Rayburn XT Installation Instructions Manual
Text of Rayburn XT Installation Instructions Manual
PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLING THIS APPLIANCE
For use in GB and IE
Installation
Instructions
XT - Gas (GPF)
10/13 EINS 514103
[email protected]
DESN 514112 B
Remember, when replacing a part on this appliance, use only spare parts that you can be assured conform to the safety
and performance specification that we require. Do not use reconditioned or copy parts that have not been clearly
authorised by AGA.
HEALTH & SAFETY
3
TECHNICAL DATA
4
SITE REQUIREMENTS
INTRODUCTION
5
IMPORTANT
5
REGULATIONS
5
GAS SUPPLY
5
LOCATION
5
ELECTRICAL SUPPLY
6
FLUE SYSTEM
7-9
FLUE TERMINAL LOCATION
10
INSTALLATION
11
PCB CONNECTIONS
12
INSTALLATION REQUIREMENTS
CLEARANCES
13
PRELIMINARY INSTALLATION
13
SITE LOCATION
14
SETTING COMBUSTION
15
INSTALLATION INSTRUCTIONS
BURNER ACCESS
16
ELECTRICAL CONNECTION
16
BOILER CONTROL (BURNERTECH
As responsible manufacturers we take care to make sure that our products are designed and
constructed to meet the required safety standards when properly installed and used.
IMPORTANT NOTICE: PLEASE READ THE ACCOMPANYING WARRANTY.
Any alteration that is not approved by AGA could invalidate the approval of the appliance,
operation of the warranty and could affect your statutory rights.
Health & Safety
This appliance may contain some of t
Natural Gas (G20) I2H
Gas Inlet
R 1/2 (1/2” BSP TAPER)
Electrical Supply
230V ~ 50Hz 3 amp Fused
Flue Pipe Diameter
54mm St/St
Flue Terminal Size:
Width
500mm
Height
210mm
Depth
180mm
Burner Inlet Pressure
20mbar
CO
0 - 50 ppm
CO2%
8.2% - 9.9%
Heat Input
14.6 kW
Unpacked Appliance Weight - 350 Kg
Fuel -
Propane (G31) I3P
Gas Inlet
R 1/2 (1/2” BSP TAPER)
Electrical Supply
230V ~ 50Hz 3 amp Fused
Flue Pipe Diameter
54mm St/St
Flue Terminal Size:
W
The Rayburn is a floor standing cooker, fired by a gas
burner.
The burner fitted to this appliance has been designed
and constructed exclusively for use with the Rayburn
XT Cooker and MUST not be used on any other
appliances or any other uses.
In the interests of safety all gas appliances should be
installed by competent persons in accordance with the
regulations in force.
Installation Pipes
Pipework from the meter to the appliance must be of
adequate siz
Wiring external to the appliance must be installed in
accordance with current National Wiring Regulations and
and local regulations which apply. The appliance is
supplied for 230 Volt ~ 50 Hz and a fuse rating of 3 amps.
The method of connection to the mains supply should
facilitate complete electrical isolation of the appliance, by
the use of a fused double pole switch having a contact
separation of at least 3mm serving only the appliance.
The point of co
The flue can be to the left or right of the appliance. The
cooker is supplied with the flue pipe to the left, this can be
adjusted to suit the installation.
FLUE DIRECTION - EXIT TO THE LEFT
1. Remove lower back panel (7 screws).
2. Unscrew the two fixing brackets and remove. (See
Fig. 2).
3. Slacken the jubilee clip, fixing flexible pipe to
horizontal pipe (A). (See Fig. 2).
4. If the flue pipe is to be routed as per factory set,
remove
FLUE DIRECTION - EXIT TO THE RIGHT
Follow previous instructions in FLUE SYSTEM (Page 7),
Steps 1 to 3.
4. Reposition the flexible tube from the oven vent down
the back of the oven.
5. Smear sealant on the end of the manifold and replace
the bend.
6. Smear sealant on the first end of pipe ‘A’ and the
surface of the 28mm branch (towards the bend). Slide
the flexible pipe completely over the branch (pipe
should point towards burner chamb