OPERATING INSTRUCTIONS Fuel Door Operation Riddling Grate Lighting Controlling The Fire Refuelling Maintenance Throat Plate & Flueway Clearing Chimney Sweeping Trouble Shooting If You Need Further Help Health & Safety Precautions Specification Chimney Hearth & Fire Surround Connection to Flues External Air Supply Soot Doors Unpacking The Stove Pre Lighting Check Commissioning Tor Dimensions Tor Parts Lists Certification 3 3 3 4 4 5 5 6 6 7 7 8 8 8 9 9 9 9 9 10 10 11 12 - 16 23 INSTALLATION INSTRUCTIONS Ash Clearance Tor Pico Dimensions Tor Pico Parts Lists 3 17 18 - 22 Revision. Tor & Tor Pico 06.13 Issue G TOR & TOR PICO ...
fuels. Your Charnwood Tor is fitted with a riddling grate to enable wood to be burned and ash to be cleared. Whilst riddling the grate bars are rotated to the vertical position to clear an excessive buildup of ash. Ensure the grate bars rotate back to the horizontal position when the handle is released. Movement of the grate from one position to the other is effected by pulling the riddling handle as shown in Fig. 1. When burning wood the ash should be allowed to build up and riddling should only be carried out once or twice a week. Allow the ash level to rise up to the slots in the ...
The ash bin should be emptied when the level of ash reaches approximately three quarters full. Once the bin has been removed from the stove the lid can be pivoted into position to prevent ash escaping while the bin is being carried. The stove may be lit using dry kindling wood and paper or fire lighters. Place the paper, or fire lighters, and kindling on the grate and cover with a few small dry logs. Open the air control fully (see Fig. 1). Light the paper or fire lighters. Close the door until the fuel is well ignited then load with fuel. On initial lighting, the stove may smoke and give ...
More logs added to fire Larger logs can be added once the fire is well established. Once long flames appear over the fire reduce the air setting to 3. We normally anticipate running the fire at this setting for at least the first hour if starting the Tor from cold. Once the fire is well established – with each log alight at the top the air setting can be reduced to 2 or lower according to the type of fire required. If at any setting the flames start to go out or the glass begins to discolour, then this indicates that a higher setting is required. To achieve this pull the air control out to re-establ ...
Aerosol spray cleaners must not be used near the appliance whilst it is under fire. If the fire is going to be out of use for a long period (for instance in the summer) then to prevent condensation, and hence corrosion, the air control should be left fully open and the fire door left ajar. It is also advisable to sweep the chimney and clean out the fire. Spraying the inside of the door and firebox with a light oil, such as WD40, will also help to keep all internal parts working well. After long periods where the fire has been out of use, the chimney and appliance flueways should be cleane ...
Blackening of Glass Fume Emission Check that: a) the air inlet is not obstructed in any way, b) chimneys and flueways are clear, c) a suitable fuel is being used, d) there is an adequate air supply into the room, e) an extractor fan is not fitted in the same room as the stove. f) there is sufficient draw in the chimney (once the chimney is warm a draught reading of at least 0.10 inches water gauge (25Pa) should be obtained). Keeping the glass clean requires a certain amount of experimentation due to the differences in the draw of different chimneys. The following points should be noted and with a little care should e ...
In addition to these instructions the requirements of BS 8303 and BS EN 15287-1 :2007 must be fulfilled. Local Authority Bylaws and Building Regulations regarding the installation of Solid Fuel burning appliances, flues and chimneys must also be observed, including those referring to national and European Standards. Building regulations require that whenever a new or replacement fixed solid fuel or wood/biomass appliance is installed in a dwelling a carbon monoxide alarm must be fitted in the same room as the appliance. Further guidance on the installation of the carbon monoxide alarm is available in BS EN 50292:2002 and fro ...
