Sungrow SH3K6 Quick User Manual

File Specifications

Brand: Sungrow
Category: Inverter
Model: SH3K6 (Quick User Manual), prLXDzMeFIhTg
File Type: PDF
File Size: —
Pages: 61 pages

Download Document

Get a high-quality, printable PDF version of this manual for offline use.

Download PDF Manual (61 pages)

⚠️ Download Safety: This PDF is completely safe to download (last scan date: 03/04/2026).

Read Online

Read the Sungrow SH3K6 Quick User Manual online using the built-in PDF viewer.

Key Pages of Document

Quick User Manual

SH3K6 / SH4K6 Grid-Connected Hybrid Inverter ...

All Rights Reserved

No part of this document can be reproduced in any form or by any means without the prior written permission of Sungrow Power Supply Co., Ltd. Trademarks and other Sungrow trademarks used in this manual are owned by Sungrow Power Supply Co., Ltd. All other trademarks or registered trademarks mentioned in this document are owned by their respective owners. Notice In no case shall this manual substitute for the user manual or related no ...

※ Installation of the copper is required in case of parallel PV input.

L A PV1 PV2 B L N N PE PE bar Neutral bar Home appliance Main Switch SUNGROW meter Utility Grid Copper A2 B2 1-phase sensor Li-ion battery ※ Circuit breaker Wiring diagram for a single-phase system with a Li-ion battery (CAN communication) Inverter inside The CT clamp of 1-phase sensor can be placed before or after the main switch. CANH CANL BAT_C ...

Wiring diagram for a three-phase system with a Li-ion battery (CAN communication)

※ Installation of the copper is required in case of parallel PV input. L3 N PE PE bar Neutral bar Home appliance Main Switch AC circuit breaker Utility Grid Copper ※ L1 L2 IN OUT A2 B2 Fuse (optional) Li-ion battery CANH CANL SUNGROW meter A B Load side Grid side Inverter inside PV1 PV2 CANH CANL BAT_Com . ...

Earth Fault Alarm

NO2 COM2 Router/Switch Direct mode SolarInfo Moni APP SolarInfo Bank Server SolarInfo Bank Webserver Explorer SolarInfo WiFi Light Buzzer 240V AC 2. The buzzer inside the inverter will beep if an earth fault occurs. Notice: Inverter inside DO1 COM1 NO1 DO2 COM2 NO2 1. The earth fault alarm can also be sent to your email by the SolarInfo Bank server. ...

※ Installation of the copper is required in case of parallel PV input.

L A PV1 PV2 B L N N PE PE bar Neutral bar Home appliance Main Switch Utility Grid 1-phase sensor Li-ion battery PV inverter Circuit breaker Retrofitting the existing PV system at a single-phase system Inverter inside The CT clamp of 1-phase sensor can be placed before or after the main switch. CANH CANL ...

※ Installation of the copper is required in case of parallel PV input.

Inverter inside L3 N PE PE bar Neutral bar Home appliance Main Switch AC circuit breaker Utility Grid Copper ※ L1 L2 A B A2 B2 Fuse (optional) Sungrow battery CANH CANL Retrofitting the existing PV system at a three-phase system PV inverter IN OUT SUNGROW meter Load side Grid side PV1 PV2 ...

System Overview ..................................................................... II

1 Installation ......................................................................... 1 1.1 Location Requirements ............................................................. 1 1.2 Installing the Inverter ................................................................. 2 1.3 Grounding the Inverter ...................................................... ...

LCD Menu ................................................................................ 35

5.4 Setting the Country Code ......................................................... 36 5.5 Setting the Protective Parameters ........................................... 37 5.6 Setting the Communication Parameters .................................. 38 6 Troubleshooting .............................................................. 39 6.1 Troubleshooting ...

1.1 Location Requirements

 The concrete wall should be suitable for the weight and dimensions of the inverter.  The location should be convenient for installation, cable connection and service.  The location should be not accessible to children.  The location should be away from flammable materials or gas, and the environment should not be enclosed. Flammable wall Flammable material or gas near the installation Closed cabine ...

Quick User Manual

2  Install vertically for sufficient heat dissipation.  Clearance requirements for single and multiple installation: 300mm 300mm 300mm 300mm 1.2 Installing the Inverter Install the inverter on the wall by means of the wall-mounting bracket and the expansion plug sets. The depth of the holes should be about 70 mm. Be sure to adhere to the following screw assembly sequence: self-tapping screw, spring washer, fender was ...

