Sinclair ASDH-96AI Service Manual
Read Online
Read the Sinclair ASDH-96AI Service Manual online using the built-in PDF viewer.
Key Pages of Document
or operating your new air conditioning unit. Make sure to save this manual for future reference. ...
Part. 2 Outdoor Unit ........................................................... 5 Part. 3 Indoor Unit ............................................................ 13 Part. 4 Installation & Troubleshooting ........................... 24 Part. 5 Controller .............................................................. 52 ...
1. Model Names of Indoor/Outdoor Units .............................. 3 2. External Appearance ........................................................... 3 3. Nomenclature ....................................................................... 4 ...
Type Indoor unit Outdoor unit Model Power supply Model Power supply Hi-static pressure duct type ASDH-96AI 220-240V~, 1Ph, 50Hz ASDH-96AI 380-415V~, 3Ph, 50Hz 2. External Appearance 2.1 Indoor units ASDH-96AI 2.2 Outdoor unit ASDH-96AI ...
High static pressure Duct Sinclair Air conditioner Inverter R410A A S D H 96 A I 4 ...
1. Specifications ..................................................................... 6 2. Dimension (Unit:mm) ......................................................... 7 3. Refrigerant circuit .............................................................. 8 4. Wiring Diagrams ................................................................. 9 5. Electric Characteristics ................................................... 11 6. Sou ...
380-415V~, 3Ph, 50Hz Ambient temp in cooling °C -15~48 Ambient temp in heating °C -15~24 Rated input (Whole units) W 11,700 Rated current (Whole units) A 16 Compressor Model \ LNB53FCAMC Type \ Rotary Brand \ MITSUBISHI Quantity \ 1 Capacity kW 16.86 Input kW 5.2 Crankcase heater W 25 Refrigerant oil type \ FV50S Refrigerant oil charge mL 1700 + 1500 Outdoor fan motor Model \ WZDK170-38G-1 Ty ...
Design pressure (Hi/Lo) MPa 4.4/2.6 Refrigerant piping Liquid pipe mm Ф9.53 Gas pipe mm Ф25.4 Note: 1. The nominal cooling capacity is based on the following conditions: Indoor temperature, 27°C DB, 19°C WB; Outdoor temperature, 35°C DB, 24°C WB. 2. The nominal heating capacity is based on the following conditions: Indoor temperature, 20°C DB, ...
High pressure switch Oil seperator Oil return capilary Compressor Low pressure switch Low pressure liquid accumulator can Condensor High pressure liquid accumulator can Electronic expansion valve Evaporator SV5 SV6 ...
S5 function definition S6 function definition 1 2 3 S5 ON Heating priority mode (set by factory default) 1 2 S6 ON Automatic addressing 1 2 3 S5 ON Cooling priority mode 1 2 S6 ON Non-automatic addressing (set by factory default) 1 2 3 S5 ON Initial-start priority mode 1 2 S6 ON Clear indoor unit address 1 2 3 S5 ON Heating only mode 1 2 3 S5 ON Cooling only mode ENC2 function definition (Dial-up cannot be changed) ENC3 funct ...
H0 COMM. Fault between IR341 and main chip. H1 COMM. Fault between communication chip and main chip. H4 3 times of P6 protection in 30 minutes. H5 3 times of P2 protection in 30 minutes. H7 The number of indoor units decreases. H8 Reserved. HF M-HOME for the indoor and outdoor units does not match. E1 Reserved. E2 Communication fault between the outdoor and indoor units. E4 T3 & T4 temperature sensor fault. E5 Voltage protecti ...
Unit Number Model Noise level under three speeds of fan (dB(A)) 1 ASDH-96AI 59 7. Accessories Accessory name of outdoor unit Qty. Purpose Connection pipe 1 Connecting pipe of system Curved connection pipe 1 1m 1.3m Front ...
1.Features ............................................................................... 14 2.Specifications ..................................................................... 15 3.Dimensions (Unit: mm)....................................................... 16 4.Wiring Diagrams ................................................................. 17 5.Capacity Table ................................................................... ...
