Apxalarm APX32EN Quick Start Manual
Read Online
Read the Apxalarm APX32EN Quick Start Manual online using the built-in PDF viewer.
Key Pages of Document
APX32EN Security System Quick Start Guide UUUULLLL APX32EN is not intended for UL985 Household Fire applications unless a 24-hour backup battery (P/N LYNXRCHKIT-HC or LYNXRCHKIT-SHA) is installed. Introduction This Quick Start Guide can help you install the rechargeable APX32EN quickly and easily by providing the basic steps for installation using the built-in defaults. For more detailed information and important notes, refer to ...
09012-002-V0 LOCKING TABS LOCKING TABS 09012-003 BATTERY RECEPTACLE WIRING TERMINALS NOTE LYNXRCHKIT-HC BATTERY PACK SHOWN TAPE BATTERY PACK RETAINER INCOMING PHONE LINE TO HANDSET PHONE LINE WARNING: TO PREVENT RISK OF SHOCK DISCONNECT TELEPHONE LINE AT TELECOM JACK BEFORE SERVICING THIS UNIT. WEEKLY TESTING IS REQUIRED TO ENSURE PROPER OPERATION OF THIS SYSTEM ALL OUTPUT CIRCUITS ARE POWER LIMITED. ...
Step Action 1. Enter Programming mode: Installer Code + 8 0 0 2. Set a programming default as follows: Press *97, then press number 1 to select default table. Refer to APX32EN Programming Default Tables. 3. Program the variable data fields as follows: a. RF House ID - Press *24, then enter the desired 2-digit RF House ID for wireless keypads. ...
transmission or manually. If using RF Learning proceed to c. 1). If using the manual mode skip to c. 2). 1) RF Learning – Two (2) transmissions (two key depressions at least five second apart) will be required for BR type or four (4) transmissions (fault, restore and fault, restore) for UR or RF type. BR type devices can be enrolled on ...
For programming data values and Powerline Carrier Devices other than those listed in the default tables, see the Installation Instructions. Function Default Value *20 Installer code 4112 *21 Quick arm enable 1 *22 Keypad backlight timeout 0 *23 Forced bypass 0 *24 RF house ID code 0,0 *25 Powerline carrier device house code 0 *26 Chime-by-zone 0 *27 Real-time clock display 1 *29 Daylight saving time start/end month 3,11 ...
27 loop 2 disarm 28 loop 4 arm stay 29 loop 1 no alarm response 30 loop 3 arm away 31 loop 2 disarm 32 loop 4 arm stay 33 loop 1 no alarm response 92 duress 99 silent alarm NOTES: • Table 1 supports a Powerline Carrier Device programmed as device 8, which closes and stays closed upon burglary alarms and restores after bell tim ...
Security Functions Checking system status: STATUS (high level messages); press STATUS again for secondary messages. To arm in STAY mode: Press and hold down STAY (or enter your code + STAY ) See note below. To restart exit delay: STAY (applies only if system is armed in Stay mode and Quick Exit option has been enabled) To arm in AWAY mode: Press and hold down AWAY (or enter your code + AWAY ) Se ...
To remotely disarm system: + [1] To remotely arm in AWAY mode: + [2] To remotely arm in STAY mode: + [3] To remotely arm in AWAY or STAY with NO DELAY: + [2] or [3] + [0] To remotely bypass a zone: + [6] + zone no. To remotely activate forced bypass: + [6] + [#] Note: Force bypass option must be enabled ...