Sprint Pro Operation & User’s Manual: Key Pages of Document

Multi-function Flue Gas Analyser

T: +44 (0)870 428 0075 www.anton-group.com Sprint Pro 3 5430910000J18 Your company name Your Company Phone ...

Safety and product related information:

• Read and understand all instructions in the operation sec- tion of this manual before use. • Observe all warnings and instructions marked on Sprint Pro, or as prompted by the analyser and within this manual. • Sprint Pro must only be operated with the Sprint Pro Flue Probe assembly and always with the water trap and filters in place. • Connect the Flue Probe Assembly to Sprint Pro before switching on and do not insert probe into flue until after the zeroing process is complete. • Sprint Pro water trap must be dried after use and before Sprint Pro Flue Probe Assembly is returned to carry case. • Spri ...

those containing high concentrations of acetone

and silicone compounds (such as silicone grease). • Do not immerse in water. • Do not use silicon grease on the O-rings. • Fuel options available are: natural gas, LPG, heavy oil, light oil, coal, wood, wood pellet dry, coke, Biomass and Bagasse. Additional information: Sprint Pro is designed to meet the requirements of EN50379-1 and EN50379-3 and to support the work- ing practices defined in British Standard BS7967. It is highly recommended that users are fully conver- sant with BS7967 when using a flue gas analyser for servicing or installing a boiler system. When performing any CO measurements en ...

Sprint Pro Multi-function Flue Gas Analyser .................................. 2

Unpacking ................................................................................................... 2 I. Sprint Pro Orientation ................................................................ 3 Overview ..................................................................................................... 3 Probe connections ....................................................................................... 4 Switch on and using the Menu .................................................................... 4 Switch off ................................. ...

Multi-function Flue Gas Analyser

Thank you for purchasing the Sprint Pro Multi-function Flue Gas Analyser. Sprint Pro will give you years of unparalleled service and reliability if looked after correctly. There are six versions covered in this manual as follows: Sprint Pro 1 Standard model flue gas analyser with CO and O2 sensor Sprint Pro 2 As Pro 1 with pressure and gas escape probe (GEP) capability (available as an option) and upgradability for CO2 and NO measurements Sprint Pro 3 As Pro 2 with a GEP probe included and mobile application connectivity Sprint Pro 4 As Pro 3 with a CO2 room measurement sensor Sprint ...

Sprint Pro Orientation

I. Sprint Pro Orientation Overview Display Showing start-up splash screen ON/OFF/ENTER key Press and hold button for two seconds to switch on and switch off Sprint Pro. Use this key to finish edits, save changes and view next page of multiple paged screens. ESCAPE key Use this button to quit tests and step back through menus. Purge icon Rotating icon shows pump is purging USB connector For charging and communications to PC (Sprint Pro 1 does not offer connectivity to PC) Gas escape probe jack connector IR window Printer output Exhaust exit Warning: do not inhale exit gas exhaust or block exit Thermocouple sockets K-t ...

Sprint Pro Orientation

Sprint Pro Probe connections Flue gas analysis Connect the flue probe to the flue sample inlet and the thermocouple to either K-connector. To measure flue draught pressure connect pressure tube to (-) pressure inlet. Differential pressure, working pressure, operating pressure and let-by and tightness tests (not available on Sprint Pro 1). Connect tubing to pressure inlet(s). Differential temperature test Connect one (or two) thermocouple probes to the K-type connectors. When using one probe, Sprint Pro will display a soft key option to switch between T1 and T2 snapshot measuring points. Gas escape test (not available on Sprint ...

Sprint Pro Orientation

Charging battery It is recommended that Sprint Pro is fully charged before first use. Note: Sprint Pro’s battery must not be charged at temperatures below 0°C or above 40 °C. 1. Plug the USB charger into a mains socket. 2. Connect the charger to the Sprint Pro using the USB-C connector on the unit. 3. Switch on the power at the mains socket. 4. Sprint Pro would normally be left switched off for charging. The display will show the battery charging icon during charging. The battery will recharge in three hours from flat and when fully charged the battery icon will turn green in colour. Please see specification in s ...

Sprint Pro Orientation

Sprint Pro Pump Sprint Pro runs the internal pump during purge and when certain tests are selected, and during and after some tests. A rotating purge icon will appear on the screen when purging. To save on the battery life, Sprint Pro will turn off the pump when it is not required. When the pump is running ensure the exit gas exhaust is not blocked and do not breathe in the exhaust gases. The purge function is often used by Sprint Pro to put clean air over the sensors prior to turning off. This is ideal for realising the full potential lifespan of the sensors, especially the CO sensor filters. Keypad overview Sprint Pro provid ...

Sprint Pro Orientation

The soft keys control the function displayed above them on the screen. These will change depending on the test or menu, or if the ESC key is pressed. To display Sprint Pro serial number, identity and software version press the ESC key from the Main Menu. The menu structure is shown below: Test Menu Main Menu Flue Gas Analysis Gas Escape Detection Room Safety Diff Temperature Pressure Menu (Not available on Sprint Pro 1) Let-by / Tightness Pressure Diff Pressure Working Pressure Operating Pressure Analyser Settings Pressure Units of Measurement Temperature Stored Logs Browse Today’s logs Browse all logs Delete all l ...

Set Up & Menu Configuration Options

Sprint Pro II. Set Up & Menu Configuration Options This section of the manual describes how to change the default configured options if required, if not required please refer to Section III for details on Performing Tests. Fuel options Sprint Pro displays the current fuel option during flue gas testing on the Flue Gas Analysis screen. To change the fuel option required, from the Main Menu select Fuel Options. Use the soft keys and to navigate the available fuels and select the required fuel using the soft key. The new fuel option will be displayed on the Flue Gas Analysis screen during testing. Fuel options avai ...

