Operating manual – laser distance measuring device BD16 Warranty and liability
The device complies with the fundamental health and safety
requirements of the applicable EU regulations and was tested at
the factory for perfect functionality multiple times.
If malfunctions occur nonetheless, please contact your dealer or
distributor.
When making a warranty claim, supply the device number (see
label on the device).
When manufacturer's instructions or l
Operating manual – laser distance measuring device BD16 Residual risks
Warning of laser radiation
Laser class 2, P max.: > 1 mW, λ: 650 nm,
EN 60825-1:2014
Do not look directly into the laser beam or the opening
from which it emerges.
Never point the laser beam at people, animals or
reflective surfaces. Even brief eye contact can lead to
eye damage.
Examining the laser output aperture by use of optical
instruments (e.g. magnifying glass, magnifi
Operating manual – laser distance measuring device BD16 Device depiction
1
2
3
4
5
6
No.
Designation
1
Optical sensor
2
Laser
3
Battery compartment with cover
4
Spirit level
5
Operating elements
6
Display
Operating elements
3
3
2
2
1
1
1
2
3
7
8
9
10
4
No.
Operating element
7
Press briefly:
Switch-on/measurement button
Press for a long time:
Button for permanent distance measurements
8
Press briefly:
Function button (area, volume or indirect
measure
Operating manual – laser distance measuring device BD16 Technical data
Parameter
Value
Model:
BD16
Weight:
150 g
Dimensions (H x W x D):
120 x 42 x 24 mm
Measuring range:
0.05 to 40 m
Accuracy:
±3 mm*
Measuring range resolution: 1 mm
Number of recordings
logged in the history:
10
Type of protection:
IP54
Operating temperature:
0 °C to 40 °C
Storage temperature:
-20 °C to 70 °C
Laser output:
< 1 mW (620-690 nm)
Laser class:
II
Ø
10 mm / 10
Operating manual – laser distance measuring device BD16 Operation
Inserting the batteries
Insert the supplied batteries before first use.
Notice
Make sure that the surface of the device is dry and the
device is switched off.
Attaching the belt clip and wrist strap (optional)
Info
Please note that the belt clip has to be removed to
change the batteries (see chapter Battery change).
Using the belt clip as end piece
To stabilise the device, you can use
Operating manual – laser distance measuring device BD16 Switch-on
Warning of laser radiation
Laser class 2, P max.: > 1 mW, λ: 650 nm,
EN 60825-1:2014
Do not look directly into the laser beam or the opening
from which it emerges.
Never point the laser beam at people, animals or
reflective surfaces. Even brief eye contact can lead to
eye damage.
Examining the laser output aperture by use of optical
instruments (e.g. magnifying glass, magnifiers a
Operating manual – laser distance measuring device BD16 Adding / subtracting measured values
1.
Carry out a single distance measurement.
2.
To add a measured value, briefly press the Plus/Minus
button (9) one time.
To subtract a measured value, briefly press the Plus/Minus
button (9) twice.
3.
Press the Switch-on/measurement button (7) to determine
the next measured value.
ð The overall result will be indicated in the lower
measurement value dis
Operating manual – laser distance measuring device BD16 Indirect height measurement (Pythagoras)
Using this method the length of an unknown straight-line
segment can be determined via the Pythagorean Theorem. This
method is suitable for e.g. height measurements.
A
B
Measurement requirements:
•
The device is aligned horizontally to the lowest point (B) of
the line segment to be determined.
•
The reference point is located at the rear of the devic
Operating manual – laser distance measuring device BD16 Fault indications
The following fault indications can appear in the lower
measurement value display together with the word INFO:
Display
Cause
Remedy
101
The reception of the
reflected signal is too
weak.
Repeat measurement on another
surface with better reflective
properties or use a target plate.
102
The reception of the
reflected signal is too
strong.
201
The ambient light is too
intense.
C
Operating manual – laser distance measuring device BD16 Cleaning
Clean the device with a soft, damp and lint-free cloth. Ensure
that no moisture enters the housing. Do not use any sprays,
solvents, alcohol-based cleaning agents or abrasive cleaners,
but only clean water to moisten the cloth.
Repair
Do not modify the device or install any spare parts. For repairs
or device testing, contact the manufacturer.
Disposal
The icon with the crossed-out was
Trotec BD16 Trotec GmbH & Co. KG
Grebbener Str. 7
D-52525 Heinsberg
+49 2452 962-400
+49 2452 962-200
[email protected]
www.trotec.com