SAFETY WARNINGS/ISTRUZIONI PER LA SICUREZZA |FOREWORD

TIGER E5 · User Manual · ENG SUMMARY 1. SAFETY WARNINGS/ISTRUZIONI PER LA SICUREZZA 4 FOREWORD 5 2. SAFETY WARNINGS 6 3. CONSIGNES DE SÉCURITÉ IMPORTANTES 8 4. ISTRUZIONI IMPORTANTI PER LA SICUREZZA 10 5. WICHTIGE SICHERHEITSHINWEISE 12 6. INSTRUCCIONES IMPORTANTES DE SEGURIDAD 14 7. UNPACKING AND INSPECTION 16 8. FIRST INSTALLATION RECOMMENDATIONS 17 POWER SUPPLY CABLE 17 PROTECTION AGAINST LIGHTNING 18 VENTILATION 19 9. DEVICE INSTALLATION 19 BEST SETUP LOCATION 19 POWER SUPPLY 19 10. DEVICE GENERAL DESCRIPTION 21 FRONT PANEL 21 REAR PANEL 21 11. FIRST DEVICE START 25 STARTING YOUR TIGER E5 - QUICK SETUP 25 11.1.1 HOME PAGE 26 LOGIN 28 LOGGED IN USER – HOME PAGE 29 SUMMARY MASK 30 SETUP 37 11.5.1 GENERAL SETUP 37 11.5.2 NETWORK 41 11.5.3 NTP 47 11.5.4 SNMP 49 11.5.5 SMTP 56 11.5.6 GPIO 60 11.5.7 GPS 64 11.5.8 SYSTEM TOOLS 65 ADMINISTRATION 68 11.6.1 USER CLASS – USER RIGHTS TO LOGIN THE SYSTEM 70 11.6.2 ADDING A NEW USER 74 11.6.3 REMOVING AN EXISTING USER 75 LOGS 75 11.7.1 DEBUG LOGS 76 11.7.2 USERS LOGS 76 11.7.3 EVENTS LOGS 76 11.7.4 NOTIFICATIONS LOGS 76 CONFIGURATION 76 RDS/RBDS 77 11.9.1 QUICK RDS SETUP 77 11.9.2 UECP PORTS 77 11.9.3 BASIC SETTINGS 83 11.9.4 STANDARD MODE 89 11.9.5 EXTENDED MODE 102 11.9.6 RDS BLOCKS ANALYSIS 109 AUDIO INPUT 110 11.10.1 SOURCES 110

SAFETY WARNINGS/ISTRUZIONI PER LA SICUREZZA |FOREWORD

TIGER E5 · User Manual · ENG 11.10.2 CHANGEOVER 121 11.10.3 AUDIO ANALYSIS 123 TIGER E5 WAYS OF USE 126 11.11.1 SINGLE AUDIO SOURCE WITH RDS GENERATION127 11.11.2 DOUBLE AUDIO SOURCES WITH AUDIO CHANGEOVER 128 11.11.3 MPX REBROADCAST WITH RDS REGENERATION + UECP FILTER ON INCOMING RDS 129 11.11.4 DOUBLE AUDIO SOURCES WITH AUDIO CHANGEOVER. MPX CHANGEOVER WITH MPX BACKUP SOURCE 130 11.11.5 DOUBLE AUDIO SOURCES WITH AUDIO CHANGEOVER. MPX CHANGEOVER WITH MPX MAIN SOURCE 131 11.11.6 RDS GENERATOR CONFIGURATION 132 MPX 132 11.12.1 INTERNAL MPX ENCODER 132 11.12.2 CHANGEOVER 133 11.12.3 OUTPUTS 147 11.12.4 MPX ANALYSIS 148 MULTIMEDIA 150 11.13.1 STREAMER 150 12. WEEE DIRECTIVE – INFORMATIVA RAEE 160 13. WARRANTY 161 14. DECLARATION OF ROHS CONFORMITY 162 15. FINAL CONSIDERATIONS AND AXEL TECHNOLOGY CONTACTS 163

SAFETY WARNINGS/ISTRUZIONI PER LA SICUREZZA |FOREWORD

TIGER E5 · User Manual · ENG 1. SAFETY WARNINGS/ISTRUZIONI PER LA SICUREZZA _____________________________________________________________________________________________________________________ SAFETY WARNINGS CONSIGNES DE SÉCURITÉ IMPORTANTES ISTRUZIONI IMPORTANTI PER LA SICUREZZA WICHTIGE SICHERHEITSHINWEISE INSTRUCCIONES IMPORTANTES DE SEGURIDAD (Rel. 1.6) _____________________________________________________________________________________________________________________

SAFETY WARNINGS/ISTRUZIONI PER LA SICUREZZA |FOREWORD

TIGER E5 · User Manual · ENG FOREWORD _____________________________________________________________________________________________________________________ For your own safety and to avoid invalidation of the warranty all text marked with these Warning Symbols should be read carefully. _____________________________________________________________________________________________________________________ Information in this manual is subject to change without notice and does not represent a commitment on the part of the vendor. The manufacturer shall not be liable for any loss or damage whatsoever arising from the use of information or any error contained in this manual, or through any mis-operation or fault in hardware contained in the product. It is recommended that all maintenance and service on the product should be carried out by the manufacturer or its authorised agents. The manufacturer cannot accept any liability whatsoever for any loss or damage caused by service, maintenance or repair by unauthorised personnel

SAFETY WARNINGS |FOREWORD

TIGER E5 · User Manual · ENG 2. SAFETY WARNINGS The installation and servicing instructions in this manual are for use by qualified personnel only. - Read All Instructions. All safety and operating instructions must be read before operating the product. They also must be retained for future reference, as it contains a number of useful hints for determining the best combination of equipment settings for Yr particular application. - Heed All Warnings. All warnings on the product and those listed in the operating instructions must be adhered to. - Heat. This product must be situated away from any heat sources such as radiators or other products (including power amplifiers or transmitters) that produce heat. - Power Sources. This product must be operated from the type of power source indicated on the marking label and in the installation instructions. If you are not sure of the type of power supplied to your facility, consult your local power company. Make sure the AC main voltage corresponds to that indicated in the technical specifications. If a different voltage (ex. 110/115 VAC) is available, open the equipment closure and set the voltage switch on the main supply circuit, located behind the AC socket - Power Cord Protection. Power supply cords must be routed so that they are not likely to be walked on nor pinched by items placed upon or against them. Pay particular attention to the cords at AC wall plugs and convenience receptacles, and at the point where the cord plugs into the product - Use only with a cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over. - Lightning. For added protection for this product during a lightning storm, or when it is left unattended and unused for long periods of time, unplug it from the AC wall outlet and the audio connections. This will prevent damage to the product due to lightning and power line surges - Installation. Configuration and installation should only be carried out by a competent installation engineer - Cabling. Using high quality wires, well protected. Make sure the cable integrity.

SAFETY WARNINGS |FOREWORD

TIGER E5 · User Manual · ENG This symbol alerts you to the presence of dangerous voltage inside the closure – voltage which may be sufficient to constitute a risk of shock. Do not perform any servicing other than that contained in the operating instructions. Refer all servicing to qualified personnel The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance. Do not change the voltage setting or replace the mains fuse without first turning the unit off and unplugging the mains cord Make sure the AC main voltage corresponds to that indicated in the technical specifications. THIS APPARATUS MUST BE EARTHED ! To avoid risk of fire use the correct value fuse, as indicated on the label stuck on the right side of the unit. This apparatus uses a single pole mains switch and does therefore not separate the unit completely from the mains power. To completely separate from mains power (f.i. in the event of danger) unplug mains power cord. As the MAINS plug is the disconnect device, the disconnect device shall remain readily operable.

CONSIGNES DE SÉCURITÉ IMPORTANTES |FOREWORD

TIGER E5 · User Manual · ENG 3. CONSIGNES DE SÉCURITÉ IMPORTANTES - Lire ces consignes - Conserver ces consignes - Observer tous les avertissements - Suivre toutes les consignes - Ne pas utiliser cet appareil à proximité de l’eau - Ne pas obstruer les ouvertures de ventilation. Installer en respectant les consignes du fabricant - Ne pas installer à proximité d'une source de chaleur telle qu'un radiateur, une bouche de chaleur, un poêle ou d'autres appareils (dont les amplificateurs) produisant de la chaleur. - Ne pas annuler la sécurité de la fiche de terre, la troisième branche est destinée à la sécurité. Si la fiche fournie ne s'adapte pas à la prise électrique, demander à un électricien de remplacer la prise hors normes. - Protéger le cordon d'alimentation afin que personne ne marche dessus et que rien ne le pince, en particulier aux fiches, aux prises de courant et au point de sortie de l’appareil - Utiliser uniquement les accessoires spécifiés par le fabricant - Utiliser uniquement avec un chariot, un support ou une table spécifié par le fabricant ou vendu avec l’appareil. Si un chariot est utilisé, déplacer l’ensemble chariot–appareil avec précaution afin de ne pas le renverser, ce qui pourrait entraîner des blessures - Débrancher l’appareil pendant les orages ou quand il ne sera pas utilisé pendant longtemps. - Confier toute réparation à du personnel qualifié. Des réparations sont nécessaires si l’appareil est endommagé d’une façon quelconque, par exemple: cordon ou prise d’alimentation endommagé, liquide renversé ou objet tombé à l’intérieur de l’appareil, exposition de l’appareil à la pluie ou à l’humidité, appareil qui ne marche pas normalement ou que l’on a fait tomber. - NE PAS exposer cet appareil aux égouttures et aux éclaboussements. Ne pas poser des objets contenant de l'eau, comme des vases, sur l'appareil

