DELTA DORE TYBOX Operation & User’s Manual

Text of the manual

• Carefully read these instructions prior to installation.

• Do not attempt to repair the unit yourself; after-sales service is available. Turn the selector dial to AUTO. Your thermostat will function according to the program. NOTE: According to the configuration during installation, your unit will continuously display the set-point temperature or the temperature of the room. To change these settings, refer to the installation section of these instructions, or contact our customer service department or your installer. In automatic mode, override is used to go from Comfort to Setback mode (or conversely) until the next program change. 6h 8h 0h 0h 15h30 17h 23h This mode is used to choose a set-point temperature that remains constant. Turn the selector dial to . To exit this mode, turn the selector dial. This thermostat lets you program your heating system to Comfort or Setback mode. 1. Presentation 2. Automatic mode 4. Timer mode 5. Continuous mode 6. Absence mode 3. Override TYBOX TYBOX Daily/weekly programmable thermostat User guide Selector dial position Modification buttons Time Current day Example: it is 15:30 and you would like to switch to Comfort mode before the set time (17:00). Current day programming Press the override button. Override currently active Confirm Confirm Confirm Change of the set-point temperature Set-point temperature Confirm Adjustment of the set-point temperature (from 5 to 30°C) Adjustment of the duration from 15 minutes to 72 hours (in increments of 15 minutes) Choice of set-point temperature (from 5 to 30°C) Return to AUTO mode at the end of the countdown At 17:00, the program will return to its usual program. To cancel the current override, press the button once more. Room temperature Current day programming Current mode Display in automatic mode Override Information button Selector dial Shutdown mode Absence mode Timer mode Automatic mode Continuous mode Time setting Programming Set-point temperature adjustment This mode is used to choose a set-point temperature for a given amount of time. Turn the selector dial to . To make changes to the current mode, press OK once more. in corso, premete nuovamente sul tasto OK. To cancel the current timer mode,turn the selector dial. To make changes to the current mode, press OK once more. To cancel the current timer mode, turn the selector dial. This mode lets you place your home under FrostProtection if you need to leave for several days. Turn the selector dial to . Adjustment of the number of days (1 to 365) Example: for a departure on 1 March and a return on 16 March, program 15 days of absence. Automatic operation will resume on 16 Marchat midnight. Adjustment of the set-point temperature (from 5 to 15°C) Confirm and start the calendar countdown. Return to AUTO mode at the end of the countdown Delta Dore hereby declares that the equipment complies with the essential requirements and other relevant provi- sions of the R&TTE Directive 2004/108/CE (Electromagnetic Compatibility) and 2006/95/EC (Low Voltage safety). The EC declaration of conformity for this equipment is available, on request, from: "Technical information" department DELTA DORE - Bonnemain - 35270 Combourg (France) E-mail : [email protected] Because of changes in standards and equipment, the characteristics given in the text and the illustrations of this document are not binding unless confirmed by our services. *2702543_Rev.1*

This mode shuts down your heating system.

Turn the selector dial to . Turn the selector dial to . To exit this mode, turn the selector dial. Turn the selector dial to . The days flash. Press + or - to change the day, then press OK to confirm and continue on to the next setting. Repeat the operations to set the hours and minutes. To leave the “setting the time” mode, turn the selector dial. Turn the selector dial to PROG. The default program is a Comfort period from 6:00 to 23:00. 1. Create your program Programming starts on day 1 at midnight. Press the or buttons to create different Setback or Comfort periods. 2. Confirm and copy the program Press and hold the OK button for 3 seconds to confirm the program you created and copy it to the next day. OR 3. Confirm the program Press the OK button to confirm and continue on to the next day to program it separately. 4. Check your program Press the button repeatedly to check the accuracy of the Comfort and Setback periods you created. Press OK to check the next day. To exit the mode, turn the selector dial to another mode. COMMENTS: Depending on the configuration made during installation, programming can be weekly or daily. Likewise, this programming may be done in increments of one hour, 30 minutes, or 15 minutes. To change these settings, refer to the installation section of these instructions, or contact our customer service department or your installer. In AUTO mode, pressing the i button gives you the temperature of the room or the set-point temperature according to the installation configuration. Nothing is displayed on the room unit screen. There is no power supply or batteries. Check your circuit breaker or your batteries The unit is in time setting mode. There was a mains disruption that lasted more than 2 hours. Set the time. All other settings have remained unchanged. When setting the time,there is no option to set the day. You are in daily programming. To switch to weekly programming, refer to the installation section of these instructions, or contact your installer or our customer service department. When creating a program,the and symbols do not appear on the screen. Changing programs is not allowed. Refer to the installation section of these instructions, or contact your installer or our customer service department. The temperature displayed does not match the temperature measured in the room (thermometer). Refer to the installation section of these instructions or contact your installer or our customer service department. The programs cannot be modified and set-point temperature adjustment is limited (Comfort:16 to 22°C, Setback:13 to 19°C, Frost Protection:5 to 11°C) Refer to the installation section of these instructions or contact your installer or our customer service department. Your heating system is in Frost-Protection mode. The thermostat is in , , PROG o position. - Ensure that the +/- polarities are correctly placed when the battery is fitted into the unit. - Do not dispose of used batteries in unauthorized places (you should respect the environment by taking the batteries to a suitable collection site). - Do not recharge the batteries. - You have approximately 30 seconds to change the batteries before the time is reset to zero (if this happens, reset the date and time). When the battery level symbol appears, you have around 1 month to change the batteries (two 1.5 V alkaline batteries, LR03 or AAA). The following precautions must be respected: 1 2 3 4 7. Shutdown mode 9. Setting the time 10. Programming 10. Programming 11. Information button 12. Replacing batteries (version TYBOX 710-713) 13. Troubleshooting 8. Set-point Temperature Setting Room temperature Configuration menu access button (press and hold for 5 seconds) Adjustment of the Comfort set-point temperature (from 5 to 30°C in increments of 0.5°C) Confirm switch to Setback temperature setting Confirm Adjustment of the Setback set-point temperature (from 5 to 30°C) Set-point temperature display Battery level symbol Separate the thermostat from its support Replace the batteries, making sure they are the right way round Lock the thermostat Position the thermostat on its base Return to normal display (automatic after 2 minutes) Minutes Hours Days (1: Monday… 7: Sunday) Day 1st time slot Time slot consulted Verification of the different or periods Program profile Comfort period adjustment Setback period adjustment If your thermostat displays the temperature of the room 6h 8h 0h 0h 17h 23h E.g. Comfort from 6:00 to 8:00 and from 17:00 to 23:00 Press and hold until you reach 06:00 Press and hold until you reach 17:00 Press and hold until you reach 00:00 Copy and confirm or simply confirm Press and hold until you reach 23:00 Press and hold until you reach 08:00

Other Thermostat Manuals