The stove must stand on a fireproof hearth and must be situated at least the following distances from any combustible material: Tor Tor Pico Side Back 800mm (32in) 800mm (32in) 500mm (20in) 400mm (16in) The hearth must be at least 12mm (0.5inches) thick and capable of supporting the weight of the stove. The positioning of the stove and the size of the hearth are governed by building regulations for Class 1 appliances. These building regulations state that the hearth must extend in front of the stove by at least 300mm (12 inches) and to the sides of the stove by at least 150mm (6 inches). When the fire door is open, it extend ...
COMMISSIONING Before initial lighting the following points should be checked: 1. The bottom grate bars should move freely and easily when the riddling mechanism is operated. 2. The plates round the sides and back of the grate must be in position and sitting correctly. 3. The throat plate must be fitted carefully in the roof of the appliance. PLEASE NOTE great care must be taken to avoid hitting the glass whilst installing the throat plate. The method of location and positioning of the throat plate is shown in Fig. 7. On completion of the installation and after allowing a suitable ...
Description. In case of difficulty contact the manufacturer at the address shown. This drawing is for identification purposes only. * These items are not shown on the drawing. # Please specify colour when ordering. ® charnwood BISHOPS WAY, NEWPORT, ISLE OF WIGHT PO30 5WS, UNITED KINGDOM T:+44 (0)1983 537799 • F:+44 (0)1983 537788 • [email protected] • WWW.CHARNWOOD.COM 12 Item Part No. Description Item Part No. Description 1# 002/ES01/A Door Assembly 2# 004/ES01/04 Glass Support 3# 004/ES01/07 Glass Retainer Front 4# 010/ES01/16 Hinge Assem ...
T:+44 (0)1983 537799 • F:+44 (0)1983 537788 • [email protected] • WWW.CHARNWOOD.COM ® TOR charnwood TOR PARTS LIST GRATE ASSEMBLY 13 Item Part No. Description 1 010/ES07/04 L.H. Sideplate Assy 2 010/ES07/06 R.H. Sideplate Assy 3 004/ES07/07 Brick Retainer 4 010/ES07/08 Front Fence 5 010/ES07/09 Side Fence 6 010/ES08/01 R.H. Grate Support 7 010/ES08/02 L.H. Grate Support 8 010/ES08/03 Rear Grate Link Plate 9 010/ES08/04 Front Grate Plate 10 010/ES08/05 Link Plate 11 010/ES08/06 Grate End Bar 1 ...
T:+44 (0)1983 537799 • F:+44 (0)1983 537788 • [email protected] • WWW.CHARNWOOD.COM ® TOR charnwood TOR PARTS LIST AIR CONTROL 14 Item Part No. Description Item Part No. Description 1 010/ES15/05 Mounting Box 2 004/ES15/02 Connecting Rod 3 004/ES15/03 Air Flow Link Rod 4 004/ES15/04 Front Connector 5 008/ES15/11 Air Control Knob 6 008/ES15/16 PTFE Washer 7 004/ES15/21 Slide Front 8 004/ES15/22 Front Air Box 9 004/ES15/24 Air Slide 10 008/ES15/26 PTFE Slide Strip 11 0 ...
14 9 3 1 12 11 6 10 13 8 4 5 2 7 Item Part No. Description 1 010/ES08/12 Ash flap link 2# 008/ES15/01 Slide handle 3 008/ES15/08 PTFE slider 4 008/ES15/09 Spacer 5 008/ES15/10 Washer 6 004/ES15/17 Slide assy 7 008/FFS064 M8 x 25 Hex Hd Screw 8 008/FFW005 Washer 15x8.5 9 008/FFW002 Washer 14x6 10 008/FFP008 Clevis pin 8mm dia x60 11 008/FFP007 Clevis pin 6mm dia x16 12 008/FFP006 Splitpin 13 008/FFM043 Spring LEM 095D 12S 14 008/FFS044 Plastite fixing ® charnwood BISHOPS WAY, NEWPORT, ISLE OF WIGHT PO30 5WS, UNITED KINGDOM T:+44 (0)1983 537799 • F:+44 (0)1983 537788 • SPARES@CHARNWO ...
