Contura 510 Installation Instructions Manual
Read Online
Read the Contura 510 Installation Instructions Manual online using the built-in PDF viewer.
510 Installation Instructions Manual: Key Pages of Document
www.contura.eu SE DE GB NO LEK ...
May we take this opportunity to wish you a warm welcome to the growing family of happy and satisfied owners of a Contura stove. Your choice is testimony to the high standards you demand in terms of quality and design. You can rest assu- red that your new Contura stove will serve you well and keep its good looks for many years to come. The Contura 500 is not only an efficient source of heat, but it is environmentally friendly as well. Please read through these instructions carefully before starting installation work, and study the separate Lighting and Maintenance Instructions before lighting a fire for the first time. Conten ...
very hot and can cause burn injury if touched. Be aware of the strong heat radiated through the hatch glass. Placing flammable material closer than the safe distance indicated may cause a fire. Pyre lighting can cause quick gas ignition with the risk of damage to property and personal injury. Quality approval The stove has been tested by the Swedish National Testing and Research Institute and meets the applicable regulations for CE marking and the stricter requirements for P marking. Certificate number for P Marking: 22 03 09 Manufacturer’s assurance Manufacture of the product has ...
to support the weight of the stove and chimney. If you intend to locate the stove on standard wooden floor joists, contact a professional builder to make sure that the construction will withstand the load. If the total weight does not exceed 400 kilos, it is not usually necessary to reinforce the joists. Floor plate To protect the floor from sparks and falling embers the stove must stand on a non-combustible surface which extends at least 300 mm in front of the stove and 100 mm along each side. As other st ...
brick or concrete 310 65 629 773 Combustible wall 750 468 240 100 100 200 300 400 60 160 260 360 Combustible wall D 300 139 97 B 850 A 942 C 340 30 470 Air inlet Ø67 Ø150 564 2000 1032 Air inlet Ø67 Combustible roof 320* 38* 190 50 700 1100 Fire-retardant wall of brick or concrete 310 100 595 740 Combustible wall 750 500 240 100 100 200 300 400 60 160 260 360 Combustible wall D 300 139 97 B 850 A 942 C 340 30 438 Air inlet Ø67 Ø150 1010 496 2000 Air inlet Ø67 Combustible roof 280 70 565 670 800 800 Fire-retardant wall of brick or concrete 320* 700 1100 70* 190 50 Fire-retardant wall of brick or ...
brick or concrete 1010 496 2000 Air inlet Ø67 Combustible roof 750 500 240 100 100 200 300 400 60 160 260 360 Combustible wall D 300 139 97 B 850 A 942 C 340 30 438 Air inlet Ø67 Ø150 310 100 595 740 Combustible wall 280 70 565 670 800 800 Fire-retardant wall of brick or concrete 310 80 615 760 Combustible wall 750 480 240 100 100 200 300 400 60 160 260 360 Combustible wall 1010 536 2000 Air inlet Ø67 Combustible roof 320* 50* 190 50 700 1100 Fire-retardant wall of brick or concrete D 300 139 B 850 A 942 C 340 30 458 97 Air inlet Ø67 Ø150 280 70 565 670 800 800 Fire-retardant wall of bric ...
Combustible roof 280 70 565 670 800 800 Fire-retardant wall of brick or concrete 320* 700 1100 70* 190 50 Fire-retardant wall of brick or concrete D 330 190 B 880 A 972 C 370 30 139 438 Air inlet Ø67 Ø150 580 *See 570 310 100 595 740 Combustible wall 750 500 240 100 100 200 300 400 60 160 260 360 Combustible wall 1156 496 2200 Ø 510 Air inlet Ø67 Combustible roof 280 70 565 670 800 800 Fire-retardant wall of brick or concrete 320* 700 1100 70* 190 50 Fire-retardant wall of brick or concrete D 446 190 B 996 A ...
Indirect air supply through the external wall. Through the floor and foundation slab. Through a suspended floor/wall-and-cavity foundation. Air supply Combustion air for the stove can be supplied through a duct directly from outside, or indirectly through a vent in the wall of the room where the stove is installed. The drawings on the right show various alternative methods of supplying the stove with air. The air duct connection on the stove has an external diameter of 64 mm. The stove has two partly punched covers to provide the option of leading the air supply duct through the rear panel or the ...
disc to disengage it from the pin on the grate shuttle. Lift up the smoke baffle and remo- ve the side section. Lift the smoke baffle out and remo- ve the remaining sections. Lift the heat reflector under the fire-box upwards, and ease it gently backwards to disengage it. Then, angling the front edge slightly downwards, remove the reflector completely. Leave all the components on one side until you have fitted the stove surround and the stove is standing in place. Then replace the components in reverse order. Unpacking Leave the stove body screwed in place on the deli- very pallet. Remove the components and ...
connecting to a top flue. To prepare the stove for connection to a rear flue, the connecting collar and covering cap need to change places. LEK Top flue connection to a chimney When installing the chimney, please refer to the manufacturer’s installation instructions. Below we explain how to connect the chimney to the stove. Top flue connection Slide the flue base over the collar. Make sure that the seal round the collar is not dislodged. If further sealing material is required, heat-resistant sealant may be used. LEK LEK Fit the connecting sleeve between the stove and the flue collar in the wall. ...
