Amprobe 5XP-A Operation & User’s Manual

Specifications

Brand: Amprobe
Category: Multimeter
Model: 5XP-A (Operation & User’s Manual), prmTl2EnaLeHU
File Type: PDF
File Size: —
Pages: 29 pages

Download Document

Get a high-quality, printable PDF version of this manual for offline use.

Download PDF Manual (29 pages)

⚠️ Download Safety: This PDF is completely safe to download (last scan date: 07/07/2026).

Read Online

Read the Amprobe 5XP-A Operation & User’s Manual online using the built-in PDF viewer.

5XP-A Operation & User’s Manual: Key Pages of Document

99 Washington Street

Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.TestEquipmentDepot.com ...

Compact Digital Multimeters

2A MAX FUSED CAT 600V CAT 1000V CAT 300V COM A MAX 1000V 750V Hz Temp V mA A mA 400 1000 A A 35XP-A RANGE NON CONTACT VOLTAGE HOLD V HZ V auto-off °C OFF °F mA A A 1832 400 5 6 4 2 3 1 1.) Display Afficheur Anzeige Display Pantalla 2.) Feature Buttons boutons de fonctions funktionstasten pulsanti delle funzioni botones de función 3.) Function/Range Switch commutateur de gamme/fonction. funktion/bereich-schalter selettore funzione/portata selector de la función y del rango 4.) Test Lead Connections branchements des cordons de test messleitungsanschlÜsse boccole per i cavetti conexiones de los conductores de prueba ...

Compact Digital Multimeters

Users Manual • Manual de uso • Mode d’emploi • Bedienungshandbuch • Manuale d’Uso English ...

Limited Warranty and Limitation of Liability

Your Amprobe product will be free from defects in material and workmanship for 1 year from the date of purchase. This warranty does not cover fuses, disposable batteries or damage from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling. Resellers are not authorized to extend any other warranty on Amprobe’s behalf. To obtain service during the warranty period, return the product with proof of purchase to an authorized Amprobe Test Tools Service Center or to an Amprobe dealer or distributor. See Repair Section for details. THIS WARRANTY IS YOUR ONLY REMEDY. ...

Compact Digital Multimeters

CONTENTS SAFETY INFORMATION............................................................2 SYMBOLS USED IN THIS MANUAL .........................................3 MAKING MEASUREMENTS......................................................3 Verify Instrument Operation...............................................3 Range Selection...................................................................4 Correcting an Overload (0o or -0o) Indication: ...............4 Measuring DC Voltage (See Figure 1).................................4 Measuring AC Voltage (See Figure 2).................................5 Preparing for Current Measurement ...

• Inspect the DMM, test leads and accessories before every

use. Do not use any damaged part. • Never ground yourself when taking measurements. Do not touch exposed circuit elements or test probe tips. • Do not operate the instrument in an explosive atmosphere. • Exercise extreme caution when: measuring voltage >20 V // current >10 mA // AC power line with inductive loads // AC power line during electrical storms // current, when the fuse blows in a circuit with open circuit voltage >1000 V // servicing CRT equipment. • Always measure current in series with the load – NEVER ACROSS a voltage source. Check fuse first. Never replace a fuse wi ...

In addition to autoranging (Models 15XP-B and 35XP-A only)

you can manually select and lock a range by pressing the RANGE button. RANGE appears on the display to indicate that manual ranging is active and the range is locked. When appropriate, each subsequent press of the range button steps the meter to the next higher range. When the highest range is reached the next press returns the meter to the lowest range. To return to autoranging press the RANGE button. If RANGE still shows on the display, autoranging is not available for the selected function.Use autorange for all initial measurements. Then, when appropriate, use the RANGE but ...

4. Connect the test probes to the circuit test points.

5. Read the display, and, if necessary, correct any overload (0o) conditions. Measuring DC Voltage (See Figure 2) 1. Set the Function Switch to . 2. Select the desired RANGE. The default AC voltage range is 2 V on the 15XP-B and 4 V on the 35XP-A. 3. Connect the test leads: Red to V , Black to COM. 4. Connect the test probes to the circuit test points. 5. Read the display, and, if necessary, correct any overload (0o) conditions. Preparing for Current Measurements • Turn off circuit power before connecting the test probes. • Allow the meter to cool between measurements, if current mea ...

6. Connect the test probes in series with the load (to the

measurement points). 7. Turn on power to the circuit being measured. 8. Read the display, and, if necessary, correct any overload (0o or -0o) conditions. Measuring AC Current (See Figure 4) 1. Set the Function Switch to a current function and range, μA, mA, or A. 2. Select the desired RANGE (5XP-A only). 3. Connect the test leads: Red to mA or A, Black to COM. 4. Turn off power to the circuit being measured. 5. Open the test circuit (X) to establish measurement points. 6. Connect the test probes in series with the load (to the measurement points). 7. Turn on power to the circuit being measur ...

