AMX IRIS IRSERIAL DATA CAPTURE DEVICE Instruction Manual
Text of AMX IRIS IRSERIAL DATA CAPTURE DEVICE Instruction Manual
AMX Limited Warranty and Disclaimer
AMX Corporation warrants its products to be free of defects in material and workmanship under normal use for
three (3) years from the date of purchase from AMX Corporation, with the following exceptions:
•
Electroluminescent and LCD Control Panels are warranted for three (3) years, except for the display and touch
overlay components that are warranted for a period of one (1) year.
•
Disk drive mechanisms, pan/tilt he
AMX IRIS IRSERIAL DATA CAPTURE DEVICE Table of Contents
i
IRIS Infrared/Serial Data Capture Unit
Table of Contents
Product Information .................................................................................................1
Specifications .................................................................................................................... 1
Installation .................................................................................................................3
Ca
IRIS Infrared/Serial Data Capture Unit
Product Information
The IRIS Infrared Capture Unit is a stand-alone, self contained unit used to capture infrared (IR) or
wired-IR function signals from a hand controller. Hand controllers (HC) are used to control a wide
variety of audiovisual equipment that includes monitors, VCRs, TVs, and CD players. After you
capture IR functions with the IRIS unit (FIG. 1 on page 2), the functions are sent t
IRIS Infrared/Serial Data Capture Unit FIG. 1 IRIS front and rear views
WIRED
12V
IN
IRE
12
5
IN
OUT
RS-232
RS-232
UP
SIGNAL
IR
READY
VERIFY
DOWN
SEND
SIGNAL LED
IR window
VERIFY LED
READY LED
Alphanumeric display
UP button
DOWN button
SEND button
12 V connector
8-pin data
connector
RS-232 6-pin
RJ-11 connector
RS-232 DB-9
connector
IRIS Infrared/Serial Data Capture Unit Installation
Capturing HC Functions
The two modes you can use to capture HC functions are default and special function. You use
default mode, which is automatically set when you connect power to the IRIS unit, to capture the
majority of HC functions. The table below shows the IRIS unit settings for default mode. Before
capturing HC functions, make sure the baud rate in the IRIS unit is set properly, and
IRIS Infrared/Serial Data Capture Unit Capturing HC functions in SP mode
If you cannot capture an HC function in default mode, set the IRIS unit to special function (SP)
mode. Perform these steps to capture HC functions in SP mode:
1.
Press and release the UP and SEND pushbuttons at the same time. The message SP briefly
appears in the display and the UP LED lights. The IRIS unit is now in SP mode.
2.
Perform the Capturing HC functions in def
IRIS Infrared/Serial Data Capture Unit Baud Rate Settings
The default communication setting for the IRIS unit is 9600 baud. You can change the baud rate
with the UP, DOWN, and SEND pushbuttons. You must set the IRIS unit's baud rate to match the baud
rate of the PC running the IRLIB software program to store HC functions.
To set the baud rate:
1.
Disconnect the power supply from the IRIS unit.
2.
Press and hold the UP, DOWN, and SEND pushbut
IRIS Infrared/Serial Data Capture Unit Cables and Adapters
Depending on your IRLIB programming configuration, one or more cables may be required.
Connectors are shown from the wiring side. FIG. 2 shows a computer-to-Axcess Control System
(DB-25 to DB-9) wiring diagram; FIG. 3 shows a computer-to-Axcess Central Controller (DB-9-
to-DB-9) wiring diagram.
HC IR Functions
The following table lists the HC IR functions in standard order.
FIG. 2 C
IRIS Infrared/Serial Data Capture Unit HC IR Functions (Standard Order) (Cont.)
Function
Description
Function
Description
15
’5’
36
CD
16
’6’
37
Tuner
17
’7’
38
Phono
18
’8’
39
Aux
19
’9’
40
AM/FM
20
’+10’ or ’+100’
41
Play < (play reverse)
21
Enter (used in conjunction with
number typically)
42
A/B
IRIS Infrared/Serial Data Capture Unit Troubleshooting
This section provides product solutions to common problems.
E1 or ER messages
The Er/E1 message appears when there is a communication problem with the PC and not an error in
capturing the IR functions.
E1 or Er Messages
Problem
Solution:
A Hand Control can’t seem to
capture the codes.
The AXB-IRIS is able to verify the
codes, but when the Send Command
is pressed, an Er appears on th
AMX reserves the right to alter specifications without notice at any time.
brussels • dallas • los angeles • mexico city • philadelphia • shanghai • singapore • tampa • toronto* • york
3000 research drive, richardson, TX 75082 USA • 469.624.8000 • 800.222.0193 • fax 469.624.7153 • technical support 800.932.6993
041-004-x1352 4/02 ©2002 AMX Corporation. All rights reserved. AMX, the AMX logo, the building ico