Datalogic DS2400A Manual
Text of the manual
DS2400A QUICK GUIDE
DS2400A
General View:
Laser Safety:
The scanner is classified as a Class 2 laser
product according to EN 60825-1 regulations
and as a Class II laser product according to
CDRH regulations.
Disconnect the power supply when opening the
device during maintenance or installation to
avoid exposure to hazardous laser light.
There is a safety device which allows the laser to
be switched on only if the motor is rotating above
the threshold for its correct scanning speed.
The motor and laser beam can be switched off
through a software command (see also the
WinHost Help On Line).
CAUTION-CLASS 3B LASER LIGHT
WHEN OPEN AVOID EXPOSURE TO BEAM
This product conforms to the applicable
requirements of 21CFR1040 at the date
of manufacture.
LASER LIGHT
DO NOT STARE INTO BEAM
CLASS 2 LASER PRODUCT
MAX. OUTPUT RADIATION 1 mW
EMITTED WAVE LENGTH 630~680 nm
TO EN 60825-1:2001
R
C
US
218441
N2468
Figure A
1
2
3
4
8
7
6
5
Power On / Data TX LED
External Trigger LED
Good Read LED
Laser On LED
Warning and Device Class Label
Laser Beam Output Window
Accessory Mounting Holes
Mounting Holes
For further details on product installation, see the
complete Reference Manual on the installation CD-ROM.
DS2400A can be configured through the WinHost
Windows-based software program available on the
installation CD-ROM.
For configuration it is necessary to create a cable
connecting the scanner to the PC as indicated in the
“How To Build A Simple Interface Test Cable” section of
this guide, otherwise you can use the C-Box 100.
Power Supply:
- This product is intended to be installed by Qualified
Personnel only.
- All Models:
This accessory device is intended to be supplied by a UL
Listed or CSA Certified Power Unit with «Class 2» or LPS
power source which supplies power directly to the
scanner via the 25-pin connector.
Warning and Device Class Labels
The laser diode used in this device is classified
as a class 3B laser product according to EN
60825-1 regulations and as a Class IIIb laser
product according to CDRH regulations. As it is
not possible to apply a classification label on
the laser diode used in this device, the following
label is reproduced below.
LASER LIGHT
AVOID EXPOSURE TO BEAM
CLASS 3B LASER PRODUCT
MAX. OUTPUT RADIATION 7 mW
EMITTED WAVE LENGTH 630~680 nm
TO EN 60825-1 (2001)
Laser Diode Class Label
Any violation of the optic parts in particular can
cause radiation up to the maximum level of the
laser diode (7 mW at 630 to 680 nm).
WEEE Compliance:
7
6
5
1
2
3
4
8
DS2400A QUICK GUIDE
2
Model Description:
DS2400A - X X X 0
Reading Range
0 = Short range
1 = Medium range
2 = Long range
Communication Interface
2 = RS232/RS485 main + RS232 aux
Optic Version
0 = Linear
1 = Raster
Reading Performance:
Version
Reading Distance
Max Code Resolution
mm (mils)
Speed
scans/s
0XX0
75 mm (3 in) - 340 mm (13.4 in) on 0.35 mm (14 mils) codes
0.20 (8)
600 to 1000
1XX0
100 mm (3.9 in) - 440 mm (17.3 in) on 0.50 mm (20 mils) codes
0.25 (10)
600 to 1000
2XX0
190 mm (7.5 in) - 600 mm (23.6 in) on 0.50 mm (20 mils) codes
0.35 (14)
600 to 1000
Technical Features:
ELECTRICAL FEATURES
SOFTWARE FEATURES
Power Supply
10 –30 Vdc
Readable Codes
Power Consumption
5 W maximum
Main Serial Interface
Programmable:
RS232;
RS485 Full-Duplex/Half-
Duplex;
Auxiliary Interface
RS232
*
*
*
*
*
*
*
EAN/UPC
(including Add-on 2 and Add-on 5)
Code 39
2/5 Interleaved
Code 128
EAN 128
Codabar
Code 93
Baudrates
150 to 115200
* = ACB readable
ISBT 128
Inputs
Pharmacode
External Trigger
(optocoupled NPN or PNP)
Headers and
Up to four header and four
Voltage max.
