Euroterm 2116 Installing And Operating Instructions
File Specifications
| Brand: | Euroterm |
| Category: | Temperature Controller |
| Model: | 2116 (Installing And Operating Instructions), prpAe4Dw8231M |
| File Info: | Adobe Acrobat PDF (DjVu) |
| File Size: | — |
| Pages: | 13 pages |
Download PDF
Download Euroterm 2116 Manual (13 pages)Read Online:
Read the Euroterm 2116 Installing And Operating Instructions online using the built-in PDF viewer. This document explains how to operate the device, adjust settings and perform regular maintenance.
Key Pages of Document
Issue 2, Nov-98. Applies to software versions 1.3 & 1.4 -11- HA026270
ORDERING CODE The controller is supplied configured according to the ordering code shown below. Model number Function Supply voltage Manual Output 1 (Logic) Output 2 (Relay) Sensor input Setpoint min Setpoint max Units External relay module Input adaptor 2132 2116 TECHNICAL SPECIFICATION Panel sealing IP65 (EN 60529), or 4X (NEMA 250) Operating ambients 0 to 55oC. Ensure that the enclosure is adequately vent ...
Issue 2, Nov-98. Applies to software versions 1.3 & 1.4 -7- HA026270
..........Timer Operating Modes continued - Mode 3, Time from Cold and Switch Off This is the same as mode 1 except that the timer will start counting down immediately without waiting for the temperature to reach setpoint. Mode 4, Time from Cold No Switch Off This is the same as mode 2 except that the timer will start counting down without waiting for the controller to reach setpoint. Mode 5, ...
Issue 2, Nov-98. Applies to software versions 1.3 & 1.4 -7- HA026270
..........Timer Operating Modes continued - Mode 3, Time from Cold and Switch Off This is the same as mode 1 except that the timer will start counting down immediately without waiting for the temperature to reach setpoint. Mode 4, Time from Cold No Switch Off This is the same as mode 2 except that the timer will start counting down without waiting for the controller to reach setpoint. Mode 5, ...
Issue 2, Nov-98. Applies to software versions 1.3 & 1.4 -9- HA026270
Relay and Logic input/output Configuration Note: The logic I/O can be configured as an output or a contact closure input for alarm acknowledge, keylock, or timer run/reset. Relay output Options Meaning Logic I/O Identity of output - Relay . Logic Function . Digital (alarm) output Heating output Cooling output These functions ' PDSIO mode 1 are only appear Alarm Acknowledg ...
Issue 2, Nov-98. Applies to software versions 1.3 & 1.4 -10- HA026270
AUTOMATIC TUNING In PID control, the output from the controller is the sum of three terms: Proportional, Integral and Derivative. These three terms deliver just the right amount of power to hold the temperature at setpoint without oscillation. For stable control, the PID values must be ‘tuned’ to the characteristics of the process being controlled. In the 2132 and 2116 this is done automatically using a ...
Issue 2, Nov-98. Applies to software versions 1.3 & 1.4 -5- HA026270
Automatic Tuning List (See page 10) Adjustable Range Default Setting Customer setting Automatic Tune Enable or !! " Automatic Manual reset calculation (when P+D control) or # # PID List (See page 10) Adjustable Range Default Setting Customer setting Proportional Band to display units Integral Time to seconds $ Derivative Time to seconds ...
Issue 2, Nov-98. Applies to software versions 1.3 & 1.4 -12- HA026270
SERVICE AND REPAIR This controller has no user serviceable parts. Contact your nearest Eurotherm Controls agent for repair. Caution: Charged capacitors Before removing the controller from its sleeve, switch off the supply and wait two minutes to allow capacitors to discharge. Failure to observe this precaution may damage the indicator or cause some discomfort to the user. Electrostatic discharge precautions ...
Euroterm 2116 user guide recommended for: Desert Fog Revolution 93800, LFI-3500 Series, ECL Comfort 296, CMa11L, E1000.
⚠️ Download Safety
The Temperature Controller Installing and operating instructions (13 pages) is completely safe to download (last scan date: 27/06/2026).
Related PDF Instructions for Euroterm 2116:
-
Euroterm EURO ONE Water Heater Installation and maintenance manual
EURO ONE64 -
Euroterm E25 Boiler Instructions for use, installation & maintenance
E2524 -
Euroterm EURO ONE Water Heater Operation & user’s manual
EURO ONE28 -
Euroterm 2604 Controller Installation and wiring instructions
26042 -
Euroterm 2116 Temperature Controller Installing and operating instructions
211613 -
Euroterm SI 11 S Water Heater Instructions for use, installation and maintenance
SI 11 S20
Temperature Controller Equipment: Frequently Requested
-
dixell XW270L Temperature Controller
25.01.2026Technical setup manual for the dixell XW270L Temperature Controller. It provides guidance on hardware components, connectivity setup, calibration steps.XW270L, 4 -
Solo SL4848 Series Temperature Controller
10.03.2026Instruction booklet for the Solo SL4848 Series Temperature Controller. It covers topics such as support details, operating modes, setup.SL4848 Series, 4 -
Vaisala CARBOCAP GMW80 Series Transmitter
30.01.2026Device setup manual for the Vaisala CARBOCAP GMW80 Series Transmitter. The manual provides step-by-step instructions on product safety, troubleshooting guides, specifications, reset instructions.CARBOCAP GMW80 Series, 18 -
Lakeshore 325 Temperature Controller
22.02.2026Operation instructions for the Lakeshore 325 Temperature Controller. The manual highlights troubleshooting tips, error codes, product handling, setup validation.325, 166 -
Danfoss FP735Si Temperature Controller
04.06.2026Operating instructions for the Danfoss FP735Si Temperature Controller. It outlines the setup and maintenance, dimensions and layout, hardware setup.FP735Si, 24 -
Plugwise Jip Temperature Controller
09.04.2026Setup instructions for the Plugwise Jip Temperature Controller. The document explains system configuration, device operation tips, specifications, maintenance procedures.Jip, 2
Have some Questions about Euroterm 2116 Device?
Get valuable and actionable advices from other Euroterm 2116 device users. Describe your problem or question, regarding the using of 2116, in as much detail as possible, and other users will be able to answer you.