Operating manual – laser distance measuring device BD16

Table of contents Notes regarding the operating manual................................. 1 Safety..................................................................................... 2 Information about the device................................................ 3 Transport and storage........................................................... 5 Operation .....................................
Operating manual – laser distance measuring device BD16 Warranty and liability The device complies with the fundamental health and safety requirements of the applicable EU regulations and was tested at the factory for perfect functionality multiple times. If malfunctions occur nonetheless, please contact your dealer or distributor. When making a warranty claim, supply the device number (see label on the device). When manufacturer's instructions or l
Operating manual – laser distance measuring device BD16 Residual risks Warning of laser radiation Laser class 2, P max.: > 1 mW, λ: 650 nm, EN 60825-1:2014 Do not look directly into the laser beam or the opening from which it emerges. Never point the laser beam at people, animals or reflective surfaces. Even brief eye contact can lead to eye damage. Examining the laser output aperture by use of optical instruments (e.g. magnifying glass, magnifi
Operating manual – laser distance measuring device BD16 Device depiction 1 2 3 4 5 6 No. Designation 1 Optical sensor 2 Laser 3 Battery compartment with cover 4 Spirit level 5 Operating elements 6 Display Operating elements 3 3 2 2 1 1 1 2 3 7 8 9 10 4 No. Operating element 7 Press briefly: Switch-on/measurement button Press for a long time: Button for permanent distance measurements 8 Press briefly: Function button (area, volume or indirect measure
Operating manual – laser distance measuring device BD16 Technical data Parameter Value Model: BD16 Weight: 150 g Dimensions (H x W x D): 120 x 42 x 24 mm Measuring range: 0.05 to 40 m Accuracy: ±3 mm* Measuring range resolution: 1 mm Number of recordings logged in the history: 10 Type of protection: IP54 Operating temperature: 0 °C to 40 °C Storage temperature: -20 °C to 70 °C Laser output: < 1 mW (620-690 nm) Laser class: II Ø 10 mm / 10 
Operating manual – laser distance measuring device BD16 Operation Inserting the batteries Insert the supplied batteries before first use. Notice Make sure that the surface of the device is dry and the device is switched off. Attaching the belt clip and wrist strap (optional) Info Please note that the belt clip has to be removed to change the batteries (see chapter Battery change). Using the belt clip as end piece To stabilise the device, you can use
Operating manual – laser distance measuring device BD16 Switch-on Warning of laser radiation Laser class 2, P max.: > 1 mW, λ: 650 nm, EN 60825-1:2014 Do not look directly into the laser beam or the opening from which it emerges. Never point the laser beam at people, animals or reflective surfaces. Even brief eye contact can lead to eye damage. Examining the laser output aperture by use of optical instruments (e.g. magnifying glass, magnifiers a
Operating manual – laser distance measuring device BD16 Adding / subtracting measured values 1. Carry out a single distance measurement. 2. To add a measured value, briefly press the Plus/Minus button (9) one time. To subtract a measured value, briefly press the Plus/Minus button (9) twice. 3. Press the Switch-on/measurement button (7) to determine the next measured value. ð The overall result will be indicated in the lower measurement value dis
Operating manual – laser distance measuring device BD16 Indirect height measurement (Pythagoras) Using this method the length of an unknown straight-line segment can be determined via the Pythagorean Theorem. This method is suitable for e.g. height measurements. A B Measurement requirements: • The device is aligned horizontally to the lowest point (B) of the line segment to be determined. • The reference point is located at the rear of the devic
Operating manual – laser distance measuring device BD16 Fault indications The following fault indications can appear in the lower measurement value display together with the word INFO: Display Cause Remedy 101 The reception of the reflected signal is too weak. Repeat measurement on another surface with better reflective properties or use a target plate. 102 The reception of the reflected signal is too strong. 201 The ambient light is too intense. C
Operating manual – laser distance measuring device BD16 Cleaning Clean the device with a soft, damp and lint-free cloth. Ensure that no moisture enters the housing. Do not use any sprays, solvents, alcohol-based cleaning agents or abrasive cleaners, but only clean water to moisten the cloth. Repair Do not modify the device or install any spare parts. For repairs or device testing, contact the manufacturer. Disposal The icon with the crossed-out was