Vega VEGABAR 66 Operating Instructions Manual

File Specifications

Brand: Vega
Category: Transmitter
Model: VEGABAR 66 (Operating Instructions Manual), prw9ne4SBEtsI
File Type: PDF
File Size: —
Pages: 76 pages

Download Document

Get a high-quality, printable PDF version of this manual for offline use.

Download PDF Manual (76 pages)

⚠️ Download Safety: This PDF is completely safe to download (last scan date: 04/08/2026).

Read Online

Read the Vega VEGABAR 66 Operating Instructions Manual online using the built-in PDF viewer.

Key Pages of Document

Submersible pressure transmitter with

CERTEC® measuring cell VEGABAR 66 Foundation Fieldbus Document ID: 36740 ...

VEGABAR 66 • Foundation Fieldbus

36740-EN-141001 Contents 1 About this document 1.1 Function ........................................................................................................................... 4 1.2 Target group ..................................................................................................................... 4 1.3 Symbols used........................................................................... ...

VEGABAR 66 • Foundation Fieldbus

36740-EN-141001 7.1 Connect the PC .............................................................................................................. 44 7.2 Parameter adjustment with PACTware ............................................................................ 45 7.3 Parameter adjustment with AMS™................................................................................. 45 7.4 Saving the parameter ...

1 About this document

VEGABAR 66 • Foundation Fieldbus 36740-EN-141001 1 About this document 1.1 Function This operating instructions manual provides all the information you need for mounting, connection and setup as well as important instruc- tions�for�maintenance�and�fault�rectification.�Please�read�this�informa- tion before putting the instrument into operation and keep this manual accessible in the immediate vicinity of the device ...

2 For your safety

VEGABAR 66 • Foundation Fieldbus 36740-EN-141001 2 For your safety 2.1 Authorised personnel All operations described in this operating instructions manual must be carried out only by trained specialist personnel authorised by the plant operator. During work on and with the device the required personal protective equipment must always be worn. 2.2 Appropriate use Model VEGABAR 66 is a pressure transmitter for level and gauge measuremen ...

2 For your safety

VEGABAR 66 • Foundation Fieldbus 36740-EN-141001 2.5 Safety label on the instrument The safety approval markings and safety tips on the device must be observed. 2.6 CE conformity This�device�fulfills�the�legal�requirements�of�the�applicable�EC�guide- lines.�By�attaching�the�CE�mark,�VEGA�provides�a�confirmation�of� successful�testing.�You�can�find�the�CE�conformity�declaration� ...

3 Product description

VEGABAR 66 • Foundation Fieldbus 36740-EN-141001 3 Product description 3.1� Configuration The scope of delivery encompasses: • VEGABAR 66 pressure transmitter with suspension cable • Straining�clamp�(optionally�available�with�screwed�fitting) • External electronics • or VEGABAR 66 pressure transmitter with connection tube • Documentation – this operating instructions manual – Test�certificate�for� ...

3 Product description

VEGABAR 66 • Foundation Fieldbus 36740-EN-141001 1 2 3 4 4 5 6 Fig. 1: Example of a VEGABAR 66 with suspension cable (left) and connection tube (right) 1 Housing with integrated electronics 2 Suspension cable 3 Connection tube 4 Threaded fitting 5 Transmitter 6 Protective cap The�type�label�contains�the�most�important�data�for�identification�and� use of the instrument: Type label ...

3 Product description

VEGABAR 66 • Foundation Fieldbus 36740-EN-141001 2 1 13 10 5 4 3 6 7 8 9 11 12 14 Fig. 2: Layout of the type label (example) 1 Instrument type 2 Product code 3 Approvals 4 Electronics 5 Protection rating 6 Measuring range 7 Process and ambient temperature, process pressure 8 Material, wetted parts 9 Hardware and software version 10 Order number 11 Serial number of the instrument 12 ID numbers, instrument documentation With the ser ...

3 Product description

VEGABAR 66 • Foundation Fieldbus 36740-EN-141001 Instruments�with�hygienic�fitting�are�equipped�with�a�gap-free�form� seal. Power is supplied via the H1 Fieldbus. A two-wire cable according to Fieldbus�specification�serves�as�carrier�of�both�power�and�digital�data� for multiple sensors. This cable can be operated in two versions: • via an H1 interface card in the control system and addi ...

