Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification. All Dimension are in mm 1 SG Gas Burner into a Warmington SI Wood Open Fire Installation Guide Only SG 700-780-900-1100 Burner Only Traditional Grate & Burner Pure Grate & Burner Classic Grate Warmington SG Gas Burner. Warmington SI Open Wood Firebox. The fireplace is constructed and tested to comply with NZS ...

14 June 2016

Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification. All Dimension are in mm 2 POINTS TO CONSIDER PRIOR TO INSTALLATION INSTALLATION ORDER OF OPERATIONS Location of the Fire. Open Fires are better located at one end of a room or area, as they project the heat away from their opening . Venting to the Cavity. This air is to allow the Cavity ...

14 June 2016

Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification. All Dimension are in mm 3 Burner SG 700 SG 780 SG 900 SG 1100 Burner Width A 674 754 874 1074 Burner Height B 205 205 205 205 Burner Depth C 272 272 272 272 Flue Diameter Min J 200 200 250 250 Flue CSA mm K 31 416 31 416 49 087 49 087 WARMINGTON BURNERS NOTE: IMPORTANT INFORMATION FROM THE STANDARD Installati ...

14 June 2016

Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification. All Dimension are in mm 4 HEARTH CLEARANCES Note: For Combustible Floors Minimum Hearth of 300mm (A) must be maintained at any given height. * Inlet Pressure not to exceed 4.0KPa GAS SPECIFICATIONS Tested to current gas standards NOTE : All Test Pressures are tested by a Independent Test Lab ...

14 June 2016

Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification. All Dimension are in mm 5 SG Range: Gas Convection Fireplaces FLUED GAS APPLIANCES All Gas Fires requiring Warmington Flue Systems shall be Installed to the requirements of the current standards and shall be appropriately designed and constructed to permit safe and effective use. This Appliance must be flued ...

14 June 2016

Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification. All Dimension are in mm 6 Total Coals Top Bottom Top Bottom Model Total SG 700 5 6 2 2 22 6 8 2 2 SG 780 28 SG 900 9 10 2 2 38 SG 1100 10 11 2 2 42 Number of Coals per Row Number of Rows Gloves should be worn when handling Ceramic Fibre Coals & Logs: care needs to be taken when handling Coals & Logs, Due to t ...

14 June 2016

Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification. All Dimension are in mm 7 Your Fire must be Installed and Tested by a suitably qualified Gasfitter prior to use. To light : Lower the control-cover by pulling it outwards. Depress the Ignition Switch and hold in the 'PILOT' position for 3-5 seconds. (This may take some time for the Gas to come through to the ...

14 June 2016

Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification. All Dimension are in mm 8 Note: When the Base screw is removed, gas will leak from the out let, ensure that the pilot is not adjusted or the screw is removed when the fire is burning.  Adjustment of Pilot - 3 Flame: Unscrew Base Screw as shown in Diagram 2.  Insert a Screw Driver as shown in Diagram 3 ...

14 June 2016

Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification. All Dimension are in mm 9 Open windows and doors Do not light any gas appliance Do not use any electrical appliance or switches Do not use the telephone in your home Leave the building; shut off the domestic gas supply valve (beside your meter) Call your gas supplier/gas fitter or the Fire Service for further ...

14 June 2016

Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification. All Dimension are in mm 10 PROCEDURE FOR THE TEST AND COMISSIONING OF YOUR DECORATIVE FIRE. Ensure Gas Supply and the Power Supply (caution 240V) to the Unit.  Refer to Data Plate on this Specification for settings. The Data Plate is attached to the under carriage of the Burner.  Remove Front Grate ens ...

14 June 2016

Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification. All Dimension are in mm 11 GENERAL NOTES NOTES:  These installation and operating instructions should be kept in a safe place. Should you require another copy, download from the Warmington website www.warmington.co.nz  This appliance must be installed in accordance with the manufacturer’s written ins ...