CONSIGNES DE SÉCURITÉ IMPORTANTES |FOREWORD

TIGER E5 · User Manual · ENG Ce symbole indique la présence d'une tension dangereuse dans l'appareil constituant un risque de choc électrique. Ce symbole indique que la documentation fournie avec l'appareil contient des instructions d'utilisation et d'entretien importantes. Avant de modifier le commutateur de changement de tension ou replacer le fusible il faut débrancher l’appareil de la prise électrique. Pendant son usage, l’appareil doit etre branchee à la prise de terre Utiliser le fusible principal AC avec le valeur qui est indiquée sur l'étiquette collée sur le coffret Assurez-vous que la tension principale AC correspond à celle indiquée dans les spécifications techniques. L’interrupteur d’alimentation interrompt un pôle du réseau d’alimentation excepté le conducteur de terre de protection. En cas de danger, debrancher le cordon d'alimentation. Parce que la prise du réseau de alimentation est utilisée comme dispositif de déconnexion, ce dispositif doit demeuré aisément accessible

ISTRUZIONI IMPORTANTI PER LA SICUREZZA |FOREWORD

TIGER E5 · User Manual · ENG 4. ISTRUZIONI IMPORTANTI PER LA SICUREZZA - Leggere le presenti istruzioni - Conservare queste istruzioni - Osservare tutte le avvertenze - Seguire scrupolosamente tutte le istruzioni - Non usare questo apparecchio in prossimità di acqua - Non ostruire alcuna apertura per il raffreddamento. Installare l’apparecchio seguendo le istruzioni - Non installare l'apparecchio accanto a fonti di calore quali radiatori, aperture per l'afflusso di aria calda, forni o altri apparecchi (amplificatori inclusi) che generino calore - Non rimuovere il terminale di connessione a terra sul cordone di alimentazione: esso ha lo scopo di tutelare l’incolumità dell’utilizzatore. Se la spina in dotazione non si adatta alla presa di corrente, rivolgersi ad un elettricista per far eseguire le modifiche necessarie. - Evitare di calpestare il cavo di alimentazione o di comprimerlo, specialmente in corrispondenza della spina e del punto di inserzione sull’apparato. - Utilizzare solo dispositivi di collegamento e gli accessori specificati dal produttore. - Utilizzare l’apparecchio solo con un carrello, un sostegno, una staffa o un tavolo di tipo specificato dal produttore o venduto insieme all’apparecchio. Se si utilizza un carrello, fare attenzione negli spostamenti per evitare infortuni causati da ribaltamenti del carrello stesso. - Scollegare l’apparecchio dalla presa di corrente durante i temporali o quando inutilizzato a lungo - Per qualsiasi intervento, rivolgersi a personale di assistenza qualificato. È’ necessario intervenire sull’apparecchio ogniqualvolta si verificano danneggiamenti di qualsiasi natura. Ad esempio, la spina o il cavo di alimentazione sono danneggiati, è entrato liquido nell’apparecchio o sono caduti oggetti su di esso, l’apparecchio è stato esposto alla pioggia o all’umidità, non funziona normalmente o è caduto. - Non esporre a sgocciolamenti o spruzzi. Non appoggiare sull'apparecchio oggetti pieni di liquidi, ad esempio vasi da fiori.

ISTRUZIONI IMPORTANTI PER LA SICUREZZA |FOREWORD

TIGER E5 · User Manual · ENG Questo simbolo indica la presenza di alta tensione all'interno dell'apparecchio, che comporta rischi di scossa elettrica. Questo simbolo indica la presenza di istruzioni importanti per l'uso e la manutenzione nella documentazione in dotazione all'apparecchio. Non sostituire il fusibile o cambiare la tensione di alimentazione senza aver prima scollegato il cordone di alimentazione. L’APPARATO DEVE ESSERE CONNESSO A TERRA. Sostituire il fusibile generale con uno di identico valore, come indicato sulla etichetta applicata sul mobile dell’apparato Assicurarsi che la tensione di rete corrisponda a quella per la quale è configurato l’apparecchio Questo apparato utilizza un interruttore di alimentazione di tipo unipolare e l’isolamento dalla rete elettrica non è pertanto completo. Per ottenere un isolamento totale (ad esempio in caso di pericolo), scollegare il cordone di alimentazione. Inoltre, poichè la spina di alimentazione è utilizzata come dispositivo di sezionamento, essa deve restare facilmente raggiungibile

WICHTIGE SICHERHEITSHINWEISE |FOREWORD

TIGER E5 · User Manual · ENG 5. WICHTIGE SICHERHEITSHINWEISE - Diese Hinweise LESEN - Diese Hinweise AUFHEBEN - Alle Warnhinweise BEACHTEN - Alle Anweisungen BEFOLGEN - Dieses Gerät NICHT in der Nähe von Wasser verwenden - KEINE Lüftungsöffnungen verdecken. Gemäß den Anweisungen des Herstellers einbauen - Nicht in der Nähe von Wärmequellen, wie Heizkörpern, Raumheizungen, Herden oder anderen Geräten (einschließlich Verstärkern) installieren, die Wärme erzeugen - Die Schutzfunktion des Schukosteckers NICHT umgehen. Bei Steckern für die USA gibt es polarisierte Stecker, bei denen ein Leiter breiter als der andere ist; US- Stecker mit Erdung verfügen über einen dritten Schutzleiter. Bei diesen Steckerausführungen dient der breitere Leiter bzw. der Schutzleiter Ihrer Sicherheit. Wenn der mitgelieferte Stecker nicht in die Steckdose passt, einen Elektriker mit dem Austauschen der veralteten Steckdose beauftragen - VERHINDERN, dass das Netzkabel gequetscht oder darauf getreten wird, insbesondere im Bereich der Stecker, Netzsteckdosen und an der Austrittsstelle vom Gerät - NUR das vom Hersteller angegebene Zubehör und entsprechende Zusatzgeräte verwenden. - NUR in Verbindung mit einem vom Hersteller angegebenen oder mit dem Gerät verkauften Transportwagen, Stand, Stativ, Träger oder Tisch verwenden. Wenn ein Transportwagen verwendet wird, beim Verschieben der Transportwagen-Geräte- Einheit vorsichtig vorgehen, um Verletzungen durch Umkippen - Das Netzkabel dieses Geräts während Gewittern oder bei längeren Stillstandszeiten aus der Steckdose ABZIEHEN. - Alle Reparatur- und Wartungsarbeiten von qualifiziertem Kundendienstpersonal DURCHFÜHREN LASSEN. Kundendienst ist erforderlich, wenn das Gerät auf irgendwelche Weise beschädigt wurde, z.B. wenn das Netzkabel oder der Netzstecker beschädigt wurden, wenn Flüssigkeiten in das Gerät verschüttet wurden oder Fremdkörper hineinfielen, wenn das Gerät Regen oder Feuchtigkeit ausgesetzt war, nicht normal funktioniert oder fallen gelassen wurde. - Dieses Gerät vor Tropf- und Spritzwasser SCHÜTZEN. KEINE mit Wasser gefüllten Gegenstände wie zum Beispiel Vasen auf das Gerät STELLEN.

WICHTIGE SICHERHEITSHINWEISE |FOREWORD

TIGER E5 · User Manual · ENG Dieses Symbol zeigt an, dass gefährliche Spannungswerte, die ein Stromschlagrisiko darstellen, innerhalb dieses Geräts auftreten Dieses Symbol zeigt an, dass das diesem Gerät beiliegende Handbuch wichtige Betriebs- und Wartungsanweisungen enthält. Vor Änderung der Netzspannung oder Sicherungswechsel Netzkabel trennen. Das Gerät muss für den Betrieb geerdet werden. Hauptsicherung nur mit einer gleichwertigen austauschen (s. entsprechende Etikette). Vor Einschalten Netzspannungseinstellung am Gerät überprüfen bzw. anpassen. Inpoliger Netzschalter. In Notfälle oder für Wartungsarbeiten Netzkabel trennen. Der Netzstecker fungiert auch als Trennelement muss deshalb zugänglich bleiben

INSTRUCCIONES IMPORTANTES DE SEGURIDAD |FOREWORD

TIGER E5 · User Manual · ENG 6. INSTRUCCIONES IMPORTANTES DE SEGURIDAD - LEA estas instrucciones - CONSERVE estas instrucciones - PRESTE ATENCION a todas las advertencias. - SIGA todas las instrucciones - NO utilice este aparato cerca del agua - NO obstruya ninguna de las aberturas de ventilación. Instálese según lo indicado en las instrucciones del fabricante - No instale el aparato cerca de fuentes de calor tales como radiadores, registros de calefacción, estufas u otros aparatos (incluyendo amplificadores) que produzcan calor - NO anule la función de seguridad del enchufe polarizado o con clavija de puesta a tierra. Un enchufe polarizado tiene dos patas, una más ancha que la otra. Un enchufe con puesta a tierra tiene dos patas y una tercera clavija con puesta a tierra. La pata más ancha o la tercera clavija se proporciona para su seguridad. Si el toma corriente no es del tipo apropiado para el enchufe, consulte a un electricista para que sustituya el toma corriente de estilo anticuado - PROTEJA el cable eléctrico para evitar que personas lo pisen o estrujen, particularmente en sus enchufes, en los toma corrientes y en el punto en el cual sale del aparato - UTILICE únicamente los accesorios especificados por el fabricante - UTILICESE únicamente con un carro, pedestal, escuadra o mesa del tipo especificado por el fabricante o vendido con el aparato. Si se usa un carro, el mismo debe moverse con sumo cuidado para evitar que se vuelque con el aparato - DESENCHUFE el aparato durante las tormentas eléctricas, o si no va a ser utilizado por un lapso prolongado. - TODA reparación debe ser llevada a cabo por técnicos calificados. El aparato requiere reparación si ha sufrido cualquier tipo de daño, incluyendo los daños al cordón o enchufe eléctrico, si se derrama líquido sobre el aparato o si caen objetos en su interior, si ha sido expuesto a la lluvia o la humedad, si no funciona de modo normal, o si se ha caído. - NO exponga este aparato a chorros o salpicaduras de líquidos. NO coloque objetos llenos con líquido, tales como floreros, sobre el aparato .

