Bewator K42 Technical Manual

Text of the manual

Copyright © February 2001 Bewator AB, Solna, Sweden.

Material from this manual may only be copied with the consent in writing of Bewator. Bewator reserves the right to alter both the content of the manual and the design of the product. Document number: 80717-1 Bewator AB are part of Bewator Group AB, which develops and markets a complete security product ra

K42 Installation ............................................. 4

Svenska......................................................... 5 English .......................................................... 7 Dansk............................................................. 9 Francais....................................................... 11 Suomi .......

12-24 V IN

LOCK TA A B C D A B C D CODE 1 CODE 2 1 2 3 4 5 ON OFF 0V EXIT Ÿ1 Ÿ2 - + 6

Inställning av kod

Flytta bygelblocken mitt för de siffror som skall utgöra Kod 1 respektive Kod 2. OBS! Om bara Kod 1 används – bygla mellan 8 och 9. Exempel (se figuren på sidan 4): Kod 1: 0123 Kod 2: 4589 Tidsstyrning av kod En kod kan kopplas bort vissa tider, t ex från ett kopplingsur. När plintnr 7 och 9 sluts bortkopplas kod

Inkoppling av relä

Gäller ellås med omvänd funktion. Tekniska data Strömförsörjning: 12-24 V AC/DC. Strömförbrukning: 8 mA i vila. Reläutgång: Potentialfritt växlande relä, max. 1A, 28V DC. Temperaturområde: -35° till +55°C. Omgivningskrav: Inom - eller utomhus (IP54 design). Mått: 140 x 80 x 40 mm (hxbxd). Rekommenderad monteringshö

Setting the codes

Move the jumpers next to the digits that should make up codes 1 and 2 respectively. NOTE! If only one code (Code 1) is to be used, link terminal block nos. 8 and 9 together. Do NOT leave any jumpers off. Example (see figure on page 4): Code 1: 0123 Code 2: 4589 Timing the codes The codes can be disabled for certain periods,

Relay terminal blocks

For locks with failsafe (power to lock) function, connect lock to terminal 5, not 3. Technical data Power voltage: 12-24 V AC/DC. Power consumption: 8 mA quiescent. Relay output: Voltage free relay, max. 1A, 28V DC Temperature Range: -35° to +55°C. Environment: Indoor – or outdoor use (IP54 design). Dimension: 140 x 80 x 40 m

Programming av kode

Sæt jumperne ud for de tal, som ønskes for kode 1 og kode 2. Hvis kun kode 1 anvendes, så kortslutt terminal 8 og 9. Eksempel (se figuren på side 4): Code 1: 0123 Code 2: 4589 Tidsindstilling Koderne kan frakobles på bestemte tidspunkter med et ur. Når terminal 7 og 9 er kortsluttet frakobles kode 1. Når terminal 8 o

Other Keypad Manuals