7. Read the display. If 0o appears on the highest range,

the resistance is too large to be measured or the circuit is an open circuit. 8. (15XP-B) The 2000 M range has a fixed 10-count offset in the reading. For example, when measuring 1100 M, the display reads 1110. The 10 residual must be subtracted to obtain the actual value of 1100 M Testing for Continuity (See Figure 6) 1. Set the Function Switch to . 2. Connect the test leads: Red to V , Black to COM. 3. Turn off power to the circuit being measured. 4. Discharge any capacitors that may influence the reading. 5. Connect the test probes across the resistance or the two points of t ...

3. Turn off power to the circuit being measured.

4. Discharge the capacitor using a 100 k resistor. 5. Free at least one end of the capacitor from the circuit. 6. Connect the test probes across the capacitor. 7. Read the display. Measuring Temperature (35XP-A only) (See Figure 9) 1. Set the function switch to appropriate °C or °F range. 2. Connect the K-type thermocouple to a TEMP adapter (XR-TA). Match the polarity of the adapter to the polarity of the thermocouple. 3. Connect the TEMP adapter to the V  and COM inputs. Note: The 35XP-A is compatible with all K-type thermocouples. The K-type bead thermocouple supplied with the meter is not ...

3. Press the NCV button. The display goes blank, a tone

sounds and the red LED next to the NCV button on the front panel lights up to verify that the instrument is operational. While pressing the button, hold the top- center of the meter (sensor location) close to the conductor/circuit in question. 4. If a voltage in the range of 70 to 600 V ac is present, a tone sounds and the red LED next to the NCV button on the front panel lights up. Testing Battery Voltage (5XP-A only) (See Figure 12) 1. Set the Function Switch to the appropriate BATT setting, 1.5 V or 9 V. 2. Connect the test leads: Red to BATT 1.5 V or BATT 9 V, Black to COM. 3. Connect the t ...

Input Test Lead Warning

The meter emits a continuous tone when a test lead is placed in the mA or A input jack and the Function/Range Switch is not set to a correct current position. (If the meter is connected to a voltage source with leads connected for current, very high current could result). All current ranges are protected by fast acting fuses. MIN MAX Measurements (Model 5XP-A only) The MIN MAX feature reads and updates the display to show the maximum or minimum value measured after you press the MIN MAX button.Pressing the MIN MAX button for less than 1 second will put the meter into a mode of displaying the maximum or min ...

The HOLD button causes the meter to capture and

continuously display a measurement reading. To use the HOLD feature make a measurement, and then,after the reading has stabilized, momentarily press the HOLD button. You can remove the test leads and the reading will remain on the display. Pressing the HOLD button again releases the display. Product Maintenance Cleaning To clean the meter, use a soft cloth moistened with water. To avoid damage to the plastic components do not use benzene, alcohol, acetone, ether, paint thinner,lacquer thinner, ketone or other solvents to clean the meter. Troubleshooting If the meter appears to operate ...

To replace the fuse:

1. Remove the 2 rear-case screws. 2. Separate the case. 3. Remove and replace the 2 A fuse (15XP-B or 35XP-A) or 0.315 fuse (5XP-A). 4. Reassemble the meter. Fuse: Fast Blow 2 A/1000 V, minimum interrupt rating 30 kA (6 x 32 mm) (Amprobe® FP200). Fast Blow 0.315 A/1000 V minimum interrupt rating 30 kA (6.3 x 32 mm) (Amprobe® FP300) SPECIFICATIONS Display: 5XP-A and 15XP-B:3 ½ digit liquid crystal display (LCD) with a maximum reading of 1999. 35XP-A: 3 ¾ digit liquid crystal display (LCD) with a maximum reading of 3999. Polarity: Automatic, positive implied, negative polarity indication. Overrange: 0o or -0o is displayed. ...

Overload protection: 1000 V dc or 750 V ac

Accessories: One pair test leads TL245, 9 V battery (installed),holster, magnet strap, Users Manual, Type K Bead Thermocouple (35XP-A only), and temperature adaptor (35XP-A only). Altitude: 6561.7 Feet (2000 m) P  Safety: Conforms to EN61010-1, Rev-2; CAT I 1000V, CAT II 600V, CAT III 300V(5XP-A,35XP-A), CAT II 1000 V, CAT III 600 V(15XP-B), class 2 and pollution deg. 2; CSA 22.2 -1010-1. EMC: Conforms to EN61326-1. This product complies with requirements of the following European Community Directives: 89/ 336/ EEC (Electromagnetic Compatibility) and 73/ 23/ EEC (Low Voltage) as amended by 93/ 68/EEC(CE Mar ...

