-600wp and DEH-1000wp

DEHUMIDIFIER DESCRIPTION Power cord Power cord Drain hose Moist air input Mounting bracket Dry air output Control panel

SINGLEPHASE (1PH/50 Hz)

WIRING DIAGRAM Датчик влажности Датчик температуры воздуха Датчик системы разморозки Вывод на дисплей PCB Трансформатор Главный контроллер PCB Мотор вентилятора Компрессор Источник питания Main controller PCB Humidity detector Air temperature sensor System defrost sensor PCB display representation Compressor Fan motor Power source Transformer Protection from low pressure Protection from high pressure

9Mounting of the dehumidifier on the wall:

Step 1: Select the correct position for mounting on the wall, depending on the size of the holes set and the holes positions of the wall mount bracket. The place of installation should guarantee the vertical position of the dehumidifier. Mark places for drilling. Step 2: Use hammer drills to drill holes with depth of 8 ± 0.5 cm Then use the anchor bolts and install them into the holes with a hammer. Step 3: Install the wall bracket with anchor bolts in the correct position. Please, provide secure fixing of the bracket using nuts and washers. Don't forget to hold the bracket in the correct position during installation. Step 4: Install the dryer on the wall bracket. Step 5: Connect the drain hose to the dehumidifier. Turn on the dehumidifier for trial use. Check the device for presence of abnormal vibration and noise. Step 6: Installation is finished and the dehumidifier is ready for use. Installation diagram. In case of indoor installation of the device, provide availability of free space for its maintenance. The premises, where the device is installed, must be ventilated. Before installation of the dehumidifier: Before shipment from the factory all the dehumidifiers are subject to tests. Unpack the box and check for damage on the surface of the device, as well as for completeness of components in accordance with the list specified in the instructions. If You find any damage, do not attempt to install the humidifier and immediately contact the supplier. IF DURING TRANSPORT THE DRYER WAS LYING ON THE SIDE, IT NEEDS TO BE LEFT UPRIGHT FOR AT LEAST 24 HOURS BEFORE THE START OF ITS OPERATION!!! (failure to perform this may cause damage to the dryer and void your warranty) CAUTION!!!

START-UP AND OPERATION

Description The control panel is designed to exercise the control functions over the dehumidifier operation, change of parameters of operation and maintenance of the specified values for these parameters. The panel consists of control buttons and LCD screen. Buttons are used for switching on/off and changing of parameters and modes of operation of the dehumidifier. At the top of the panel screen the current time (if configured), and operation mode on the basis of the built-in humidity sensor, constant operation, ventilation mode, current values of humidity and temperature, set/preset humidity value, the status of the timers and their settings are displayed. Designation of control buttons: (ON/OFF) - on / off of the dehumidifier, (UP) - increase of the parameter (humidity, time), (DOWN) - decrease of the parameter (humidity, time), (MODE) - Change (selection) of the operation mode (built-in humidity sensor / external humidity sensor / constant dehumidification / ventilation mode), (TIME) - setting the timers and time (TIMERSET) - selection of timer operation mode (off /once /daily)! Names an values of parameter: INTERNAL - activated internal / built-in humidity sensor, EXTERNAL - activated external humidity sensor (have to be connected, in the absence of contact, error E7 is displayed), CURRENT HUMIDITY - current/valid humidity, CURRENT TEMPERATURE - current/actual air temperature, TIMER ON – time of switching on the dryer when the timer is operating; TIMER OFF – time of switching off the dryer when the timer is operating; OFF - timers are disabled, TIME - single cycle of the timer operation; EVERY DAY - daily mode of the timer operation. Control panel of the dehumidifier

START-UP AND OPERATION

CAUTION!!! Please carefully review the control functions and make all necessary adjustments before using the dehumidifier. Operation procedure and parameters setting. For starting of dehumidifier you need to make some not difficult things: 1. By the means of one-time push of the ON/OFF button, the dehumidifier is switched on, the panel issues a short beep and the screen lights are activated. 2. By the means of pressing UP and DOWN buttons set the required humidity value (displayed in large digits) which is expected to be maintained in the premises (by default 60%). 3. The MODE button will enable the INTERNAL mode for operation on the built-in humidity sensor or EXTERNAL mode for operation on the external humidity sensor (not supported). 4. If the current humidity is higher than the preset by at least 2-3%, the dehumidifier starts running (the fan, then the compressor/compressors are enabled). The dehumidifier will be disabled at excess of the fixed value by 2-3%. The clock and timers setting. To set the time, press the TIME button, at the top of the screen the two characters will flash, responsible for the clock "- - " - - . Then, by the means of the UP and DOWN buttons set the current time in hours. Then press the button TIME again, the characters responsible for the minutes - - " - - " will flash, by the means of pressing UP and DOWN buttons set the current time in minutes. To configure the on / off timers, press the button TIME three times, the symbols of hours of the timer will be flashing, by the means of pressing the UP and DOWN buttons, set the time in hours, press the TIME button again, the symbols of the timer minutes will be flashing, by the means of pressing the UP and DOWN buttons, set the time in minutes. Press the TIME button again, the symbols of hours of the off-timer will be flashing, by the means of UP and DOWN buttons select the off time in hours, press the TIME button again, the symbols of the minutes of the off-timer will be flashing, by the means of the UP and DOWN buttons select the off time in minutes. Now select the mode of operation of the timer by the TIMERSET button.