Set Up & Menu Configuration Options

exceed 100%. Sprint Pro provides a condensing efficiency calculation via the efficiency option NetHE. The result of this calculation takes into account the recovered latent heat. Analyser settings The Analyser settings menu allows you to alter the settings for the display, auto off timeout, back light, key pad and Supervisor settings. To change any of these settings from the Main Menu select Analyser Settings. Use the soft keys and to navigate the available submenus select the required option using the soft key. Auto off timeout The Auto off timeout screen allows the number of minutes at which the Spr ...

Set Up & Menu Configuration Options

Sprint Pro Mobile app Allows turning on or off mobile app functionality. Off: Permanently off On: Permanently on On by report option: Switched on or off as required by selection in Report con- figuration. Note: Report and Mobile app options have an interaction between them, the last option selected will be implemented and the corresponding option may be modified to maintain consistency. Sprint Pro will provide a message indicating a change has been made. Supervisor settings Set time & date On the Time & Date screen the current time and date are shown. Use the soft keys – and + to alter the values of hours, minut ...

Set Up & Menu Configuration Options

CO2 Zero In normal operation Sprint Pro will perform its zeroing function whilst in clean air. However if it is not possible to undertake the zeroing function in clean air then a CO2 scrubber can be utilized. In clean air: Sprint Pro will undertake the zeroing function in clean air and a CO2 scrubber must not be used whilst zeroing. With scrubber: Sprint Pro will undertake the zeroing function in clean air and a CO2 scrubber must be used whilst zeroing. ...

III. Performing tests

Important: Sprint Pro must only be used with the Sprint Pro flue probe assembly and always with the water trap and filters in place. Please ensure the flue probe is connected before switching on your Sprint Pro unit. Ensure the water trap is empty and is fitted in the right direction. Always start in clean air and ensure that the gas exhaust is not blocked. Do not insert the probe into the flue until after the zeroing process is complete. Note: Sprint Pro will switch off the pump when not performing tests or purging. Zeroing process Following Switch on Sprint Pro will require a ‘zero’ before sele ...

1. Flue gas analysis

Before performing the flue gas analysis test, check the water trap is clean and is upright (arrow should point in direction of gas flow). To begin test, select Flue Gas Analysis from the Test Menu. If the zeroing process has not previously been performed Sprint Pro will carry out a 'zero' and then enter the test screen. Check the fuel type displayed on the screen is correct. Use the soft keys to log or print results. Press the ON/OFF/ENTER button to display the screens available: Screen 1: O2, CO, CO2, CO/ CO2 ratio, Pressure. (Not available on Sprint Pro 1) Screen 2: O2, excess (XS) air, Temperatur ...

To perform a pressure zero (not available on Sprint Pro 1), use the soft key

marked P=0 on the relevant screen. To scroll through the efficiency options, use the soft key marked . Note: for personal safety a carbon monoxide (CO) alarm will activate at 350ppm. This will deactivate when CO levels drop below 200ppm. This is to inform the user of potentially hazardous exhaust levels. To end test press the ESC key. Note: The minimum test duration should exceed both the time taken for burners to heat up, during which the CO and NO produced may not be representative of subsequent operation, and also the time needed for the boile ...

6. To stop test press the soft key

. 7. To pass Let-by test, press the soft key to proceed to Stabilisation and Tightness tests. To fail the Let-by test press the key . Use the soft keys to log or print the results as required. To carry out the Let-by test again press and restart from step 2. 8. Press the soft key to start Stabilistion. Sprint Pro displays the duration time on the screen. 9. To stop test press the soft key . 10. Press the soft key to pass the Stabilistion test and proceed to Tightness test. To fail the Stabilistion test press the key . Use the soft keys to log or print the results as required. To carr ...

At the end of the Tightness test use the soft keys to log or

print the results as required. Press the ESC key to return to the Pressure Menu. Press ESC again to return to Test Menu. 3. Pressure, Differential Pressure, Working Pressure and Operating Pressure tests (not available on Pro 1) Before carrying out the test the pressure must be zeroed with the tubes con- nected to Sprint Pro but not to the pressure source. A thermocouple may be connected to provide temperature readings in these tests. 1. Select Pressure Menu from the Test Menu. From the Pressure Menu screen options select Pressure, Differential Pressure, Working ...

Measuring Instruments PDF Instructions

Leica LS10 Manual 
Leica LS10
20.03.2026 10 pages

Leica LS10/LS15 Quick Guide Version 1.0 English

Keysight Technologies M9710A Configuration and measurement instructions
Keysight Technologies M9710A
06.04.2026 16 pages

Configuration and Measurement Instructions Keysight M9710A High-Speed Digitizers Hardware Extension of 89600 VSA Software

ETI 810-195 Operating instructions
ETI 810-195
15.06.2026 2 pages

810-195/30.10.18 THERMA-HYGROMETER Operating Instructions Product code: 810-195 Supplied by Electronic Temperature Instruments Ltd Worthing · West Sussex · BN14 8HQ 01903 202151 · [email protected] · etiltd.com all-guides.c om

Burkert 8032 Operating instructions manual
Burkert 8032
16.05.2026 142 pages

Operating Instructions Bedienungsanleitung Manuel d‘utilisation Type 8032 / 8072 Flowmeter / Flow threshold detector Durchfluss-Messgerät / -Schwellendetektor Débitmètre / Détecteur à seuil du débit