FP300 Fuse – 0.315 A / 1000 V (5XP-A)

H-XP Magne-Grip® Holster, clip, magnet, and strap XR-TA Input Adapter for K-type thermocouple (35XP-A) TP255 K type thermocouple See www.amprobe.com for detailed specifications of the Amprobe® XP digital multimeters. 5XP-A Electrical Specifications (at 23°C ± 5°C, < 75 % R.H.) DC VOLTS Ranges: 200 mV, 2 V, 20 V, 200 V, 1000 V Accuracy: ± (1.0 % rdg + 1 dgt) AC VOLTS (45 Hz to 500 Hz) Ranges: 200 mV, 2 V, 20 V, 200 V, 750 V Accuracy: ± (1.5 % rdg + 5 dgts) DC CURRENT Ranges: 200 µA, 2 mA, 20 mA, 200 mA, ± (1.5 % rdg + 1 dgt) AC CURRENT (45 Hz to 500 Hz) Ranges: 200 µA, 2 mA, 20 mA, 200 mA, ± (2.0 ...

Ranges: 1.5 V, 9 V

Accuracy: ± (3.5 % rdg + 2 dgts) OVERLOAD PROTECTION Voltage, Resistance, Diode, Continuity: 1000 VDC or 750 VAC rms 200 mV Range: 1000 VDC / 750 VAC rms (3 minutes) Current: 0.315 A / 1000 V fast blow ceramic fuse 6.3 × 32 mm mA JACK: Input warning detects wrong switch/input jack configuration AUXILIARY FEATURES DATA HOLD: Freeze the latest reading on the display. MIN/MAX: Record the maximum and minimum reading in a measurement. 15XP-B Electrical Specifications (at 23°C ± 5°C, < 75 % R.H.) DC VOLTS Ranges: 200 mV, 2 V, 20 V, 200 V, 1000 V Accuracy: ±(0.5 % rdg + 1 dgt) AC VOLTS (45 Hz to 500 Hz) Ranges: 200 mV, ...

Accuracy: ± (1.0 % rdg + 4 dgts) on 200 to 2 M

ranges: ± (3.0 % rdg + 5 dgts) on 20 M range ± {5.0 % (rdg -10 dgt) + 20 dgt} on 2000 M range CONTINUITY Audible indication: Less than 25  DIODE TEST Test current: 1.2 mA (approximate) Accuracy: ±(1.5 % rdg + 3 dgts) Open circuit volts: 3.0 dc typical LOGIC TEST Thresholds Logic 1 (Hi): 2.8 V ± 0.8 V Thresholds Logic o (Lo): 0.8 V ± 0.5 V Test voltage: TTL 5 VDC OVERLOAD PROTECTION Voltage, Resistance, Diode, Continuity, Logic: 1000 VDC or 750 VAC rms Current: 2 A / 1000 V fast blow ceramic fuse 6.3 × 32 mm mA JACK: Input warning detects wrong switch / input jack configuration AUXILIA ...

Multimeter PDF Instructions

MIC-2505
Sonel MIC-2505
07.06.2026 26 pages

Full user manual for the Sonel MIC-2505 Multimeter. The manual covers procedures for operating guidelines, operating conditions, troubleshooting, setup tips.

III Series
Fluke III Series
13.06.2026 12 pages

® 79/26 Series III Multimeter Instruction Sheet � Read First: Safety Information • Never use the meter if the meter or test leads look damaged. • Be sure the test leads and switch are in the correct position for the desired measurement. • Never measur Practical operating guide for the Fluke III Series Multimeter. It explains maintenance and product safety, replacement parts, basic operation, setup.

UT61 series
UNI-T UT61 series
01.08.2026 51 pages

Complete operating guide for the UNI-T UT61 series Multimeter. This documentation provides step-by-step guidance on device safety checks, daily usage, startup procedures, maintenance procedures.

12070T
southwire ip67 12070T
11.09.2026 17 pages

10A 30 sec MAX CAT III 1000V CAT IV 600V FUSED MAX 400mA Temp Auto Power Off Waterproof every 15 min mA COM Hz CAP ® 12070T ! Autoranging Multimeter Operating Instructions 12070T True RMS Multimeter Multímetro True RMS 12070T UL61010-1 Instrucciones de uso T Official user manual for the southwire ip67 12070T Multimeter. The manual guides users through installation, installation support, setup, functional overview.