REMOTE CONTROL AND ERROR CODES

REMOTE CONTROL ERROR CODES The dehumidifier is equipped with a self-diagnostic system. In case of detection of problems, the error code will be represented at the LCD display. E2 - heat exchanger temperature sensor error; E3 - air temperature sensor error; E7 - humidity sensor error . The scope of supply includes the infrared remote control. The remote buttons duplicate some of the functions of the control panel of the dehumidifier. To start using the remote you need to insert the battery R232 (supplied separately). Button up Button down Оn/off button

When You are not going to use the

dehumidifier for a long time. When you are going to operate the dehumidifier again. Start the process of air drying for 3- 4 hours, setting the humidity levels at the level of 80% to dry the dehumidifier from inside. Switch off the dehumidifier, then remove plug from outlet. Make sure the air intake and outlet are not blocked. Make sure the ground wire is connected properly CAUTION Switch off the dehumidifier or remove the plug from the socket if you are not going to use it for a long time. CAUTION Use grounding. Avoid contact of the grounding wire with gas and water pipes, lightning rod or telephone cable. If grounding was performed incorrectly, this may result in electric shock. Remove the batteries from the remote control.

Productivity (l/day) at 30°С/80%

60 100 Power (W) 920 1260 Current strength (А) 04.мар 6 Air capacity (mЗ/hour) 450 500 Refrigerant volume, trademark (year, R407C) 500 550 Noise level (dB) 46 48 Net weight(kg) 50 55 Overall dimensions LxWxH (mm) 915X280X670 915X280X670 230V/1~/50Hz R www.danvex.fi 13 TECHNICAL SPECIFICATIONS NOTE: 1. The nominal value of the noise level recorded in the laboratory. 2. In case of difference between the characteristics shown in the table above and the characteristics specified directly on the manufacturer label, you need to rely on the characteristics of the manufacturer's label. 3. Test data: air temperature 30°C, humidity 80%. SPECIAL INSTRUCTIONS: 1. For expert installation and repair, contact the special Service department. 2 If a flexible cable is damaged, contact the special Service Department to replace it with the original cable.

WARRANTY CARD AND WARRANTY OBLIGATIONS

ITEM TYPE, MODEL: ____________________________________________________ PURCHASE DATE:__________________ Warranty scope and equipment, to which warranty is applied: The equipment covered by this warranty is listed below: The supplier will provide a replacement part in case of its failure during normal use in non- aggressive dust-free environment and regular maintenance during the warranty period specified below, in accordance with the terms of this warranty. The date of delivery of warranty replacement parts is 30 days. The warranty for the replaced item will be given only for the remaining period of the original warranty period. Equipment subject to guarantees: The warranty is applied to all equipment DanVex and its components. Date of entry into force and guarantee terms: Start date of warranty period is the date of sale. The warranty period for dehumidifiers DanVex of the series "wp" is 24 months. Exceptions - THIS WARRANTY DOES NOT COVER: 1. Equipment, which was not installed in accordance with the manual. 2. Equipment, which is not operated in accordance with the manual, for example, in aggressive environments (oils, salts, chlorine, etc. high temperature), multiple cover damages. 3. Items returned not through the distributor of the Manufacturer. 4. Items returned later than 30 days after failure. 5. Items returned after the date of expiration of the warranty period, including the items, gone out of operation during the warranty period, but returned after its expiration. 6. Damage, malfunction or failure that occurred during or as a result of transportation or movement, improper operation, accidental accidents, fires, floods and other similar situations. 7. Equipment in dirty state. 8. Damage, malfunction or failure occurring as a result of installation, operation or maintenance of the unit, produced not in accordance with the Manufacturer's instructions outlined in the installation manual, in violation of the accepted manufacturing practices and any applicable local, state and national standards. 9. Damage, malfunction or failure occurring as a result of using additional equipment, accessories, or parts that have not received approval and authorization of the Manufacturer. R www.danvex.fi 14