INSTRUCCIONES IMPORTANTES DE SEGURIDAD |FOREWORD

TIGER E5 · User Manual · ENG Este símbolo indica que la unidad contiene niveles de voltaje peligrosos que representan un riesgo de choques eléctricos. Este símbolo indica que la literatura que acompaña a esta unidad contiene instrucciones importantes de funcionamiento y mantenimiento. Antes de cambiar la alimentacion de voltaje o de cambiar el fusible, desconecte el cable de alimentacion. Para reducir el riesgo de descargas electricas, esta unidad debe ser conectada a tierra. Remplaze el fusible con lo mismo, que corresponde a lo indicado en el panel del equipo. Antes de encender, controlar que la linea de alimentacion de voltaje corresponda a la indicada El interruptor de alimentación es unipolar. En el caso de peligro, desconecte el cable de alimentación. Porque la clavija de conexion a red sirve por la desconection de la unidad, la clavija debe ser ubicada en proximidad de la unidad

UNPACKING AND INSPECTION |FOREWORD

TIGER E5 · User Manual · ENG 7. UNPACKING AND INSPECTION Your equipment was packed carefully at the factory in a container designed to protect the unit during shipment. Nevertheless, we recommend making a careful inspection of the shipping carton and the contents for any signs of physical damage. Damage & Claims If damage is evident, do not discard the container or packing material. Contact your carrier immediately to file a claim for damages. Customarily, the carrier requires you, the consignee, to make all damage claims. It will be helpful to retain the shipping documents and the waybill number. Save all packing materials! If You should ever have to ship the unti (e.g. for servicing), it is best to ship it in the original carton with its packing materials because both the carton and packing material have been carefully designed to protect the unit. Under normal conditions no user maintenance or calibration are required. Internal links and preset controls may be set to configure the unit during installation. Any service work required should be carried out by qualified service personnel only. We are able to offer further product support through our worldwide network of approved dealers and service agents. To help us provide the most efficient service please would you keep a record of the unit serial number, and date and place of purchase to be quoted in any communication regarding this product. The actual equipment Serial Number is indicated on the silver label stuck on the rear panel of the equipment closure. Tools And Equipment Needed Only standard technician’s tools are required to install this equipment

FIRST INSTALLATION RECOMMENDATIONS |POWER SUPPLY CABLE

TIGER E5 · User Manual · ENG 8. FIRST INSTALLATION RECOMMENDATIONS POWER SUPPLY CABLE A power supply cable of approx. 2 mt length is supplied with the device, which has a moulded IEC plug attached – this is a legal requirement. The type of plug for the power supply depends on the country in which it is delivered. If for any reason, you need to use this appliance with a different plug, you should use the following wiring guidelines in replacing the exsisting plug with the new one: Earth Green, or green and yellow Neutral (N) Blue Live (L) Brown Supply cables should be laid in such a manner that one does not step or walk on them. They should not be squashed by any objects. THIS EQUIPMENT MUST BE EARTHED. The chassis is always connected to mains earth to ensure your safety: check your mains wiring and earthing before switching on.

FIRST INSTALLATION RECOMMENDATIONS |PROTECTION AGAINST LIGHTNING

TIGER E5 · User Manual · ENG PROTECTION AGAINST LIGHTNING Should the device be put out of action due to being struck by lightning or excess voltage, disconnect it from the power supply without delay. Do not reconnect until the device has been checked. If in doubt contact the technical support service. Make sure there is suitable lightning protection to protect the device. Alternatively you should disconnect all connectors from the device during a storm or when the device is going to be unsupervised or not used for a longer period of time. These measures will protect against damage by lightning or excess voltage.

DEVICE INSTALLATION |VENTILATION

TIGER E5 · User Manual · ENG VENTILATION The equipment will operate as a free-standing unit without requiring any special cooling arrangement. However, slots and openings in the product are provided for ventilation. They ensure reliable operation of the product, keeping it from overheating. These openings must not be blocked nor covered during operation. YOU MUST LEAVE AT A MINIMUM ONE RACK UNIT OF EMPTY SPACE ABOVE THE EQUIPMENT TO ENHANCE VENTILATION AND TO GET A LONGER EQUIPMENT LIFE. 9. DEVICE INSTALLATION BEST SETUP LOCATION The device should be installed in a 19” rack. Avoid direct sunlight, close proximity to radiators and air conditioning, dust, water, and chemicals. Choose a rack location that permits a clear view to the indicators on the device and ensure a sufficient heat dissipation of the device. POWER SUPPLY The device is designed for operation with 100 to 240 V AC, 50 Hz to 60 Hz. Check the corresponding device labelling for compatibility to the domestic line voltage and frequency before connecting the IEC power connector to the mains supply! WARNING Disconnect mains power plug before you open the housing. Repair of the equipment must only be carried out by authorized and qualified personnel.

DEVICE INSTALLATION |POWER SUPPLY

TIGER E5 · User Manual · ENG 1 Power Supply Please make sure that the device and the contained fuse(s) (please see p. 20) are compatible to the domestic line voltage and frequency. If the device is compatible, connect the power supply cord fully to the IEC power connector at the rear side of the device and a mains power outlet. The “LCD Screed” will then turn on. 2 Network configuration For delivery, the device is configured with default settings for the first connection via the IP interface. 3 Connect to network Connect a network patch cable to the “10/100-Base-T” connector on the rear side of the device and your existing IP network. 4 Web interface The device can be fully operated with an internet browser via the integrated web interface. Use a computer that is connected to the same IP network that the Tiger E5 device is connected to. Start an internet browser, Firefox/Mozilla >V2.0 Google Chrome both with Java Script activated and enter the configured IP address in the address bar of the browser. If the IP address has not been changed in step 2, please enter the default address in the address bar of the browser: 192.168.XXX.XXX. 5 Ready! These first steps are only intended for a quick first start and do not cover all device functions. Pease read carefully the entire manual to be able to use all functions of the device. 6 Important note on the Username and password The equipment comes out from Axel Technology with a standard username: admin and password: admin Each time a NEW user, with administration rights is created, the user admin disappear and it is replaced by the new one just created. If all users are deleted, the standard admin – admin comes out again

DEVICE GENERAL DESCRIPTION |FRONT PANEL

TIGER E5 · User Manual · ENG 10. DEVICE GENERAL DESCRIPTION FRONT PANEL TIGER E5 • Mechanical Steel, 1U - 19 " rack standard. • 40 Led Alarms • USB Port - Type A. REAR PANEL TIGER E5 • Universal Power Supply 90Vac - 240Vac 50/60Hz

DEVICE GENERAL DESCRIPTION |REAR PANEL

TIGER E5 · User Manual · ENG • 2 BNC input connectors: AUX-1 and AUX-2. • 2 BNC output connectors: OUT-1 and OUT-2 • 2 Analog mono input

DEVICE GENERAL DESCRIPTION |REAR PANEL

TIGER E5 · User Manual · ENG • 1 Digital stereo input • USB port - Type A • SD Card Slot

DEVICE GENERAL DESCRIPTION |REAR PANEL

TIGER E5 · User Manual · ENG • LAN/WAN Ethernet port • GPIO Port with 6 optocouplers and 4 relay on DB 25. • 2 serial ports RS232 on DB9 + DB25

FIRST DEVICE START |STARTING YOUR TIGER E5 - QUICK SETUP

TIGER E5 · User Manual · ENG 11. FIRST DEVICE START After important setting changes we suggest you always to reboot the device (In example: after a device upgrade, or changes on IP address). STARTING YOUR TIGER E5 - QUICK SETUP Turn ON the TIGER E5 device with the power switch, on the rear panel: Connect the device to your LAN with an ETHERNET CABLE. Your device could be controlled by one of the following methods (1 or 2). 1. The device could be controlled by a web page on your browser. In the address field of your browser, type the default IP address: 192.168.0.10. You will see the Home Page: 2. We provided you a little WIFI USB KEY. Connect it inside one of the USB ports of the device. If you have more than a WIFI USB KEY connect once a time: a. Search for the following WIFI connection with your mobile phone, tablet or WIFI pc: Config_AP b. Connect to Config_Ap c. The password is 12345678 d. The device could be controlled by a web page on one of your browsers. Open a browser inside your mobile phone, tablet or wifi pc and in the address field type whatever URL you want. N.B., do not type any https URLs.

