IntelliSense FG-1015 Installation Instructions
| Brand: | IntelliSense |
| Category: | Security System |
| Model: | FG-1015 (Installation Instructions) |
| File Type: | |
| File Size: | — |
| Pages: | 2 |
Text of IntelliSense FG-1015 Installation Instructions
IntelliSense FG-1015 with Digital Signal Processing
(DSP)
•
Continuous self-test
•
No adjustments
•
No minimum range
•
Remote Test Mode activation
with FG-701 simulator
•
8 - 14 VDC operation
TM
INSTALLATION
INSTRUCTIONS
Model FG-1015
�����������
��������
•
PCB and housing designed
to protect against ESD and
mechanical damage
•
Watchdog for micro-
controller
•
Green event LED lights
Normal, no event
OFF
OFF
Normal, event detected
Flicker
OFF
Normal, break detected
OFF
ON
Power-up self-test
ON, one second
ON, one second
Trouble detected
Flash ON/OFF
Flash OFF/ON
Test mode, no alarm
Flash once per second
OFF
Test mode, event detected
Flicker
OFF
Test mode, alarm
Flash once per second
ON
SPECIFICATIONS
Alarm Relay:
Form A
125 mA maximum
25 VDC maximum
Alarm Duration:
5 seconds
Tamper Switch:
Cover tamper
25 m