30 Vdc
Terminators
terminator characters
Current Consumption 25 mA
Operating Modes
On-Line, Automatic,
max.
Serial-On-Line, Test
Outputs)
Configuration Modes
Through menus using:
OUT1, OUT2
(optocoupled)
WinHost utility
Host Mode (commands from
VCE max.
40 Vdc
one of the serial ports)
Collector Current
40 mA continuous;
Code Selection
Up to six different codes
max.
130 mA pulsed
during one reading phase
VCE Saturation
1V at 10 mA max.
Decoding Safety
Can enable multiple good
Power Dissipation
90 mW at 40 °C
reads of the same code
max.
(Ambient temp.)
Special Functions
ACB (Advanced Code Builder)
Motor Off
OPTICAL FEATURES
Parameter Storage
Non-volatile internal EEPROM
Light Source
semiconductor laser diode
ENVIRONMENTAL FEATURES
Wavelength
In the range 630 to 680 nm
Operating
0° to +40 °C (+32° to +104 °F)
Safety Class
Class 2 - EN 60825-1; CDRH
Temperature
Storage
-20° to +70 °C (-4° to +158 °F)
USER INTERFACE
Temperature
LED Indicators
Laser ON, Good Read,
Humidity max
90% non condensing
External Trigger,
Vibration Resistance 14 mm @ 2 to 10 Hz;
Data TX / Power ON
IEC 68-2-6 test FC
1.5 mm @ 13 to 55 Hz;
2 G @ 70 to 200 Hz;
PHYSICAL FEATURES
2 hours on each axis
Dimensions
68x83.6x34 mm (2.7x3.29x1.3 in)
Shock Resistance
30 G;
Weight
330 g. (11.64 oz)
IEC 68-2-27 test EA
11 ms; 3 shocks on each axis
Protection Class
IP65
DS2400A QUICK GUIDE
3
Accessories:
Name
Description
Part Number
GFC-2100
90° Reading Device
93A201000
GFC-2000
105° Reading Device
93A201080
OM2000
Oscillating Mirror
93A251031
INT-30 (for C-Box 100)
20 mA Current Loop Interface Board
93A151022
C-BOX 100/200
Connection Box
93ACC1510, 93ACC1520
C-BOX 300/310
Connection Box Profibus
93A301000, 93A301030
C-BOX 400/410
Connection Box DeviceNet
93A301010, 93A301040
MEP-542/543
Photocell Kit NPN/PNP
93ACC1727, 93ACC1728
Electrical Connections:
DS2400A is equipped with a cable terminated by a 25-pin female D-sub connector for connection to the power
supply, communication interface and input/output signals. You can bring system cables directly to the 25-pin
connector or you can connect the scanner directly to one of the various C-Box models and bring system wiring to
it (see the relative C-Box Installation Manual).
CAUTION
Do not connect GND and SGND to different (external) ground references. GND and SGND
are internally connected through filtering circuitry which can be permanently damaged if
subjected to voltage drops over 0.8 Vdc.