Convenient installation, hidden in the ceiling, unit installation is not hindered by the location of lighting fixtures or room structure. Air inlet and outlet flanges are standard and easy for duct connection. 1.2 External static pressure Three speed fan motor. External static pressure is up to 150Pa. The indoor air flow is up to 4800m3/h. 1.3 ...
220~240V,1Ph,50Hz Cooling Capacity W 28,000 Input W 9,000 EER W/W 3.11 Heating Capacity W 31,500 Input W 8,500 COP W/W 3.71 Rated input W 850 Rated current A 4.5 Indoor fan motor Model \ WZDK750-38GS-W Brand \ Panasonic Quantity \ 1 Speed r/min 1200/1160/1090 Indoor coil Number of rows \ 4 Tube pitch(a)×row pitch(b) mm 25.4×22 Fin spacing mm 1.5 Fin type \ Hydrophilic aluminum fin Tube size mm ...
Air outlet duct connection screw hole location diagram Return air duct rivet screw hole location diagram 122 194 194 272 272 254 390 1138 ...
Related Devices for Sinclair ASDH-96AI:
Advanced user manual for the Sinclair ZX Spectrum Desktop. The documentation includes details on support details, device safety checks, software installation.
Detailed user guide for the Sinclair SWM-04 Control Unit. This guide offers guidance on user preferences, service instructions, setup guidelines.
SINCLAIR ZX Spectrum 128 Service Manual Edited by Brendan Alford Spectrum For Everyone Website https://spectrumforeveryone.com/ Spectrum For Everyone Facebook G Complete user documentation for the Sinclair ZX Spectrum 128 Desktop. The guide covers usage and technical troubleshooting, device operation tips, reset instructions, product safety.
USER'S MANUAL MULTI COMBI SERIES FLOOR&CEILING MC-F09,12,18,24AI User operation guide for the Sinclair MC-F09AI Air Conditioner. It explains operation, maintenance, and performance details, safety, technical specifications.
SERVICE MANUAL ASH-13AIA PT, ASH-18AIA PT ARCTIC SERIE Step-by-step guide for the Sinclair ASH-13AIA PT Air Conditioner. This manual details component replacement, operational safety, maintenance guidelines, specifications.
1 Cutting System Operating Manual (800) 624-2408 (530) 626-9386 Fax (530) 626-5144 6686 Merchandise Way Diamond Springs, Ca 95619 www.sineqco.com Technical reference manual for the Sinclair Cutting System Saw. The guide describes usage and setup instructions, performance details, regulatory notices, installation steps.
INDOOR CASSETTE UNITS SDV5-56-140CA C O M M E R C I A L A I R C O N D I T I O N E R S S D V 5 Operating and setup manual for the Sinclair S D V 5 Series Air Conditioner. It provides instructions for support details, backup procedures, basic operation, component replacement.
USER'S MANUAL FLOOR & CEILING SERIES ASF-60AN remote controller Comprehensive user handbook for the Sinclair RG51Q/BGC Remote Control. This guide includes detailed instructions for user settings, operational procedures, performance guidelines, specifications.
Air Conditioner: Frequently Requested PDF Instructions
WARNING Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating and air-conditio Practical user guide for the Trane 4MYW4509A1 Air Conditioner. This manual describes setup, usage, and replacement parts, software updates, troubleshooting tips, compatibility information.
Operation guide for the Carrier 48SS018 Air Conditioner. The manual details backup procedures, service procedures, setup tips.
LG Floor Standing-Type Air Conditioner OWNER'S MANUAL LG IMPORTANT • Please read this owner's manual carefully and thoroughly before installing and operating Official user manual for the LG LF480CE Air Conditioner. The document offers guidance on product specifications, hardware components, menu navigation.
WATER SOURCE HEAT PUMP CEILING CASSETTE SPLIT TYPE AIR CONDITIONER (A SERIES) © 2006 McQuay International INSTALLATION MANUAL Group: WSHP Part Number: A0801902 User instruction booklet for the McQuay WSHP Air Conditioner. The manual contains instructions for system parameters, safety, firmware installation.