Extech Instruments BT100 Operation & User’s Manual
| Brand: | Extech Instruments |
| Category: | Multimeter |
| Model: | BT100 (Operation & User’s Manual) |
| File Type: | |
| File Size: | — |
| Pages: | 14 |
Text of Extech Instruments BT100 Operation & User’s Manual
Version 2.1 7/09
2
Introduction
The Battery Tester is designed for measuring the internal resistance and output voltage of
batteries including lead storage cell, nickel-cadmium battery, lithium-ion battery and nickel-
metal hydride battery.
z
AC four-terminal method to eliminates lead resistances and contact resistances and
yield the most accurate results.
z
1kHz test current with up to 10µΩ resistance resolution.
z
Dual display simultaneously indicates
Version 2.1 7/09 3
Specifications
Measuring method:
Resistance (AC four-terminal method).
A/D conversion:
Dual slope method.
Display:
Dual display LCD and LEDs (comparator output).
Sampling rate:
1 set (resistance & voltage measurements)/second.
Open-Circuit terminal voltage:
3.5Vpp max.
Input over range:
“OL” display.
Low battery detection:
display.
Test current fault detection:
“- - - -” display.
Auto power off:
After approximately 30 minutes.
Version 2.1 7/09 4
Electrical Specifications
Conditions to guarantee accuracy:
Temperature:
23°C ± 5°
Humidity:
80%RH or less (non-condensing).
Zero adjustment:
After zero adjustment for each range.
Resistance measurement
Temperature coefficient:
(±0.1% rdg ± 0.5digits)/°C
Measuring current frequency:
1KHz ± 10%
Measuring burden voltage:
1.5mVAC
Range
Resolution
Measurement current
Accuracy
40mΩ
10µΩ
37.5mA approx.
400mΩ
100µΩ
3.75mA appro
Version 2.1 7/09 5
Meter Description
1.
Power button: Power on /off
2.
R READ button:
c Press R button to show the manual
logged readings.
d Press R READ button again to stop
reading.
3.
M MEMORY button:
c Under the manual logging mode, the
tester stores each single set of logged
reading to the memory by pressing
M MEMORY button.
d Press and hold M MEMORY button
for 2 seconds to enter continuous
logging mode. Press again to stop
logging.
4.
V-R
Version 2.1 7/09 6
Display Description
1. Measured resistance reading (High or Low limit of resistance on the comparator
settings)
2. Measured voltage reading (High or Low limit of voltage on the comparator settings).
3. The assigned number of comparator: 99 sets
4. The location for the manual logged data.
5. Symbols:
mΩ:
Milliohm (resistance).
V:
Voltage.
HOLD :
Hold function.
COMP :
Comparator function enabled.
:
Low-Battery
:
Beeper enabled
DATA R
Version 2.1 7/09 7
Basic Operation
Preparation
The following safety information must be observed to ensure maximum personal safety
during the operation of this tester.
z To avoid electric shock when replacing the batteries first disconnect the leads from the
object to be measured.
z Check the battery polarity carefully when inserting the batteries.
z Be sure to dispose of used batteries properly.
1.
Remove the battery cover.
2.
Insert the batteries into th