FIRST DEVICE START |STARTING YOUR TIGER E5 - QUICK SETUP

TIGER E5 · User Manual · ENG 11.1.1 HOME PAGE In the previous screen you can read for some parameters of your device. To see all parameters and to change them you have to login with an apposite Username and password. Click LOGIN at top-right. The equipment comes out from Axel Technology with a standard username – the default admin: Username: admin (case sensitive) password: admin (case sensitive)

FIRST DEVICE START |STARTING YOUR TIGER E5 - QUICK SETUP

TIGER E5 · User Manual · ENG NB: Each time a NEW user, with administration rights is created, the user admin disappears and it is replaced by the new one just created. If all users are deleted, the default admin comes out again, in order to create and enter the device settings In the following mask click on Go to Quick Setup Menu: At the first start the following mask will open automatically, click on Go to Quick Setup Menu: To confirm click on Confirm

FIRST DEVICE START |LOGIN

TIGER E5 · User Manual · ENG Go down in the page, read the instructions until the end of the page and fill all the parameters. You can set all the most important RDS Parameters You can set all the most important RDS Parameters. In this way you can be immediately ONAIR with your RDS. We suggest you to change device Network Ip Address and to create the Users you need. LOGIN You will see the Login mask as shown in this picture: In the first field type for your Username, and in the second one type for the Password. Than click on Login. If you see the following message you typed a wrong Username or a wrong Password. Type them again and retry

FIRST DEVICE START |LOGGED IN USER – HOME PAGE

TIGER E5 · User Manual · ENG LOGGED IN USER – HOME PAGE Once you are logged, you will see the home page as shown in the following picture. The left-tree menu could be different for different user classes:

FIRST DEVICE START |SUMMARY MASK

TIGER E5 · User Manual · ENG SUMMARY MASK At the top of the page you can see a fast summary mask with all the current parameters and warnings as shown in the following picture: SYSTEM Email enabled Scheduler LED. The scheduler is ON LOG status LED. Extended RDS status LED. To enable/disable this Led go to RDS/RBDS>Basic Settings > Rds Settings>Rds Global Extended Mode ALARMS The system is ok. The change should be done in Setup>SMTP>SMTP On DATE & TIME Here you can view Date and Time Enable/Disable a GPS device. To enable/disable it go to Setup>GPS>General Settings>GPS On

FIRST DEVICE START |SUMMARY MASK

TIGER E5 · User Manual · ENG Enable Disable a NTP Server. To enable/disable it go to Setup>NTP>Ntp On Enable/Disable the UTC(Coordinated Universal Time). To enable/disable it enable the NTP or enable the GPS and go to SETUP>GPS>Get UTC from GPS. EXTERNAL FEED RSS FEED Led Status. In this picture example it is disabled. SAMBA server Led Status REST Api Led Status, to change it go to SETUP>General Setup>REST Settings>Active. In this picture example it is disabled. TCPIP-UDP-RS232-SNMP TCPIP: you can connect the device to a maximum of 4 TCP/IP devices. The related led lights up when UECP packets are received. SERIALS: you can connect the device to a maximum of 2 Serial devices. The related led lights up when UECP packets are received. UDP: you can connect the device to a maximum of 4 UDP devices. The related led lights up when UECP packets are received. SNMP: The led lights up when SNMP UECP packets are received.

FIRST DEVICE START |SUMMARY MASK

TIGER E5 · User Manual · ENG GPIO GPO: You can connect the device to a maximum of 4 GPO devices(GPO1, GPO2, GPO3, GPO4). These LEDs indicate status of the related GPO device. To set GPO settings go in Setup>GPIO>GPO(1/2/3/4) and in Setup>GPO>GPO Event Notification. GPO1, GPO2, GPO3, GPO4. GPI: you can connect a maximum of 6 GPI devices. These LEDs light up when the related GPI device is turned on. SYSTEM DATA Here you can view the statistics connected with the system. CPU usage, Memory usage, and system temperature. RDS SIGNAL RDS output signal intensity in mV(millivolt peak to peak). RDS/RDBS>Rds Settings>Rds Levels Phase Synchronism between Rds signal and pilot frequency. Int: internal pilot managed by the Tiger E5, RDS/RDBS>Rds Synchronism ON AIR GROUPS Here you can view RDS group sequence.

FIRST DEVICE START |SUMMARY MASK

TIGER E5 · User Manual · ENG PS-DS-PI-DI PS (Program Station) NAME Here you can read the aired DATASET number to change it go to RDS/RBDS>Active Dataset Selection>On Air Active Dataset. PS, PI, PTY-PTYN, DI depend on the selected Dataset. To change them go to RDS/RBDS>(UECP Main/UECP Eon)PS DI (Decoder Information). PI(Program Identifier) PTYN-PTY PTY (Program Type) – PTYN (Program Type Name) RADIOTEXT & RDS SERVICES Here you can view the set RadioText and all the active services RDS/GROUPS STATISTIC Here you can view a rotation with the statistics of the active groups.

FIRST DEVICE START |SUMMARY MASK

TIGER E5 · User Manual · ENG SOURCES LABEL To assign a label here go to MPX > Changeover > Source A > MPX Mixer > Reference Label To assign a label here go to MPX > Changeover > Source B > MPX Mixer > Reference Label MPX-SOURCES Go to MPX > Changeover > Source A > MPX Source A Validation to turn on the Validation Controls. Yellow is valid, red is invalid. Go to MPX > Changeover > Source B > MPX Source B Validation to turn on the Validation Controls. Yellow is valid, red is invalid. From this Led Meters you can see the Source A levels and the Source B levels MPX-CHANGEOVER Go to MPX > Changeover > Delay / Mode to change the Changeover section MPX SIGNAL OUTPUT Go to MPX > Outputs > MPX Output 1 > Source Go to MPX > Outputs > MPX Output 2 > Source Go to MPX > Internal MPX Encoder > Preemphasis From this Led Meters you can see the MPX Output levels

FIRST DEVICE START |SUMMARY MASK

TIGER E5 · User Manual · ENG ON AIR MPX SIGNAL Here you can see which parts of the MPX Signal you are sending. To change this go in MPX > Outpits > MPX Output 1 > Source HEADPHONES Here you can set the Headphones level and the Source. To change the Headphone Source click on the SRC button SOURCES & PRIORITY Here you can have an overview on the 4 audio sources and levels of the audio changeover. To change 1SRC an 2SRC go to Audio Input > Changeover > Sources > Source 1 and to Audio Input > Changeover > Sources > Source 2 Here you can have an overview on the 4 audio sources and levels of the audio changeover. To change 3SRC an 4SRC go to Audio Input > Changeover > Sources > Source 3 and to Audio Input > Changeover > Sources > Source 4 AUDIO CHANGEOVER Go to Audio Input > Changeover > Audio Changeover > Configuration > Mode to select the Audio Changeover Mode. Go to Audio Input > Changeover > Audio Changeover > Sources to select the Sources for the Source1, Source2, Source3, Source4 AUDIO MODULE OUTPUT Go to Audio Input > Changeover > Audio Changeover > Configuration > Mode to select the Audio Changeover Mode. Go to Audio Input >

FIRST DEVICE START |SUMMARY MASK

TIGER E5 · User Manual · ENG Changeover > Audio Changeover > Sources to select the Sources for the Source1, Source2, Source3, Source4 SOURCES MONITOR OUTPUT Go to Audio Input > Sources > Output Monityor > Output Sources Monitor > Configuration > Audio Monitor Sources If you resize your browser press the button to open the following navigation menu:

FIRST DEVICE START |SETUP

TIGER E5 · User Manual · ENG SETUP By clicking on setup you can see all the available setup subpages as shown in the following picture: 11.5.1 GENERAL SETUP In Setup > General Setup you have different general parameters to start device setup: Target References Host Name Prefix: default field with the Product Name. This parameter is unchangable Host Name Custom: customizable parameter. Type here the desired device name. This parameter helps you to recognize the device in your computer network. Host Name: Host Name Prefix(fixed value) + Host Name Custom Target Name Ref.: Type here a desired name for the device Target Location Ref.: Type here the device location Target Operator Ref.: Type here the Operator name

FIRST DEVICE START |SETUP

TIGER E5 · User Manual · ENG Other Settings Language: Select here the desired device language Http Bandwidth: Select here between Gprs, Low, Normal or High bandwidth Local Time Zone: Select from the dropdown menu the desired Time Zone REST Settings Active: Check/Uncheck this box if you want to activate/deactivate the REST API for the device Port: Type the REST API port

FIRST DEVICE START |SETUP

TIGER E5 · User Manual · ENG SMB/SAMBA Share Settings This folder helps you to air TITLE and SONGS datas via RDS directly from your playout software Active: Check/Uncheck this parameter to activate/deactivate the control on the playout folder Hostname IP / URL: Type here the IP/URL of the Playout PC Smb/Samba Share: Type here the playout xml path User Name: Type here the PC / Folder Username Password: Type here the PC / Folder Password Masked/Unmasked: decide here if you want to mask/unmask the Alarms related with the connectivity with the PC / Folder. If you see SMB/SAMBA Alarms something is wrong wit the IP/URL, or USERNAME and PASSWORD

FIRST DEVICE START |SETUP

TIGER E5 · User Manual · ENG Target Localization Manual Target Coordinates: Check/Uncheck this parameter to activate/deactivate the Manual Target Coordinates insertion. Latitude: Latitude insertion is activated when Manual Target Coordinates is checked. Type here the manual latitude Longitude: Longitude insertion is activated when Manual Target Coordinates is checked. Type here the manual longitude Marker Baloon Field: Insert here what you want to read on the map Marker Baloon at the selected coordinates. Manual Target Clock Synchronization Synchronize Target with Client Clock: synchronizes the clock with the client pc clock

FIRST DEVICE START |SETUP

TIGER E5 · User Manual · ENG 11.5.2 NETWORK In Setup > Network>ethx you have different parameters to set configurations for the device network connection and addressing: Mac Address MacAddress: Here the Super Technician can type the device Mac Address. In General Configuration you can read for all the current network settings. IPv4 Addressing IPv4 Addressing Method: choose here the Addressing Method. You can choose between Manual or DHCP(auto). Manual: if you choose Manual you have to insert all IPv4 and DNS IPv4 datas. DHCP(auto): a DHCP (Dynamic Host Configuration Protocol) server dynamically distributes network configuration parameters. IPv4 enable: check this parameter to enable/disable the IPv4 network addressing. IPv6 Addressing

FIRST DEVICE START |SETUP

TIGER E5 · User Manual · ENG IPv6 Addressing Method: choose here the Addressing Method. You can choose between Manual or DHCP(auto). Manual: if you choose Manual you have to insert all IPv6 and DNS IPv6 datas. DHCP(auto): a DHCP (Dynamic Host Configuration Protocol) server dynamically distributes network configuration parameters. IPv6 enable: check this parameter to enable/disable the IPv4 network addressing. In the following setting sections you can fill all the desired IP datas if you have set Manual Addressing Method: Primary IPv4 Additional #1 IPv4 Additional #2 IPv4

FIRST DEVICE START |SETUP

TIGER E5 · User Manual · ENG Primary IPv6 Additional #1 IPv6 Additional #2 IPv6

FIRST DEVICE START |SETUP

TIGER E5 · User Manual · ENG DNS IPv4 Enable(Primary DNS IPv4): If it is needed, click on the checkbox to enable a Primary DNS IPv4 Primary DNS(IPv4): type here the IP of the desired DNS server Enable(Additional #1 DNS IPv4): Check it to enable the first additional DNS IPv4 Server Additional #1 DNS(IPv4): type the IP of the DNS server Enable(Additional #2 DNS IPv4): Check it to enable the second additional DNS IPv4 Server Additional #2 DNS(IPv4): type the IP of the DNS server. DNS IPv6 Enable(Primary DNS IPv6): If it is needed, click on the checkbox to enable a Primary DNS IPv6 Primary DNS(IPv6): type here the IP of the desired DNS server Enable(Additional #1 DNS IPv6): Check it to enable the first additional DNS IPv6 Server Additional #1 DNS(IPv6): type the IP of the DNS server Enable(Additional #2 DNS IPv6): Check it to enable the second additional DNS IPv6 Server Additional #2 DNS(IPv6): type the IP of the DNS server.

