PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLING THIS APPLIANCE

For use in GB and IE Installation Instructions XT - Gas (GPF) 10/13 EINS 514103 [email protected] DESN 514112 B Remember, when replacing a part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification that we require. Do not use reconditioned or copy parts that have not been clearly authorised by AGA.

HEALTH & SAFETY

3 TECHNICAL DATA 4 SITE REQUIREMENTS INTRODUCTION 5 IMPORTANT 5 REGULATIONS 5 GAS SUPPLY 5 LOCATION 5 ELECTRICAL SUPPLY 6 FLUE SYSTEM 7-9 FLUE TERMINAL LOCATION 10 INSTALLATION 11 PCB CONNECTIONS 12 INSTALLATION REQUIREMENTS CLEARANCES 13 PRELIMINARY INSTALLATION 13 SITE LOCATION 14 SETTING COMBUSTION 15 INSTALLATION INSTRUCTIONS BURNER ACCESS 16 ELECTRICAL CONNECTION 16 BOILER CONTROL (BURNERTECH

As responsible manufacturers we take care to make sure that our products are designed and

constructed to meet the required safety standards when properly installed and used. IMPORTANT NOTICE: PLEASE READ THE ACCOMPANYING WARRANTY. Any alteration that is not approved by AGA could invalidate the approval of the appliance, operation of the warranty and could affect your statutory rights. Health & Safety This appliance may contain some of t

Natural Gas (G20) I2H

Gas Inlet R 1/2 (1/2” BSP TAPER) Electrical Supply 230V ~ 50Hz 3 amp Fused Flue Pipe Diameter 54mm St/St Flue Terminal Size: Width 500mm Height 210mm Depth 180mm Burner Inlet Pressure 20mbar CO 0 - 50 ppm CO2% 8.2% - 9.9% Heat Input 14.6 kW Unpacked Appliance Weight - 350 Kg Fuel - Propane (G31) I3P Gas Inlet R 1/2 (1/2” BSP TAPER) Electrical Supply 230V ~ 50Hz 3 amp Fused Flue Pipe Diameter 54mm St/St Flue Terminal Size: W

The Rayburn is a floor standing cooker, fired by a gas

burner. The burner fitted to this appliance has been designed and constructed exclusively for use with the Rayburn XT Cooker and MUST not be used on any other appliances or any other uses. In the interests of safety all gas appliances should be installed by competent persons in accordance with the regulations in force. Installation Pipes Pipework from the meter to the appliance must be of adequate siz

Wiring external to the appliance must be installed in

accordance with current National Wiring Regulations and and local regulations which apply. The appliance is supplied for 230 Volt ~ 50 Hz and a fuse rating of 3 amps. The method of connection to the mains supply should facilitate complete electrical isolation of the appliance, by the use of a fused double pole switch having a contact separation of at least 3mm serving only the appliance. The point of co

The flue can be to the left or right of the appliance. The

cooker is supplied with the flue pipe to the left, this can be adjusted to suit the installation. FLUE DIRECTION - EXIT TO THE LEFT 1. Remove lower back panel (7 screws). 2. Unscrew the two fixing brackets and remove. (See Fig. 2). 3. Slacken the jubilee clip, fixing flexible pipe to horizontal pipe (A). (See Fig. 2). 4. If the flue pipe is to be routed as per factory set, remove

FLUE DIRECTION - EXIT TO THE RIGHT

Follow previous instructions in FLUE SYSTEM (Page 7), Steps 1 to 3. 4. Reposition the flexible tube from the oven vent down the back of the oven. 5. Smear sealant on the end of the manifold and replace the bend. 6. Smear sealant on the first end of pipe ‘A’ and the surface of the 28mm branch (towards the bend). Slide the flexible pipe completely over the branch (pipe should point towards burner chamb