Contura 550 Installation Instructions Manual

Specifications

Brand: Contura
Category: Wood stove
Model: 550 (Installation Instructions Manual), prvWrek.mtFko
File Type: PDF
File Size: —
Pages: 16 pages

Download Document

Get a high-quality, printable PDF version of this manual for offline use.

Download PDF Manual (16 pages)

⚠️ Download Safety: This PDF is completely safe to download (last scan date: 02/05/2026).

Read Online

Read the Contura 550 Installation Instructions Manual online using the built-in PDF viewer.

550 Installation Instructions Manual: Key Pages of Document

Stove lit with solid biofuels

Type designation Contura 550 Manufacturing number See rating plate on the stove Intended area of use Heating of rooms in residential buildings Fuel Wood MANUFACTURER Name NIBE AB / Contura Address Box 134, Skulptörvägen 10 SE-285 23 Markaryd, Sweden CHECKS According to AVCP System 3 European standard EN 13240:2001 / A2:2004 Test institute Rein-Ruhr Feuerstätten Prüfstelle, NB 1625, has checked declared performance and issued test report no. RRF-40 09 2088 PERFORMANCE DECLARATION No. C550-CPR-130601-SE-1 DECLARED PERFORMANCE Essential characteristics Performance Harmonised technica ...

List of Contents

Technical details 68 Removing the loose parts 68 Connection to chimney 70 Supply of combustion air 71 Installation distances 72 Assembly 73 Installing base 76 Installing drawer 77 A warm welcome to Contura A warm welcome to the Contura family. We hope you will get a great deal of pleasure from your new stove. As a new owner of a Contura stove, you have secured a product with timeless design and long service life. Contura also has a combustion process that is both environmentally friendly and efficient, for the best heat production. Read through these installation instructions carefully before installation. Read how to best light ...

up to 79%

Model 550 Height (mm) 1010 Width (mm) 500 Depth (mm) 440 Weight (kg) 100 Type approved in accordance with: European standard EN-13240 Swedish environmental and quality marking, P-marking cert. no. 220309 Norwegian standard NS 3059, SINTEF 043-140 German standard DIN, 18.891, RO-91 03 529 Danish standard DS/EN 13240 Plus, id no. 598 Removing the loose parts If the insert needs to be put down to be moved, loose components should be removed. When the stove is installed reinstall the components in reverse order. 1 Fire bars 2 Grate disc 3 Heat deflector 4 Hearth cladding (Vermiculite). 1 ...

How to remove the hearth surround (Vermiculite)

Handle the vermiculite with care. Lift the smoke baffle with one hand whilst removing the sides pieces. Reinstall in reverse order 4 How to remove the heat deflector 3 2 1 ...

Ø ca 180 mm

Ø ca 180 mm LEK ! 4 6 5 1 3 2 70 GB CHIMNEY Connection to chimney Rear connection to a masonry chimney Top connection to the chimney Make sure that the connector gasket does not work loose when the connection pipe is placed on the connector. If further sealing material is required, heat- resistant sealant may be used. The back panel must be installed before the stove is rear connected. The hot air grille must be installed before chimney top connection. • The stove meets the requirements for connecting to chimneys dimensioned for 350°C flue gas temperature. • The external diameter of the connection sleeve is 150 mm. � ...

Supply of combustion air

When a stove is installed in a room, the demand for air supply to the room increases. Air can be provided indirectly via a vent in the outer wall or via a duct from the outside that is connected to the connector on the underneath of the stove. The amount of air needed for combustion is approx. 25m3/h. The connector has an external diameter of 67 mm. When duct routing further than 1 m the pipe diameter must be increased to 100 mm and a correspondingly larger wall vent must be selected. In hot areas the duct should be insulated with 30 mm mineral wool covere ...

* If the stove is placed on a hearth plate made of glass for example (accessory), the height from the floor is affected by a distance corresponding to the thickness of the hearth plate. Also applies to

separate glass hearth plates (accessory). ** To prevent discolouration of painted non-flammable walls we recommend that the same side distance as to combustible walls is used. The minimum distance in front of the stove opening to combustible parts of the building or interior decoration must be at least 1 m. When top connecting a steel flue, please refer to the particular manufacturer's installation instructions. Observe the safety distan ...

Installing C 550

ASSEMBLY 1 3 2 To facilitate the installation of the side panels, the two upper screws for the back panel must not be tightened before the side panels are installed. Installing rating plate Supplied rating plate positioned on underneath of heat deflector, or with fan option on the inside of the stove. ...

Hold the side panel approximately 20 mm above the base panel

and turn the side panel’s front edge around the edge of the base frame. Hook the side panel on the back panel. Align and depress the side panel end over the base panel’s shaft pin. Clean the glass thoroughly before installing the side panels! ...

It is extremely important that the installation is inspected by an authorised chimney sweep before

the stove is used. Also read the ”Lighting instructions”, before lighting for the first time. Final inspection of the installation 5 6 ASSEMBLY ...

When installing the base, the

knockout in the back panel must always be removed for the supply of convection air. 1 3 2 4 ASSEMBLY Installing base ...

When installing the drawer,

the knockout in the back panel must always be removed for the supply of convection air. 1 3 2 ASSEMBLY Installing drawer ...

811146 IAV SE-EX C550 - 4

2014-01-28 Contura reserves the right to change dimensions and procedures described in these instructions at any time without special notice. The current edition can be downloaded from www.contura.eu NIBE AB · Box 134 · 285 23 Markaryd · Sweden www.contura.eu ...

Wood stove PDF Instructions

ULC S627
Drolet ULC S627
27.03.2026 40 pages

READ AND KEEP THIS MANUAL FOR REFERENCE 45397A.doc PYROPAK E.P.A. WOOD STOVE MANUAL US ENVIRONMENTAL PROTECTION AGENCY PHASE II CERTIFIED WOOD STOVE Verified and tested following ULC S627 and UL 1482 Standards by: STOVE BUILDER INTERNATIONAL INC.. 1700, Leon- Quick start guide for the Drolet ULC S627 Wood stove. It provides technical information on usage procedures, repair references, device reset instructions.

GLAS AMITY
Plamen International GLAS AMITY
30.05.2026 44 pages

GLAS AMITY 02. 2009. Техничко упутство за пећ од ливеног гвожђа SRB all-guides com Practical operating guide for the Plamen International GLAS AMITY Wood stove. It includes troubleshooting procedures and operation, hardware components, service procedures, setup tips.

SKG20
Dimplex SKG20
21.08.2026 4 pages

640 620 390 THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE. Dimensions (millimetres) Installation and Operating Instructions 08/19238/1 Issue 1 Dimplex Stockbridge Stove Model: SKG20 Important Safety Advice: When using electri Operating handbook for the Dimplex SKG20 Cooktop. It explains warranty information, shutdown procedures, network configuration.

CDW1000L02
DutchWest CDW1000L02
05.07.2026 2 pages

This manual describes the installation and operation of the Model CDW1000L02 non-catalytic wood heater. This heater meets US Environmental Protection Agency’s emission limits for wood heaters. Under specific conditions this heater has been shown to deliver h Operating instructions for the DutchWest CDW1000L02 Wood stove. This manual offers stepwise instructions for regulatory notices, performance optimization, device safety checks, error handling.