Quick User Manual

1 Installation 3 Place the expansion tubes Secure the bracket 4 3 5 6 Mount the inverter to the bracket Secure the inverter with two M5 screws and washers (3.0 N.m) 1.3 Grounding the Inverter A second protective earth (PE) terminal is equipped at the side of the inverter. Be sure to connect this PE terminal to the PE bar for reliable grounding. M5 Fig. 1-1 Second PE Terminal In no case shall the second PE connection substitute for the PE ...

Quick User Manual

4 Second PE Connection A B C D E Item Description Specification A Cable socket - B Washer - C Spring washer - D Screw M5 x 12 mm (3.0 Nm) E Yellow-green cable 6–10 mm 2 copper wire or 10–16 mm 2 aluminum wire 1.4 Installing the Meter The SUNGROW meter should be installed next to the main switch. It supports a 35 mm DIN-rail installation, as shown in the following figure. Single-phase Energy Meter Three-phase Energy ...

2 Electrical Connection

For the TT utility grid, the N line voltage to ground must be less than 30 V. 2.1 Terminal Description Connection terminals on the inner configuration circuit board are shown below: Fig. 2-1 Configuration Circuit Board Inside the Inverter No. Label Connection Tool Requirements 1 Copper PV (for parallel mode) Phillips screwdriver 2 Ethernet Communication - 3 DRM Local control for SPI (Italy) Flat-head screwdriver with an open end ...

2 Electrical Connection

Quick User Manual 6 No. Label Connection Tool Requirements 8 BAT_Com. (CANH, CANL) Battery communication mm 9 DO1 Power management 10 DO2 Earth fault alarm 11 BAT+, BAT- Battery Phillips screwdriver Terminals at the bottom of the inverter are shown below: Backup Ctrl Fig. 2-2 Terminals at the Bottom of the Inverter Label Description AC-Grid AC terminal to the utility grid. Backup Ctrl Reserved. PV1+, PV1-, PV2+, PV2- Terminals for t ...

Quick User Manual

2 Electrical Connection 7 2.2.1 For Three-phase Energy Meter Three-phase energy meter and its terminals are shown in the following figure. A D B C Designation Specification A L1, L2, L3, N Output terminals to the load side B Active PWR Glowing: 1000 impulse per kWh active power is detected. Off: no active power is detected. Reactive PWR Glowing: reactive power is detected. Off: no reactive power is detected. Com. Flashing: the meter is co ...

2 Electrical Connection

Quick User Manual 8 2. Strip the insulation from the power wires by 10 mm. Then connect the wires to the terminals on the Energy Meter, as shown below. (Cross-section: 10 mm2 to 25 mm2) OUT IN Load side Grid side  The line conductor L1 supplies power to the Energy Meter. At least the line conductor L1 and the neutral conductor must be connected to switch on the Energy Meter.  Just connect the line conductor L1 and the neutral ...

Quick User Manual

2 Electrical Connection 9 Designation Description 1000 imp/kWh Glowing: 1000 impulse per kWh active power is detected. Off: no active power is detected. D 3, 6 3 is for the line conductor 6 is for the neutral conductor E / CT clamp for the 1-phase sensor Proceed as follows to connect the cables. 1. Take out the meter (with 1-phase sensor) and the cables from the packaging. L N B A B2 A2 Power supply cable RS485 cable 2. Connect the cables ...

2 Electrical Connection

Quick User Manual 10 1 2 3 A2 B2 485 a b Note: For reconnection, press the part as shown in the red circle so as to pull out the cable. 2.3 Grid Connection Install an AC circuit breaker next to the AC output of the inverter. Inverter Type Specification for AC Circuit Breaker SH3K6 20 A SH4K6 32 A Make sure to disconnect the AC circuit breaker and secure it against reconnection before cable connection. PE L N 8mm–15 mm 40mm • Cr ...

Related Devices for Sungrow SH3K6:

SG125HV-30
Sungrow SG125HV-30
23.06.2026 105 pages

SG125HV-30-UEN-Ver11-202003 Version: 1.1 User Manual SG125HV-30 PV Grid-connected Inverter Instruction and reference manual for the Sungrow SG125HV-30 Inverter. It offers details on user settings, reset instructions, error handling.

