Steiner M830r LRF Instruction Manual

File Specifications

Brand: Steiner
Category: Measuring Instruments
Model: M830r LRF (Instruction Manual), pr2AGbmmxGQ5s
File Type: PDF
File Size: —
Pages: 12 pages

Download PDF

Download Steiner M830r LRF Manual (12 pages)

Read Online:

Read the Steiner M830r LRF Instruction Manual online using the built-in PDF viewer.

Key Pages of Document

MILITARY RUGGEDNESS AND PRECISION

STEINER M830r LRF Laser Rangefinder with Reticle ...

Information for your safety ............................................................. 3

Disposal of electronical equipment ............................................... 3 Battery disposal ............................................................................... 3 Important notice for USA ................................ ...

INFORMATION FOR YOUR SAFETY

3 General information: The instrument meets the laser class 1 according to EN and FDA. It is classified as eye safe and can be used in any way. For safety precaution it should however not be pointed directly at people. User information for the disposal of electrical and electronic equipment (private households): This symbol on pro ...

IDENTIFICATION OF THE COMPONENTS

4 1a. Eyepiece with rubber eyecup, left 4. Set button 1b. Eyepiece with rubber eyecup, right 5. Battery compartment 2a. Diopter adjustment, left 6. Laser transmission optics 2b. Diopter adjustment, right 7. Tripod Adapter Screw 3. Button for distance measuring 4 3 2b 1b 5 6 2a 1a 7 ...

INSERING AND REPLACING THE BATTERY

5 Inserting and replacing the battery The laser range finder is powered by a type 3 volt CR 2 lithium battery. 1. To insert and replace the battery, unscrew the battery cover (5) by turning anticlockwise. 2. Insert the battery with the positive end forward (according to the symbol in the battery compartment). 3. Then screw ...

RANGE ESTIMATION ACCURACY

6 The STEINER M830r LRF Laser Rangefinder binocular has a measuring accuracy of up to ±1 meter/yard. The maximum range is achieved with highly reflective target objects and visibility of 10 km. The metering range is affected by the following factors: Range higher lower Color of object white black Angle to object vertical acute Size ...

Button for distance measuring (3)

To measure the distance to an object, you must lock onto it precisely. To do this, activate the target mark by pressing the button for distance measuring (3) for approx. 3 sec. Release the button to start the measurement and the estimated range is shown on the display. The illumination of the target ...

Set button (4)

The range can be displayed either in metres or in yards, as desired. After pressing the button for distance measuring (3) a ‘m’ for meter or ‘y’ for yards is displayed next to the target marker. To change the setting, use the SET button (4): An extended press of the button for over 3 seconds will cause the display ...

USE OF RETICLE

9 The right side of the binocular includes a horizontal and vertical scale reticle graduated in mil increment markings. In determing range, if an object fills on 10 mil unit marking on the horizontal reticle scale and is known to be 10 meters wide, the object is 1.000 meters away. If the same size object fills 20 mil unit markings, it would be ...

Blow away any dust or debris on the lenses.

To remove dirt or fingerprints, clean with cleaning cloth by rubbing in a circular motion. Use of a coarse cloth or unnecessary rubbing may scratch the lens surface and eventually cause permanent damage. For more thorough cleaning, use a lens cleaning fluid. Always apply the fluid to th ...