T:+44 (0)1983 537799 • F:+44 (0)1983 537788 • [email protected] • WWW.CHARNWOOD.COM ® TOR charnwood TOR PARTS LIST COLUMN 16 9 12 11 4 8 18 10 5 1 2 15 13 14 6 7 17 19 3 Item Part No. Description 1 004/ES06/12 Ash Guide 2 008/ES06/16 Gasket Ash Flap 3 008/ES06/17 Gasket Column 4 004/ES06/19 L.H. Column Side 5 004/ES06/20 R.H. Column Side 6 008/ES06/21 Bearing Ash Flap 7 008/ES06/22 Flap Pivot 8 008/ES06/23 Ash Door Seal 9 004/ES06/10 Ash Door Assy 10 010/ES06/25 Column Body 11 010/ES06/26 Hinge Upper 12 010/ES06/27 Hinge Lower 13 004/ES08/08 ...
17 144 482 FRONT VIEW SIDE VIEW 533 992 478 PLAN VIEW 130 161 144 Flue Outlet to suit 150mm (6") Fluepipe TOR PICO ...
Description. In case of difficulty contact the manufacturer at the address shown. This drawing is for identification purposes only. * These items are not shown on the drawing. # Please specify colour when ordering. ® charnwood BISHOPS WAY, NEWPORT, ISLE OF WIGHT PO30 5WS, UNITED KINGDOM T:+44 (0)1983 537799 • F:+44 (0)1983 537788 • [email protected] • WWW.CHARNWOOD.COM ® charnwood TOR PICO PARTS LIST TOR PICO Issue G Item Part No. Description Item Part No. Description 1# 001/KS010 KS Firebox 2# 002/KS001/A Door Assembly 3 008/KS011/A Ha ...
T:+44 (0)1983 537799 • F:+44 (0)1983 537788 • [email protected] • WWW.CHARNWOOD.COM ® charnwood TOR PICO PARTS LIST GRATE ASSEMBLY 7 9 14 1 17 13 15 8 2 5 10 6 14 4 11 3 12 16 3 5 TOR PICO Item Part No. Description 1 010/KS058 LH Sideplate 2 010/KS059 RH Sideplate 3 004/KS128 Brick Retainer 4 010/KS123 Front Fence 5 010/KS119 Side Fence 6 010/KS122 Grate Support 7 010/KS117 Grate Support Plate 8 010/KS056 Rear Grate Plate 9 010/KS057 Front Grate Plate 10 010/KS055 Link Plate 11 010/KS062 Grate Front & Rear Bar 12 002/CG21 CG20 Grate Bar Wi ...
Wood stove PDF Instructions
User instruction booklet for the Jøtul I 520 F Indoor Fireplace. It details operating modes and system configuration, component overview, cleaning instructions, functional overview.
READ AND KEEP THIS MANUAL FOR REFERENCE 45299 STEERS E.P.A. WOOD STOVE MANUAL US ENVIRONMENTAL PROTECTION AGENCY PHASE II CERTIFIED WOOD STOVE Verified and tested following ULC S627 and UL 1482 Standards by: Distributed by STEERS Manufactured by : STOVE BUILDE Manual for installation and usage of the STEERS AGENCY PHASE II Wood stove. This documentation highlights features and setup, user instructions, technical overview.
Usage and setup manual for the Jøtul F600 Indoor Fireplace. The document covers basic operation, installation, maintenance schedule.
1 7060-227J August 13, 2018 NOTICE: DO NOT DISCARD THIS MANUAL EXPLORER III WOOD APPLIANCE MODELS: EXPLR-III-PBK EXPLR-III-PDB EXPLR-III-PFT EXPLR-III-PMH EXPLR-III-MBK Installation and service of this appliance should be performed by qualified personnel. Hear Full operation manual for the Quadra-Fire EXPLORER III Series Indoor Fireplace. It describes step-by-step safety guidelines, system parameters, device instructions.