SH3K6-30
Sungrow SH3K6-30
09.05.2026 133 pages

SH3.6_4.6_5K-30-UEN-Ver11-201908 Version:1.1 User Manual SH3K6 / SH4K6 / SH5K-30 Grid-Connected Hybrid Inverter User handbook for the Sungrow SH3K6-30 Inverter. This guide explains technical procedures for device calibration, startup procedures, technical overview, device features.

SG60KTL
Sungrow SG60KTL
14.07.2026 15 pages

1160mm 770mm 385mm User documentation for the Sungrow SG60KTL Inverter. It contains information on safety information, compatibility information, device operation tips, connectivity options.

T65
Sungrow T65
23.05.2026 11 pages

GD_202011_RT Series_3-Phase Hybrid Inverter Commissioning Guide_V1.0 Page 1 of 11 © Sungrow Australia Group Pty. Ltd. All rights reserved. As we continuously i User and installation guide for the Sungrow T65 Inverter. This reference manual explains device overview, device instructions, operational procedures.

COM100
Sungrow COM100
11.07.2026 32 pages

CCOOM M110000CCoom mm muunniiccaattiioonn BBooxxUUsseerr M MaannuuaallCCOOM M110000--VV2222--UUEENN-- VVeerr1111--220022000033 COM100-V22-UEN-Ver11-202003 COM10 General instruction manual for the Sungrow COM100 Conference System. It offers guidance for setup and maintenance, device calibration, application scenarios, network configuration.

eShow
Sungrow eShow
09.04.2026 30 pages

eShow V21-UEN-Ver11-201608 Version:1.1 User Manual eShow LCD module Device guide for the Sungrow eShow Control Unit. It details safety instructions and internal layout, product safety, troubleshooting tips.

SG36CX-US
Sungrow SG36CX-US
13.08.2026 109 pages

User Manual PV Grid-Connected Inverter SG36_60CX-US SG36_60CX-US-UEN-Ver11-202009 WWW.SUNGROWPOWER.COM User support guide for the Sungrow SG36CX-US Inverter. This manual covers specifications, wiring setup, performance details.

SC50HV
Sungrow SC50HV
03.06.2026 84 pages

SC50_60_75HV-UEN-V12-202006 Version: 1.2 User Manual SC50/60/75HV Power Conversion System (PCS) Technical operations guide for the Sungrow SC50HV Power Supply. This manual outlines software updates, connectivity setup, installation procedures.

Inverter: Frequently Requested PDF Instructions

SOL-GP
ATI Technologies SOL-GP
08.06.2026 32 pages

Pag. 1 / 32 210-0275 – edizione 2021-04 DOCCIA SOLARE DA ESTERNO MANUALE ISTRUZIONI OUTDOOR SOLAR SHOWER INSTRUCTION MANUAL DUCHA SOLAR EXTERIOR MANUAL DE INS Official installation manual for the ATI Technologies SOL-GP Bathroom Fixtures. It includes usage scenarios and setup, repair references, safety features.

030653-00
Briggs & Stratton 030653-00
17.03.2026 24 pages

Not for Reproduction BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC MILWAUKEE, WISCONSIN, U.S.A. Manual No. 80012591 Revision B Inverter Generator Operator’s Ma Usage and setup manual for the Briggs & Stratton 030653-00 Inverter. This documentation highlights features and installation guides, troubleshooting tips, connectivity options.

ULPSS20B2W/A
Winco ULPSS20B2W/A
12.03.2026 28 pages

1 12270-00 60706-229 INSTALLATION AND OPERATORS’ MANUAL PACKAGED STANDBY SYSTEM ULPSS20B2W/A Detailed product documentation for the Winco ULPSS20B2W/A Inverter. This guide offers guidance on maintenance guidelines, specifications, device instructions.

CT-I60012
Curtech CT-I60012
29.05.2026 14 pages

Pure Sine Wave Power Inverter DC-AC Inverter Available models: CT-I60012 CT-I100012 CT-I200012 CT-I300012 CT-I400012 CT-I100024 CT-I200024 CT-I300024 CT-I400024 Maintenance instructions for the Curtech CT-I60012 Inverter. The manual covers procedures for service contacts, connectivity setup, device features, warranty information.