FIRST DEVICE START |SETUP

TIGER E5 · User Manual · ENG CONFIGURATION Send Network Configuration: By clicking on this button you send the new network configuration. To confirm the process you have to connect to the new set IP and you have to press the following button. Confirm Network Configuration: If you do not confirm the new configuration within 5 minutes, the last changes are not implemented. After the pression of this button you will see the following message: 11.5.2.1 DEVICE TEMPORARY IP ASSIGNMENT Take a standard USB key Inside the USB key create a new txt file - The file name has to be exactly: NetworkTEMPConfig.txt Example: 192.168.0.14/24

FIRST DEVICE START |SETUP

TIGER E5 · User Manual · ENG Edit NetworkTEMPConfig.txt and write inside the temporary IP you want set for your TIGER E5. The syntax has to be: IP/24 Insert the USB key in the USB Port of the device front panel Open your browser and insert the IP in the url address. If you plug out the IP you loose the temporary IP. (in this example we have set the 192.168.0.14 IP, but you can decide freely)

FIRST DEVICE START |SETUP

TIGER E5 · User Manual · ENG 11.5.3 NTP In Setup > NTP you have all the settings related with the Network Time Protocol. Here you can synchronize the device with different desired NTP Servers clock time to start with them the data packet exchange. GENERAL SETTINGS NTP ON: click on the checkbox to enable/disable the Sync with a desired NTP server TYME SYNCH: decide the sync interval SYNC RETRIES: decide the sync retries in case of failure LOCAL TIME ZONE: select the Local Time Zone related with the geographical device position. PRIMARY NTP SERVER IP ADDRESS / URL: type the IP/URL of the desired primary NTP server to synchronize the device clock with the server clock. NTP VERSION(AUTO, V1, V2, V3, V4): select the desired NTP version

FIRST DEVICE START |SETUP

TIGER E5 · User Manual · ENG ADDITIONAL #1 NTP SERVER IP ADDRESS / URL: type the IP/URL of the first desired additional NTP server. NTP VERSION(AUTO, V1, V2, V3, V4): select the desired NTP version ADDITIONAL #2 NTP SERVER IP ADDRESS / URL: type the IP/URL of the second desired additional NTP server. NTP VERSION(AUTO, V1, V2, V3, V4): select the desired NTP version The event section is useful to mask/unmask problems detection with the connection between the device and the NTP Servers. NTP Events Masked/Unmasked NTP Warning: the warning control records in logs section a connection problem with one or more DNS Servers. Select Mask to enable the record or Unmask to disable it Masked/Unmasked NTP Alarm: the Alarm control records in logs section a connection problem with all DNS Servers. Select Mask to enable the record or Unmask to disable for it.

FIRST DEVICE START |SETUP

TIGER E5 · User Manual · ENG 11.5.4 SNMP In Setup > SNMP you can setup all parameters related with the Simple Network Management Protocol. Here you can define parameters for different NMS (Network Management Server) for the network and trap management. SNMP Settings Snmp Agent Enabled: click on this checkbox to enable or disable the SNMP agent for the warning or alarm traps. Read Community Read Community: it is set on “public” by default. It is the Community String related to the SNMP requests from NMS to the device. If you want to protect your datas change it here and in the NMS. Write Community Public/Private: it is set on “private” by default. It is the Community String related to the SNMP device settings from NMS to the device. To have a better protection in the Write Community change the Community String here and in the NMS. HEART SIGNAL TRAP Heart Signal Trap: select between ON/OFF if you want to enable/disable the device Heartbeat signal trap. Restart SNMP Interface Restart SNMP Interface: This command restarts the SNMP interface

FIRST DEVICE START |SETUP

TIGER E5 · User Manual · ENG SNMP MIB Download MIB File: Downloads the MIB file NMS-1 SETTINGS NMS-1 IP Address / Url: type the NMS-1 IP Address / Url for SNMP traps NMS-1 Trap Port: type the NMS Trap port NMS-1 Trap Community: choose between public/private NMS-1 Trap Global Enable: choose between Enable/Disable NMS-1 Trap Type: choose between trap SNMP V1/trap SNMP V2c/info SNMP V2 NMS-1 Trap Timeout: type here the seconds for the trap timeout NMS-1 Trap Retry: type here the desired number of trap retries

FIRST DEVICE START |SETUP

TIGER E5 · User Manual · ENG NMS-2 SETTINGS NMS-2 IP Address / Url: type the NMS-2 IP Address / Url for SNMP traps NMS-2 Trap Port: type the NMS Trap port NMS-2 Trap Community: choose between public/private NMS-2 Trap Global Enable: choose between Enable/Disable NMS-2 Trap Type: choose between trap SNMP V1/trap SNMP V2c/info SNMP V2 NMS-2 Trap Timeout: type here the seconds for the trap timeout NMS-2 Trap Retry: type here the desired number of trap retries

FIRST DEVICE START |SETUP

TIGER E5 · User Manual · ENG NMS-3 SETTINGS NMS-3 IP Address / Url: type the NMS-3 IP Address / Url for SNMP traps NMS-3 Trap Port: type the NMS Trap port NMS-3 Trap Community: choose between public/private NMS-3 Trap Global Enable: choose between Enable/Disable NMS-3 Trap Type: choose between trap SNMP V1/trap SNMP V2c/info SNMP V2 NMS-3 Trap Timeout: type here the seconds for the trap timeout NMS-3 Trap Retry: type here the desired number of trap retries

FIRST DEVICE START |SETUP

TIGER E5 · User Manual · ENG NMS-4 SETTINGS NMS-4 IP Address / Url: type the NMS-4 IP Address / Url for SNMP traps NMS-4 Trap Port: type the NMS Trap port NMS-4 Trap Community: choose between public/private NMS-4 Trap Global Enable: choose between Enable/Disable NMS-4 Trap Type: choose between trap SNMP V1/trap SNMP V2c/info SNMP V2 NMS-4 Trap Timeout: type here the seconds for the trap timeout NMS-4 Trap Retry: type here the desired number of trap retries

FIRST DEVICE START |SETUP

TIGER E5 · User Manual · ENG SNMP Alarms Masked/Unmasked SNMP Warning: decide here if you want to mask/unmask the warnings related with the connectivity between the device and the NMS servers. Masked/Unmasked SNMP Alarm: decide here if you want to mask/unmask the alarms related with the connectivity between the device and the NMS servers. Traps/Notifications Masked/Unmasked SMTP Warning: Mask /Unmask the Warning trap or notifications related to the connection between the device and one or more SMTP Servers Masked/Unmasked SMTP Alarm: Mask /Unmask the Alarm trap or notifications related to the connection between the device and all set SMTP Servers

FIRST DEVICE START |SETUP

TIGER E5 · User Manual · ENG Masked/Unmasked NTP Warning: Mask /Unmask the Warning trap or notifications related to the connection between the device and one or more NTP Servers Masked/Unmasked NTP Alarm: Mask /Unmask the Alarm trap or notifications related to the connection between the device and all set NTP Servers Masked/Unmasked GPI1 Event: Mask /Unmask the Event trap or notifications related to the detection of electrical GPI1 events Masked/Unmasked GPI2 Event: Mask /Unmask the Event trap or notifications related to the detection of electrical GPI2 events Masked/Unmasked GPI3 Event: Mask /Unmask the Event trap or notifications related to the detection of electrical GPI3 events Masked/Unmasked GPI4 Event: Mask /Unmask the Event trap or notifications related to the detection of electrical GPI4 events Masked/Unmasked GPI5 Event: Mask /Unmask the Event trap or notifications related to the detection of electrical GPI5 events Masked/Unmasked GPI6 Event: Mask /Unmask the Event trap or notifications related to the detection of electrical GPI6 events Masked/Unmasked GPS Alarm: Mask /Unmask the GPS Alarm trap or notifications related to the connection between the device and the connected GPS device Masked/Unmasked Pilot Sync Alarm: Mask /Unmask the Alarm trap or notifications related to the connection between the device and the connected stereo encoder/digital pilot generator

FIRST DEVICE START |SETUP

TIGER E5 · User Manual · ENG 11.5.5 SMTP In Setup > SMTP you can setup all parameters related to the Simple Mail Transfer Protocol. Here you can define parameters for different SMTP servers for the e-mail notification on the device functioning. SMTP Settings SMTP On: Click on the checkbox to activate/deactivate the SMTP service Delivery Interval: Select the desired Delay Interval for the Email Notifications. If SMTP On is checked you will have Email Notifications every Delivery Interval. Sender E-Mail Name: Type here a standard Sender E-mail Name Sender Display Address: Type here the default Sender Display Address. Receivers will read this sender address Sender E-Mail Subject: Email Receivers will read this E-Mail Subject. SMTP Receivers Receiver #1: type the 1st target email address (optional) Receiver #2: type the 2nd target email address Receiver #3: type the 3rd target email address Receiver #4: type the 4th target email address