Lay the stove body on its back on the pallet. Secure the base-plate with four socket-head (female) screws. Fit them from the inside of the base-frame into the fix- ing lugs on the base-plate. Do not tighten the screws until the stove is standing upright on a level surface. 10 10 VANADIUM No. 7 CHROME x 3 Loosen the two screws on the rear of the base-frame by turning them three revolutions anticlockwise. Then hook the rear panel into place. Secure the rear panel by inserting two hexagon screws at the top and tightening them just 2 or 3 revolutions. Tighten the two screws that hold the bottom of the ...
head screw on the top edge at the front. 2. Tighten the other screws on the rear panel. 10 10 VANADIUM No. 7 CHROME 1 2 LEK Fitting the stove top Lay the soapstone stove top (or alternatively a slat- ted top or cast-iron top) carefully in place. Place the hot-air vent and covering cap on the soapstone stove top. Manufacturer’s markings Important! Before the stove is used, it must be inspected by an authorised chimney sweep or the relevant aut- hority. Please read carefully through the separate “Lighting and Maintenance Instructions for the Contura 500 series” before lighting ...
Lay the stove body on its back on the pallet. Install the base plate with four Allen screws. Screw from the inside of the base frame into the base plate mounting lugs. Tighten the screws when the stove has been raised and is standing on a flat surface. Slacken off the two rear screws for the base frame by three revolutions and hook the rear panel into place. Secure the rear panel with two hexagon screws at the upper edge, only screw these in 2-3 turns. Tighten the two lower screws for the rear panel. Slacken off the two upper screws on the fro ...
Position the stove body on the hearth plate and check the installation distances. Connection to the chimney from the rear of the stove body is carried out prior to installing the soapstone. When connecting the chimney to the top of the stove body the soapstone surround must be installed first. Remember to install the hot air vent before the top connection is made. Lift the soapstone top and sides from the packaging. Handle soapstone with care, the edges are susceptible to damage. Place the sides on polystyrene on a firm base. Screw a concrete screw into one end of each soapstone side, see the figure below. Tighten ...
plate. Carefully position the soapstone sides. Start with the front stone which is slightly smaller than the rear stone. The bottom edge of the soapstone sides must be 3 mm outside the base plate. Check that the soapstone is cor- rectly aligned at the rear and the front. Hook the pre-installed screws into the top frame. Do not tighten the screws until all the soapstone sides are in position. When all the soapstone sides are in position, the six screws for the top frame can be tightened. Also tighten the front screws on the top frame. 520T ...
lighting and maintenance for the Contura 500 series” before lighting the fire for the first time. Attach the manufacturer’s markings that give details of the serial number and safe installation distances to the heat reflector, as illustrated. Finish by installing the heat deflector, the hearth surround and the grate disc Apply some small blobs of silicone on the upper side of the soapstone sides and place the top stone on top. Position the hot air vent and the cover on the soap- stone top. 520T ...
Lay the stove body on its back on the pallet. Secure the base-plate with four socket-head (female) screws. Fit them from the inside of the base-frame into the fix- ing lugs on the base-plate. Do not tighten the screws until the stove is standing upright on a level surface. Loosen the two screws on the rear of the base-frame by turning them three revolutions anticlockwise. Then hook the rear panel into place. 10 10 VANADIUM No. 7 CHROME x 3 Secure the rear panel by inserting two hexagon screws at the top and tightening them just 2 or 3 revolutions. Important! Clean the glass panels carefully before fi ...
560T Stand the stove on the floor plate and check the safe installation distances. If the stove has a rear flue, connect the stove to the chimney before fitting the soapstone surround. If, on the other hand, the stove has a top flue, fit the soapstone surround first. Remember to fit the hot-air vent before connecting the stove to a top flue. Unpack the soapstone top and side sections. Always handle soapstone with care, especially the edges, which are very sensitive to impact. Lay the soapstone sides on expanded polystyrene on a flat surface. Lay them end to end in two’s, with the outside facing down. Squeeze three small ...
connecting plate. Screw the plate into place over the joint in the two soapstone sections. Insert a screw into the top end of the soapstone side section and turn the screw two revolutions only. Lift the soapstone side section carefully into place. Support the joint with one hand to minimise the stress on the connecting plate. At the base of the stove, the soapstone sides must project approx. 3 mm outside the external edge of the base-plate. Check to make sure that the soapstones fit well at the back and front of the stove. Hook the factory-fitted screw into place on the top frame. Do not tight ...
fitted, tighten the six screws in the top frame. Adjust the screws on the top of the metal side panels so that they are level with the soapstone side sections. Squeeze a few blobs of silicone onto the top edge of the soapstone side sections and lay the soapstone top in place. Lay the hot-air vent and covering cap in place on the soapstone top. Important! Before the stove is used, it must be inspected by an authorised chimney sweep or the relevant authority. Please read carefully through the separate “Lighting and Maintenance Instructions for the Contura 500 series” before lighting the s ...
Wood stove PDF Instructions
Kaminofen Auriga 28/816 Anleitung Seite 2 - 6 Instruction Page 7 - 11 Instructions Page 12 - 16 Aanwijzing Pagina 17 - 21 Manual de instrucciones Página 22 - 26 - DIN EN 13240 - 15a BV-G D GB F NL E Königshütte Complete device guide for the Konigshutte Auriga Wood stove. The manual highlights product maintenance, installation guides, regulatory notices, device features.
Operating and setup manual for the Heat & Glo CURVE 100 Wood stove. This reference includes operating modes, warranty information, operating conditions.
SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER. B Y : S H E R W O O D I N D U S T R I E S L T D OWNER’S MANUAL PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE. Kodiak Wood Stove Models: 1200 & 1 Operation guide for the Enviro Kodiak 1200 Wood stove. The guide offers support information and assembly reference, calibration steps, device safety checks.
180-PE1006 v1.11 October 3, 2018 The authority having jurisdiction (such a municipal building department, fi re department, etc.) should be consulted before installation to determine the need to obtain a permit. Pour la version française de nos manuels S.V.P Official operating instructions for the Valley Comfort Systems Blaze King PRINCESS PE1006 Wood stove. The guide explains setup and network setup, supported accessories, service procedures.