Compliance with the declared characteristics:

The manufacturer guarantees the compliance of the technical characteristics of the equipment stated in the instruction manual, only subject to clean state of the equipment, and its operation under normal conditions (humidity and temperature of the environment is not more/ less than that specified in the operating instructions). Transportation costs: The manufacturer is not responsible for the costs of transportation of equipment and spare parts. Cost of works: The manufacturer is not responsible for costs of dismantling and replacement of equipment. Costs of examination: If it is determined that the returned items are not defective and are operable within design standards, the manufacturer reserves the right to receive payment for the examination in the amount of 50 Euro in addition to the transportation costs. THIS CONTRACT WARRANTY EXCLUDES ALL OTHER WARRANTIES OR REPRESENTATIONS, EXPLICIT OR IMPLIED, IN/BY ANY DOCUMENTS, DATA, OR PERSONS. THE MAXIMUM LIABILITY OF THE SUPPLIER UNDE THIS EXCLUSIVE LEGAL REMEDY MAY NOT EXCEED THE COST OF PRODUCTION, AND THE SUPPLIER RESERVES THE RIGHT, IN SOLE DISCRETION, TO REIMBURSE THE COST OF PURCHASED EQUIPMENT INSTEAD OF ITS REPAIR OR REPLACEMENT. THE SUPPLIER IS NOT LIABLE FOR ANY DIRECT, INDIRECT, ASSOCIATED WITH THE PARTICULAR CIRCUMSTANCES OR INCIDENTAL DAMAGES CAUSED BY BREACH OF WARRANTY, OR COMING FROM OTHER LEGAL BASIS, INCLUDING LOST PROFITS, LOSS OF REPUTATION, TIME, INCONVENIENCE, FUEL AND LABOR COSTS, OR OTHER INCIDENTAL OR CONSEQUENTIAL LOSS OR DAMAGE INCURRED BY PERSONS, COMMERCIAL ORGANIZATIONS, OR THEIR PROPERTY, AS A RESULT OF BREACH OF WARRANTY, NEGLIGENCE, AND OTHER CONDITIONS. THIS WARRANTY IS DEFINED AND LIMITED BY THE FOREGOING SPECIFIC CONDITIONS AND IS THE ONLY LEGAL REMEDY. R www.danvex.fi 15

Details of the seller:

Name of the organization:_________________________________________________ __________________________________________________________ Address:__________________________________________________________________ Telephone number:__________________________________________________________ Details of the buyer: Full name (Organization): ____________________________________________________ __________________________________________________________________________ Address:__________________________________________________________________ Telephone number:__________________________________________________________ www.danvex.fi Seal (for the legal person) THE MANUFACTURER DOES NOT GUARANTEE COMPATIBILITY OF THE PURCHASED EQUIPMENT WITH THE EQUIPMENT OF THE BUYER. THE SELLER GUARANTEES SERVICEABILITY OF EACH OF ACCESSORIES SEPARATELY, BUT IS NOT RESPONSIBLE FOR THE QUALITY OF THEIR JOINT FUNCTIONING, EXCEPT WHEN PURCHASED IN THE SET AND INSTALLED ACCORDING TO THE RECOMMENDATIONS OF THE DISTRIBUTOR. IN ACCORDANCE WITH THE LAW OF THE RF “ON PROTECTION OF CONSUMER RIGHTS” AS AMENDED AND THE REGULATIONS OF THE GOVERNMENT OF THE RUSSIAN FEDERATION NO. 55 of JANUARY 19, 1998 "LIST OF NON-FOOD PRODUCTS OF GOOD QUALITY, ARE NOT SUBJECT TO RETURN OR EXCHANGE FOR SIMILAR GOODS OF OTHER SIZE, SHAPE, DIMENSIONS, STYLE, COLOR OR CONFIGURATION" (AS AMENDED ON OCTOBER 20, 1998), THE SELLER IS NOT OBLIGED TO TAKE BACK DEFECTIVE EQUIPMENT IF IT FOR ANY REASONS HAS TURNED OUT TO BE UNSUITABLE FOR THE BUYER. Warranty card shall only be valid if completely filled, in the presence of the seal of the service center or the seller, the signature of the consumer, and in the presence of an act of assembly, issued by the dealer or service center DanVex (for dehumidifiers of AD series, requiring professional installation). R www.danvex.fi 16 ВНИМАНИЕ!!! CAUTION!!!

Other Other Manuals