FIRST DEVICE START |SETUP

TIGER E5 · User Manual · ENG MAIN SMTP Server Settings Description: type here a short description for the desired main SMTP Server Server IP Address / Url: the IP Address / Url of your SMTP server domain Port: TCP port for the communication Security protocol: Network Security protocol Authorization Method: choose the desired method from the list Username: email username Password: email password

FIRST DEVICE START |SETUP

TIGER E5 · User Manual · ENG Additional SMTP Server #1 Settings Enable Server: check this box if you want to enable the first additional SMTP Server Description: type here a short description for the desired SMTP Server Server IP Address / Url: the IP Address / Url of your SMTP server domain Port: TCP port for the communication Security protocol: Network Security protocol Authorization Method: choose the desired method from the list Username: email username Password: email password

FIRST DEVICE START |SETUP

TIGER E5 · User Manual · ENG Additional SMTP Server #2 Settings Enable Server: check this box if you want to enable the second additional SMTP Server Description: type here a short description for the desired SMTP Server Server IP Addres / Url: the IP Address / url of your SMTP server domain Port: TCP port for the communication Security protocol: Network Security protocol Authorization Method: choose the desired method from the list Username: email username Password: email password SMTP Events Masked/Unmasked SMTP Warning: the warning control logs a connection problem with one or more SMTP Servers. Select Masked to enable the log or Unmasked to disable it Masked/Unmasked NTP Alarm: the Alarm control logs a connection problem with all SMTP Servers. Select Masked to enable the log or Unmasked to disable it.

FIRST DEVICE START |SETUP

TIGER E5 · User Manual · ENG 11.5.6 GPIO In Setup > GPIO you can setup all parameters related with the General Purpose Input/Output. Here you can define the behaviour of different GPI or GPO devices. GPI Logic For every following 6 GPI devices you can choose between: Positive Logic: the event is logged when the GPI circuit is closed. Negative Logic: the event is logged when the GPI circuit is opened

FIRST DEVICE START |SETUP

TIGER E5 · User Manual · ENG GPI Events Masked/Unmasked GPI1 Event: Select Masked to enable or Unmasked to disable the log of GPI1 events Masked/Unmasked GPI2 Event: Select Masked to enable or Unmasked to disable the log of GPI2 events Masked/Unmasked GPI3 Event: Select Masked to enable or Unmasked to disable the log of GPI3 events Masked/Unmasked GPI4 Event: Select Masked to enable or Unmasked to disable the log of GPI4 events Masked/Unmasked GPI5 Event: Select Masked to enable or Unmasked to disable the log of GPI5 events Masked/Unmasked GPI6 Event: Select Masked to enable or Unmasked to disable the log of GPI6 events

FIRST DEVICE START |SETUP

TIGER E5 · User Manual · ENG GPO LOGIC For every following 4 GPO devices you can choose between: Positive Logic: the generated event is the closing of the GPO circuit Negative Logic: negative logic: the generated event is the opening of the GPO circuit

FIRST DEVICE START |SETUP

TIGER E5 · User Manual · ENG In GPO Event Notifications you can decide to root to the GPO device: no Event Source(OFF), to root all Event Sources(ON), to root a selected Event Source (in example: NTP Alarm). in every GPO menu select the event source that you want to listen, as shown in the following picture: Pilot Sync Alarm: alarm starting when the frequency of the encoded RDS/RBDS signal is out of sync with an available external pilot(analogue MPX frequency / digital frequency by the SYNC/MPX inputs).

FIRST DEVICE START |SETUP

TIGER E5 · User Manual · ENG 11.5.7 GPS In Setup > GPS you can setup all parameters related to the Global Positioning System. Here you can define parameters for a desired GPS device for the satellite geolocation. General Settings Gps On: Enable/Disable the GPS device Gps Device: Name of the GPS device connected GPS Lock Status: Lock/Unlock the GPS status GPS Satellites in view: Satellites Number in view GPS Latitude: Type here the Latitude coordinate. If GPS is turned on this value is automatically inserted GPS Longitude: Type here the Longitude coordinate. If GPS is turned on this value is automatically inserted GPS Date & Time Last Value: Type here the Date and Time. If Get UTC from GPS is enabled this value is automatically inserted GPS Events Masked/Unmasked GPS Alarm: the alarm control logs a connection problem with the GPS device. Select Masked to enable the log or Unmasked to disable it

FIRST DEVICE START |SETUP

TIGER E5 · User Manual · ENG 11.5.8 SYSTEM TOOLS 11.5.8.1 UPDATES FIRMWARE UPDATES By pushing the button below you will search if there are FW update files available. If so, you can update the Firmware clicking on 'Upgrade' in the window. During this process you should not shutdown or reboot this device. SYSTEM UPGRADES By pushing the button below you will search if there are System upgrade files available. Warning: If you upgrade System clicking on 'Upgrade' in the window this device will be rebooted.

FIRST DEVICE START |SETUP

TIGER E5 · User Manual · ENG 11.5.8.2 DEVICE MANAGEMENT REBOOT DEVICE This button will cause a device reboot. 11.5.8.3 SD CARD UTILITIES SD STATUS SD Found If an external SD is found, this status will be OK, otherwise to use the tools below you need to insert (or change) a SD card in the external back slot. SD Structure The external SD card must be formatted and prepared with a particular folder tree. If this status is not OK, you need to format & prepare it using the format button below. FORMAT AND PREPARE This procedure will format the external SD card and prepares it to receive data.

FIRST DEVICE START |SETUP

TIGER E5 · User Manual · ENG CLONING TOOLS This procedure will create a clone data structure on the external SD card. This procedure will create a clone data structure from the external SD card. Important: System will be offline for a few minutes.

FIRST DEVICE START |ADMINISTRATION

TIGER E5 · User Manual · ENG ADMINISTRATION In Administration section you can read, manage all the users and you can set their access permissions to the device. These section can be managed only by the Admin users. Users List Selected user Not selected user Remove button Confirm the selected user removal Add a new User User Details (user name)

FIRST DEVICE START |ADMINISTRATION

TIGER E5 · User Manual · ENG Full Name: User Name E-Mail: user email User Class: user class, here you can decide user permissions. Discard Changes from the selected user Change the password for the selected user Save Changes for the selected user

FIRST DEVICE START |ADMINISTRATION

TIGER E5 · User Manual · ENG 11.6.1 USER CLASS – USER RIGHTS TO LOGIN THE SYSTEM Super Technician Hided user, it could not be delated or edited. The Super Technician has access to all pages, including calibration. Useful when debugging and to calibrate the machine. Full Administrator The Full Administrator manages all user profiles, accesses all pages (except the calibration). Default Administrator (Default User): The default administrator is the default user of the device, it is under the Full Administrator cathegory, but it has fixed access credentials (user: admin – pwd: admin). This user is visible only when the system has no other Full Administrators. User Administrator User Administrator. It manages the profiles of all users. Device Administrator Non-administrator user that accesses all pages (it does not accesses to administration, calibration and some of the product nameplate data). Technician Technician is the one who controls all the hardware parameters of the machine and the control of information pages. Broadcaster It has full control only on information management pages and on the audio signal. Guest/Reader Guest accesses anywhere without being able to edit any parameter.

FIRST DEVICE START |ADMINISTRATION

TIGER E5 · User Manual · ENG Below, a summary table with the list of product pages and access rights for each type of use: Legend RW: full access (read/write) R: read only user H: hided page Page Super Tech Full Admin User Admin Device Admin Technician Broadcaster Guest Home R R R R R R R General Setup RW RW R RW RW R R Network RW RW R RW RW R R NTP RW RW R RW RW R R SNMP RW RW R RW RW R R SMTP RW RW R RW RW R R GPIO RW RW R RW RW R R GPS RW RW R RW RW R R Updates RW RW R RW R R R Device Management RW RW R RW R R R SD Card Utilities RW RW R RW R R R Administration RW RW RW H H H H Logs H RW RW RW RW RW R Logs (Debug) RW H H H H H H Configuration RW RW R RW RW RW R Quick Rds Setup RW RW R RW R R R Serial Ports RW RW R RW RW R R Tcp/Ip Ports RW RW R RW RW R R UDP/SNMP Ports RW RW R RW RW R R Uecp Addressing RW RW R RW RW R R Rds Settings RW RW R RW RW R R Real Time Clock RW RW R RW RW R R Uecp Services RW RW R RW R RW R Uecp Main PS RW RW R RW R RW R Uecp Main AF RW RW R RW R RW R

FIRST DEVICE START |ADMINISTRATION

TIGER E5 · User Manual · ENG Uecp Radiotext RW RW R RW R RW R Uecp Eon PS RW RW R RW R RW R Uecp Eon AF RW RW R RW R RW R Extended Dataset RW RW R RW R RW R Extended PS Name RW RW R RW R RW R Extended Radiotext RW RW R RW R RW R Extended TA & M/S RW RW R RW R RW R Extended Pty&Ptyn RW RW R RW R RW R RDS Blocks Analysis R R R R R R R Audio Input Sources: Analogic RW RW R RW RW RW R Audio Input Sources: Digital RW RW R RW RW RW R Audio Input Sources: Multimedia RW RW R RW RW RW R Audio Input Sources: MPX Decoder RW RW R RW RW RW R Audio Input Sources: Audio Generator RW RW R RW RW RW R Audio Input Sources: Output Monitor RW RW R RW RW RW R Audio Input: Changeover RW RW R RW RW RW R Audio Input:Audio Analysis RW RW R RW RW RW R Internal MPX Encoder RW RW R RW RW RW R MPX Changeover: Delay RW RW R RW RW RW R MPX Changeover: Source A RW RW R RW RW RW R MPX Changeover: Source B RW RW R RW RW RW R MPX Outputs RW RW R RW RW RW R

FIRST DEVICE START |ADMINISTRATION

TIGER E5 · User Manual · ENG MPX Analysis RW RW R RW RW RW R Multimedia Stramer: Encoder RW RW R RW RW RW R Multimedia Stramer: Decoder RW RW R RW RW RW R Multimedia Output RW RW R RW RW RW R Calibration (and MAC Address) RW H H H H H H

FIRST DEVICE START |ADMINISTRATION

TIGER E5 · User Manual · ENG 11.6.2 ADDING A NEW USER To add a New User read the following steps: 1. Click on Add a New User button 2. Type in the following fields the new user details: User Name: New User name Full Name: New User full name E-Mail: New User email address User Class: Select here the new user class Password: New User Password Password(Confirm): Password confirmation 3. click on to discard last changes or click on to save for them.

