HP 5550C - ScanJet - Flatbed Scanner Manual
Text of the manual
Before proceeding, read these instructions all the way through. Then return here and follow the steps in
order.
This module is organized into the following sections:
•
preparation
•
disassembly
•
cleaning
•
reassembly
preparation
Tools needed:
•
flat-head screwdriver
•
phillips screwdriver
Supplies needed:
•
Glass cleaner
•
lint-free cloths
remove the scanner lid
After steps 1 and 2 have been completed
and the scanner has cooled for 15 minutes,
you can remove the lid as shown.
3 Open the lid and lift it straight up.
Scanner lid being removed
4 Set the lid aside.
Clean top of the scanner
Clean the outside of the scanner prior to disassembly to prevent contamination of internal
parts.
Use only glass cleaner. Avoid abrasives, acetone, benzene, and carbon tetrachloride, all of
which can damage the scanner glass. Avoid isopropyl alcohol because it can leave streaks on the glass.
Do not spray the glass cleaner directly on
Unlatch the top cover
Begin disassembly only after completing steps 1 through 6
You are about to expose the interior of the scanner to the dust of the outside environment. the
scanner is very sensitive to dust; any dust particles that get into the carriage head can cause streaks in the
scanned image. Minimize the time that the top cover is off by having all
9 Insert a flat-head screwdriver into the slot
on the back of the scanner. The slot is located
above the ADF port between the top cover and
the base. Pry the top cover up with a
screwdriver.
flat-head screwdriver being inserted between base
and top cover
remove the top cover
After unlatching the top cover, you are ready to remove it.
top cover being lift
Dust will immediately begin accumulating in your scanner now that the top cover is off.
Minimize the time the scanner base is exposed. Read all directions and have the necessary tools ready
before removing the top cover. While the top cover is off do not leave the scanner unattended.
Static discharge from your fingers, hand, or tools will damage the circuit
re-mount the top cover to the scanner
When you have finished cleaning the underside of the glass, reassemble the top cover.
12 Hold the top cover directly above the scanner and lower it into position as shown.
top cover being lowered onto base
13 snap the back of the scanner together
bus squeezing the top cover and the base
together at the A
14 Holding the top and bottom covers
together, turn the scanner upside down on a
clean surface.
insert the screws
15 Re-insert and tighten the four screws
with a Phillips screwdriver.
Step #7 Insert the screws
location of screws
16 Turn the unit over so that the glass side
is facing up.
insert the scanner lid
you can now re-insert the scanner lid,