The details of the connector pins are indicated in the following table:
25-pin D-sub female connector pinout
Pin
Name
Function
13
VS
Power supply input voltage +
25
GND
Power supply input voltage -
1
CHASSIS
Chassis Ground
9
VS
External Trigger supply voltage +
18
EXT TRIG+
External Trigger +
19
EXT TRIG-
External Trigger -
8
OUT1 +
Output 1 +
11
OUT2 +
Output 2 +
12, 22
OUT REF
Output reference
20
RXAUX
Auxiliary RS232
21
TXAUX
Auxiliary RS232
23
CTSAUX
Auxiliary handshake RS232
24
RTSAUX
Auxiliary handshake RS232
6, 10, 14,
15, 16, 17
NC
Not Connected
25-pin female connector
Pin
RS232
RS485
Full-Duplex
RS485
Half-Duplex
2
TX232
TX485+
RTX485+
3
RX232
RX485+
4
RTS232
TX485-
RTX485-
5
CTS232
RX485-
7
SGND
SGND
SGND
DS2400A QUICK GUIDE
4
Mechanical Installation:
23.3*
0.92
14
0.55
84
3.31
4
0.16
10.3
0.41
40
1.57
0.41
10.3
40
1.57
14.7
0.58
M 4 n° 4
1.29
32.7
mm
inch
68
2.68
46
1.81
DS2100A
9
4.2
7.8
20°
2.5
73
42
R 40
4.2
90°
30
13.8
17.5
2.5
23
mm
4.2 n° 2
1 x 45° n° 2
*
The quote refers to the scan line
Input/Output Connections:
INPUT NPN
INPUT NPN MEP-543
EXT TRIG+
18
19
+ 5V
DS2400A
EXTERNAL TRIGGER
Signal
V
Vext 30 Vdc max.
EXT TRIG-
Input NPN command using external power
MEP-543 Connector
DS2400A
18
19
+ 5V
VS
9
25
GND
EXT TRIG+
EXT TRIG-
4
3
2
1
(brown)
(white)
(blue)
Input NPN command using MEP-543 Photocell
OUTPUT
EXTERNAL TRIGGER
DS2400A
Signal
18
19
+ 5V
VS
9
25
GND
Ground
V
EXT TRIG+
EXT TRIG-
Input NPN command using DS2400A power
USER INTERFACE
+
8/11
12/22
OUT REF
DS2400A
Vext 40 Vdc max.
C
E
Output open collector connections
INPUT PNP
18
19
+ 5V
DS2400A
EXTERNAL TRIGGER
V
Signal
Ground
EXT TRIG+
EXT TRIG-
Vext 30 Vdc max.
Input PNP command using external power
VCE max = 40 Vdc
I max = 40 mA continuous
EXTERNAL TRIGGER
DS2400A
18
19
+ 5V
VS
9
25
GND
Ground
V
Signal
EXT TRIG+
EXT TRIG-
Input PNP command using DS2400A power
DS2400A
DS2400A QUICK GUIDE
5
Connectivity:
RS232 Main Interface Connections
RS485 Main Interface Connections
RS232 Point-to-point layout
RS485 Point-to-point layout
c Main Serial Interface (RS232)
c Main Serial Interface (RS485 Full Duplex)
dAuxiliary Serial Interface (Local Echo) (RS232)
dAuxiliary Serial Interface (Local Echo) (RS232)
eExternal Trigger (for On-Line Mode)
eExternal Trigger (for On-Line Mode)
Pass-through layout
Multiplexer layout
c Main Serial Interface (RS232)
c Main Serial Interface (RS485 Half-Duplex)
dAuxiliary Serial Interface (RS232)
dAuxiliary Serial Interface (Local Echo) (RS232)
eExternal Trigger (for On-Line Mode)
eExternal Trigger (for On-Line Mode)
RS232 Master/slave layout
RS485 Master/slave layout
c Main Serial Interface (Slaves RS232 only)
c Auxiliary Serial Interface (RS232)
dAuxiliary Serial Interface (RS232)
d Main Serial Interface (RS485 Half-Duplex)
eExternal Trigger (for On-Line Mode)
eExternal Trigger
Host
MX4000
Host
DS2400A
Terminal
Host
DS2400A
Terminal
Host
DS2400A
DS2400A
Host
DS2400A
Slave
DS2400A
Slave
DS2400A
Master
Host
DS2400A
Slave
DS2400A
Slave
DS2400A
Master