FIRST DEVICE START |LOGS

TIGER E5 · User Manual · ENG 11.6.3 REMOVING AN EXISTING USER To remove an Existing User read the following steps: 1. Move the mouse on the desired user 2. Click on button 3. In the following mask Click on to exit from the user deletion or click on to confirm his deletion LOGS In Logs section you can read for all the device Log list. You can see four Logs Section. For every section you can , you can Logs from the device beginning, or you can . All user classes can click some of these three buttons. Logs - User Permissions: Administrator, super user, technician, broadcaster, default administrator - Logs Read&Write, Logs Debug Hided) Super Technician(Logs Hided , Logs Debug Read&Write) Guest (Logs Read&Write, Logs Debug Hided)

FIRST DEVICE START |CONFIGURATION

TIGER E5 · User Manual · ENG 11.7.1 DEBUG LOGS In this section you can read for the connection errors logs with the previously set parameters in Setup section. 11.7.2 USERS LOGS In this section you can read for the user logs changes or user logins or logouts. 11.7.3 EVENTS LOGS In this section you can read for the logs of all detected events if they are unmasked in the related section. 11.7.4 NOTIFICATIONS LOGS In this section you can read for the logs of sent notifications or alarms. CONFIGURATION Configuration Import an existing .cnf file (json format) with all RDSE3 configs Export a .cnf file (json format) with all RDSE3 configs in the desired folders

FIRST DEVICE START |RDS/RBDS

TIGER E5 · User Manual · ENG RDS/RBDS In RDS/RBDS section you can set all the parameters from RadioText, to AF, from EON to PTY/PTYN. You can also set all Extended RDS/RBDS parameters. In this section you can setup all the shown parameters. 11.9.1 QUICK RDS SETUP In this section it is possible to fill all the most important RDS/RBDS Parameters (In example PS, Radiotext..) All the parameters are explained in light-blue info boxes. ATTENTION: By pressing Start RDS Configuration you will reset the device to basic configurations. Do not press it if you do not want to loose some settings 11.9.2 UECP PORTS From this section you can set communication parameters with available remote devices. These devices must be able to send UECP packets from their serial ports.

FIRST DEVICE START |RDS/RBDS

TIGER E5 · User Manual · ENG 11.9.2.1 SERIAL PORTS Serial 1 Port Configuration Speed(UECP_7_05_100224 standard – Chapter: 3.1.59): No action, 75/…/115200 bps Communication Mode (UECP_7_05_100224 standard – Chapters: 1.3.1 / 1.3.2 / 1.3.3): Unidirectional, Bidirectional Spontaneous, Bidirectional Requested Timeout(UECP_7_05_100224 standard – Chapter: 3.1.60): No action, 1/2/3/../10 min, Inactive Serial 2 Port Configuration Speed(UECP_7_05_100224 standard – Chapter: 3.1.59): No action, 75/…/115200 bps Communication Mode (UECP_7_05_100224 standard – Chapters: 1.3.1 / 1.3.2 / 1.3.3): Unidirectional, Bidirectional Spontaneous, Bidirectional Requested Timeout(UECP_7_05_100224 standard – Chapter: 3.1.60): No action, 1/2/3/../10 min, Inactive

FIRST DEVICE START |RDS/RBDS

TIGER E5 · User Manual · ENG 11.9.2.2 TCP/IP PORTS From this section you can set communication parameters with available remote devices. These devices must be able to send UECP packets through the TCP/IP protocol. Tcp/Ip 1 Port Configuration Mode: No Action, Low Priority, Normal Priority, High Priority Communication Mode(UECP_7_05_100224 standard – Chapters: 1.3.1 / 1.3.2 / 1.3.3): Unidirectional, Bidirectional Spontaneous, Bidirectional Requested Timeout(UECP_7_05_100224 standard – Chapter: 3.1.60): No action,1/2/.../254 min, Inactive Tcp/Ip 2 Port Configuration Mode: No Action, Low Priority, Normal Priority, High Priority Communication Mode(UECP_7_05_100224 standard – Chapters: 1.3.1 / 1.3.2 / 1.3.3): Unidirectional, Bidirectional Spontaneous, Bidirectional Requested Timeout(UECP_7_05_100224 standard – Chapter: 3.1.60): No action,1/2/.../254 min, Inactive

FIRST DEVICE START |RDS/RBDS

TIGER E5 · User Manual · ENG Tcp/Ip 3 Port Configuration Mode: No Action, Low Priority, Normal Priority, High Priority Communication Mode(UECP_7_05_100224 standard – Chapters: 1.3.1 / 1.3.2 / 1.3.3): Unidirectional, Bidirectional Spontaneous, Bidirectional Requested Timeout(UECP_7_05_100224 standard – Chapter: 3.1.60): No action,1/2/.../254 min, Inactive Tcp/Ip 4 Port Configuration Mode: No Action, Low Priority, Normal Priority, High Priority Communication Mode(UECP_7_05_100224 standard – Chapters: 1.3.1 / 1.3.2 / 1.3.3): Unidirectional, Bidirectional Spontaneous, Bidirectional Requested Timeout(UECP_7_05_100224 standard – Chapter: 3.1.60): No action,1/2/.../254 min, Inactive

FIRST DEVICE START |RDS/RBDS

TIGER E5 · User Manual · ENG 11.9.2.3 UDP & SNMP PORTS From this section you can set communication parameters with available UDP remote devices. These devices must be able to send UECP packets through UDP protocol. UDP 1 Port Configuration Mode: No Action, Low Priority, Normal Priority, High Priority Timeout(UECP_7_05_100224 standard – Chapter: 3.1.60): No action,1/2/.../254 min, Inactive UDP 2 Port Configuration Mode: No Action, Low Priority, Normal Priority, High Priority Timeout(UECP_7_05_100224 standard – Chapter: 3.1.60): No action,1/2/.../254 min, Inactive

FIRST DEVICE START |RDS/RBDS

TIGER E5 · User Manual · ENG UDP 3 Port Configuration Mode: No Action, Low Priority, Normal Priority, High Priority Timeout(UECP_7_05_100224 standard – Chapter: 3.1.60): No action,1/2/.../254 min, Inactive UDP 4 Port Configuration Mode: No Action, Low Priority, Normal Priority, High Priority Timeout(UECP_7_05_100224 standard – Chapter: 3.1.60): No action,1/2/.../254 min, Inactive The next setting section rules the communication with available devices. These devices must be able to send UECP packets in SNMP protocol.

FIRST DEVICE START |RDS/RBDS

TIGER E5 · User Manual · ENG SNMP Port Configuration Mode: No Action, Low Priority, Normal Priority, High Priority Timeout(UECP_7_05_100224 standard – Chapter: 3.1.60): No action,1/2/.../254 min, Inactive 11.9.3 BASIC SETTINGS

FIRST DEVICE START |RDS/RBDS

TIGER E5 · User Manual · ENG 11.9.3.1 UECP ADDRESSING The recipient encoder, getting UECP data frames from remote devices, must be identifiable by a unique address: Site (Zone) + Encoder ID. The remote devices will send UECP data frames to recipients through this addressing data couple. In example a UECP data frame could be sent to all RDS devices of a desired Site or to the same Encoder ID of all Sites. This section is used to set the individual device UECP address. In Individual Address set RDS site number and encoder number. Individual Address Site(Zone): assign to your device a desired site number Encoder: assign to your device a desired encoder ID number Uecp Address Here you can have all the Uecp Addresses list. Site Addresses: the range of possible values is 1 to 1023 Encoder Addresses: the range of possible values is 1 to 63

FIRST DEVICE START |RDS/RBDS

TIGER E5 · User Manual · ENG 11.9.3.2 RDS SETTINGS Rds General Settings Rds On: In the device Enable/Disable the RDS encoding Rds Global Extended Mode: Enable/Disable the Extended Mode Rds Synchronism (Pilot Synch): Internal, Auto Sync In (External & Digital), Auto Mpx In(External & Analogue) PS Char Table Select: we suggest you to leave this parameter in No Control Chars Active Dataset Selection On Air Active Dataset: select the Dta Set number that you want to air.