3 Product description

VEGABAR 66 • Foundation Fieldbus 36740-EN-141001 The delivery must be checked for completeness and possible transit damage immediately at receipt. Ascertained transit damage or con- cealed defects must be appropriately dealt with. Up�to�the�time�of�installation,�the�packages�must�be�left�closed�and� stored according to the orientation and storage markings on the outside. Unless�otherwise�indicated,� ...

3 Product description

VEGABAR 66 • Foundation Fieldbus 36740-EN-141001 You�can�find�additional�information�in�the�operating�instructions� "Mounting accessory pressure"�(Document-ID�43478). The protective cover protects the sensor housing against soiling and intense heat from solar radiation. You�will�find�additional�information�in�the�supplementary�instructions� manual�"Protective cover"�(Document-ID�34296 ...

VEGABAR 66 • Foundation Fieldbus

36740-EN-141001 4 Mounting 4.1 General instructions Make sure that all parts of the instrument coming in direct contact with the process, especially the sensor element, process seal and process�fitting,�are�suitable�for�the�existing�process�conditions,�such� as process pressure, process temperature as well as the chemical properties of the medium. You�can�find�the�specifications� ...

VEGABAR 66 • Foundation Fieldbus

36740-EN-141001 2 1 2 1 2 1 1 2 Fig. 4: Position of the filter element 1 Filter element 2 Blind plug Caution: Due�to�the�filter�effect,�the�pressure�compensation�is�time�delayed.� When opening/closing the housing cover quickly, the measured value can change for a period of approx. 5 s by up to 15 mbar. Information: Make�sure�that�the�filter�element�is�always�free�of� ...

VEGABAR 66 • Foundation Fieldbus

36740-EN-141001 Fig. 5: Mounting example: Version with connection tube in an open vessel Fig. 6: Mounting example: Version with suspension cable in a pump shaft ...

VEGABAR 66 • Foundation Fieldbus

36740-EN-141001 4.3 Mounting steps with straining clamp 2 3 1 Fig. 7: Straining clamp 1 Suspension cable 2 Suspension opening 3 Clamping jaws Mount VEGABAR 66 with straining clamp as follows: 1. Hang the straining clamp on a suitable wall hook 2. Lower VEGABAR 66 to the requested height 3. Slide the clamping jaws upward and push the suspension cable between them 4. Hold the suspension cable, push the clampin ...

VEGABAR 66 • Foundation Fieldbus

36740-EN-141001 4.4 Mounting steps with screwed connection 1 2 3 4 5 6 Fig. 8: Threaded fitting 1 Suspension cable 2 Sealing screw 3 Cone bushing 4 Seal cone 5 Threaded fitting 6 Seal Mount VEGABAR 66 with screwed connection as follows: 1. Weld the welded socket into the vessel top 2. Lower VEGABAR 66 to the requested height by means on the welded socket G1½ or 1½ NPT on the vessel side 3. Shift the suspe ...

VEGABAR 66 • Foundation Fieldbus

36740-EN-141001 4.5� Mounting�steps�with�lock�fitting 1 3 2 4 5 Fig. 9: Lock fitting 1 Upper hexagon 2 Fixing screw 3 Washer disk 4 Lower hexagon 5 Fixing screw Mount�VEGABAR�66�with�lock�fitting�as�follows: 1. Weld the welded socket G1½ or 1½ NPT to the vessel top 2. Lower VEGABAR 66 through the welded socket. 3.� Turn�the�lock�fitting�on�the�lower�hexagon�into� ...

VEGABAR 66 • Foundation Fieldbus

36740-EN-141001 4.6 Mounting steps with housing and thread Fig. 10: Housing and thread 1 Housing 2 Seal 3 Thread Mount VEGABAR 66 with housing and thread in the following way: 1. Weld the welded socket G1½ or 1½ NPT to the vessel top 2. Insert the transmitter with connection tube or suspension cable into the opening 3. Turn the thread with seal into the socket and tighten with SW 461) Warning: The housing ...

VEGABAR 66 • Foundation Fieldbus

36740-EN-141001 90 mm (3.54") R 3,5 mm (0.14") 3mm (0.12") 70 mm (2.76") 8 mm (0.32") 93 mm (3.66") 110 mm (4.33") Fig. 11: Drilling template - wall mounting plate Tip: Mount the wall mounting plate so that the cable entry of the socket housing points downward. The socket housing can be displaced by 180° to the wall mounting plate. Warning: The four screws of the socket housing must only be hand screwed. A ...