FIRST DEVICE START |RDS/RBDS

TIGER E5 · User Manual · ENG Rds Levels Current Level and Phase Reference Table Index: in the next field, enter the index number of the table row The related signal Level and signal Phase couple will be aired Level and Phase Reference Table: available, choosable and editable Levels(mVpp: millivolt peak-to-peak) and related Phases(Deg: Degrees). The following two parameter groups manage the special transitions of 15B group and 14B group in the standard RDS group sequence at the TA/EON TA - ON/OFF. TA Control (15B) This control force the transition of the 15B group in the standard RDS group sequence in relation with the activation/deactivation of the TA. Minimum Group Spacing: number of groups of the standard RDS sequence, between two recurrences of the 15B groups will be inserted and transmitted. ON Transition 15B(fast signal switching) Groups: only when TA is turned-ON, this parameter decides the number of 15B groups transmitted in a single recurrence. OFF Transition 15B Groups: only when TA is turned-OFF, this parameter decides the number of 15B groups transmitted in a single recurrence

FIRST DEVICE START |RDS/RBDS

TIGER E5 · User Manual · ENG EON TA Control (14B) This control force the transition of the 14B group in the standard RDS group sequence in relation with the activation/deactivation of the EON TA. Minimum Group Spacing: number of groups of the standard RDS sequence, between two recurrences of the 14B groups will be inserted and transmitted. ON Transition 14B(fast signal switching) Groups: only when EON TA is turned-ON, this parameter decides the number of 14B groups transmitted in a single recurrence. OFF Transition 14B Groups: only when EON TA is turned-OFF, this parameter decides the number of 14B groups transmitted in a single Recurrence File Name: in this field type the file name. The RDS will search in the previously set SMB/SAMBA IP/FOLDER for song and author informations. Format: Choose between DjPro V.1.0, DjPro V.2.0, Dalet Simple, MB Studio. Status: in this field you can see if the file is found or not

FIRST DEVICE START |RDS/RBDS

TIGER E5 · User Manual · ENG RDS Events Masked/Unmasked Pilot Sync Alarm: Mask/Unmask the alarm of the synchronization between a Pilot frequency and the encoder. Masked/Unmasked Smb/Samba Share Rds Alarm: Mask/Unmask the alarm of the connection with the communication folder with your playout. 11.9.3.3 REAL TIME CLOCK RTC Settings CT On/Off: enable/disable the transmission of RDS Time clock. Local Time Offset: Select here the desired Local Time Offset. Real Time Clock Correction (ms): to avoid delays related to the signal transmission-reception, insert here a clock correction time(ms).

FIRST DEVICE START |RDS/RBDS

TIGER E5 · User Manual · ENG 11.9.4 STANDARD MODE 11.9.4.1 UECP SERVICES Dataset General Settings Editing Dataset Index: Select here the desired Index to start the related Dataset editing. PSN List Reference: in reference you can read all the available reference names PS-Number: PS-Number of the related reference ENABLED: (-E- : PSN enabled) (--- : PSN disabled)

FIRST DEVICE START |RDS/RBDS

TIGER E5 · User Manual · ENG PSN List Enable is an example of Enabled EON. If the EON is enabled you can see in the bottom section. To disable it click on the related is an example of Disabled EON. To enable it click on it. Group List In the following mask you can decide the Group List and the group sequence order. to add the group at the end of the group sequence In the bottom section you see the list of group sequence represents a present group inside the group sequence By clicking on you move it in the previous sequence position By clicking on you move it in the following order position By clicking on you erase it from the sent RDS/RBDS groups.

FIRST DEVICE START |RDS/RBDS

TIGER E5 · User Manual · ENG By clicking on you can open the following top descripting table: Group 1A Variant Sequence (SLC – Slow Labelling Codes) In the following mask you can decide the Group 1A Variant Sequence and his Slow Labelling Codes sequence order. to add the SLC at the end of the sequence In the bottom section you see the list of SLC sequence represents a present SLC inside the sequence By clicking on you move it in the previous sequence position By clicking on you move it in the following order position By clicking on you erase it from the transmitted SLCs.

FIRST DEVICE START |RDS/RBDS

TIGER E5 · User Manual · ENG By clicking on you can open the following top descripting table: Group 14A Variant Sequence (EON – Enhanced Other Networks information) In the following mask you can decide the Group 14A Variant Sequence and his Codes sequence order. to add the Code at the end of the sequence In the bottom section you see the list of Codes sequence represents a present code inside the sequence By clicking on you move it in the previous sequence position By clicking on you move it in the following order position By clicking on you erase it from the transmitted codes list.

FIRST DEVICE START |RDS/RBDS

TIGER E5 · User Manual · ENG By clicking on you can open the following top descripting table: 11.9.4.2 UECP MAIN PS This section is useful to define all UECP Main PS parameters Main Network Program Service Editing Dataset Index: decide which Main PS you want to edit, select the related DSN (Dataset Number) Editing Program Service: You will see this parameter also in UECP Eon PS. Here the parameters is not selectable because this is the MAIN Program.

FIRST DEVICE START |RDS/RBDS

TIGER E5 · User Manual · ENG Basic Settings PI(Program Identification): type the PI Code PS(Program Station): type the Program Station Name TP(Traffic Program): On/Off TA(Traffic Announcement): On/Off PTY: selectable value between: Pop Music, Rock Music, Culture, Science… PTYN: type a desired description for the program PIN Day: if you want to schedule a special PTY insert here the month day. From 00 to 31. PIN Hour: If you want to schedule a special PTY insert here the desired hour (HH). From 00 to 23. PIN Minute: If you want to schedule a special PTY insert here the desired minute (MM). From 00 to 59. Music/Speech: select here if you have Music program or a Speech program Decoder Information: select the audio decoder information

FIRST DEVICE START |RDS/RBDS

TIGER E5 · User Manual · ENG Linkage Linkage information provides the means by which several programme services, each characterised by its own PI code, may be treated by a receiver as a single service during times a common programme is carried. During such times each programme service retains its unique identity, i.e. the programme service must keep its designated PI code and its AF (Alternative Frequency) list(s), but may change programme related features such as PS, PTY, RT, TP and TA to reflect the common programme; Linkage information is conveyed in the following four data elements: LA(linkage actuator) EG(extended generic index) ILS (international linkage standard) LSN (linkage set number) Slow Labelling Codes The RDS specification contains some additional slow labelling codes that are used to support various features. These are specified to be carried in the type 1A group. In this section you can set SLC values. SLC 0 (ECC) SLC 1 (TMC) SLC 2 (Paging) SLC 3 (Language) SLC 4 (not assigned) SLC 5 (not assigned) SLC 6 (Broadcaster use) SLC 7 (EWS)

FIRST DEVICE START |RDS/RBDS

TIGER E5 · User Manual · ENG RBDS PI CALCULATOR (only if you are working on US soil) CALL Letters: write the desired CALL Letters in this field, then click Convert. You will read the converted hexadecimal value in PI Code (Ex) PI Code (Hex): write the desired hexadecimal PI Code in this field. Then click Convert. You will read the converted value in CALL Letters. 11.9.4.3 UECP MAIN AF Main Network Editing Controls Editing Dataset Index: decide which Main AF List (alternative frequencies) you want to edit, select the related DSN (Dataset Number) Editing Program Service: You will see this parameter also in UECP Eon AF. Here the parameter is not selectable because this is AF of the MAIN Program Service.

FIRST DEVICE START |RDS/RBDS

TIGER E5 · User Manual · ENG Alternative Frequencies In the following list you can read AF (alternative frequencies) list of desired Tuned frequencies. You see the list of Tuned frequencies with their own AF list. Black AF are universal. Blue AF are regional. click on to add a new row with AF list or click on an existing row to edit it. The following mask will be enabled: Method: decide between A/B. The B method allows you to specify also the regionality of the AF Tuned Freq: here the Main Tuned Freq. AF List: in this list you see different alternative frequencies separated by a comma (,) and a space. If you want to specify that 90.2 frequency is regional. Type 90.2r. Add: click on add to confirm parameters and to add them in rows. Remove: click on a row that you want to delete and click on remove Update: select a row that you want to edit, change parameters and click Update to save changes.

FIRST DEVICE START |RDS/RBDS

TIGER E5 · User Manual · ENG 11.9.4.4 UECP RADIOTEXT Main Network Editing Controls Editing Dataset Index: decide which RadioText you want to edit, select the related DSN (Dataset Number) Editing Program Service: Here the Program Service is not selectable because this is AF of the MAIN Program. Radiotext Reps: number of radiotext message repetitions A/B Flag: The A/B flag is an important part of proper radiotext transmission. This flag is used to signal the receiver when a new text message is transmitted. When the receiver detects a change in the A/B flag state, the radiotext receiver buffer will be cleared, preventing the possibility of a mixture of old and new text messages being displayed on the receiver. In conclusion, the A/B flag should be enabled when multiple RT messages are scheduled, while it can be disabled in the event of a fixed RT broadcasting. RadioText: RadioText message Add: after the new message creation click on send to start the RadioText transmission. Remove: deletes the selected RadioText message Update: , by selecting an existing RadioText row you can change it. To save new settings click on this button.

FIRST DEVICE START |RDS/RBDS

TIGER E5 · User Manual · ENG 11.9.4.5 UECP EON PS EON Program Service Editing Dataset Index: decide which Eon PS(Program Service) you want to edit, select the related DSN (Dataset Number) Editing Program Service: You will see this parameters also in UECP Eon AF. you can select between 10 different EON Program Services. EON Basic Settings PI(Program Identification): type the PI Code PS(Program Station): type the Program Station Name TP(Traffic Program): On/Off TA(Traffic Announcement): On/Off PTY: selectable value between: Pop Music, Rock Music, Culture, Science… PTYN: type a desired description for the program PIN Day: if you want to schedule a special PTY insert here the month day. From 01 to 31. PIN Hour: If you want to schedule a special PTY insert here the desired hour (HH). Possible. From 00 to 23. PIN Minute: If you want to schedule a special PTY insert here the desired minute (MM). From 00 to 59. Music/Speech: select here if you have Music program or a Speech program Decoder Information: select the audio decoder information

FIRST DEVICE START |RDS/RBDS

TIGER E5 · User Manual · ENG Eon Linkage Linkage information provides the means by which several programme services, each characterised by its own PI code, may be treated by a receiver as a single service during times a common programme is carried. During such times each programme service retains its unique identity, i.e. the programme service must keep its designated PI code and its AF (Alternative Frequency) list(s), but may change programme related features such as PS, PTY, RT, TP and TA to reflect the common programme; Linkage information is conveyed in the following four data elements: LA(linkage actuator) EG(extended generic index) ILS (international linkage standard) LSN (linkage set number) 11.9.4.6 UECP EON AF Eon Editing Controls Editing Dataset Index: decide which EON AF (alternative frequencies) you want to edit, select the related DSN (Dataset Number) Editing Program Service: You will see this parameter also in UECP Main AF, you can select between 10 different EON Program Services.