AMX IRIS IRSERIAL DATA CAPTURE DEVICE Instruction Manual

Text of AMX IRIS IRSERIAL DATA CAPTURE DEVICE Instruction Manual

AMX Limited Warranty and Disclaimer

AMX Corporation warrants its products to be free of defects in material and workmanship under normal use for three (3) years from the date of purchase from AMX Corporation, with the following exceptions: • Electroluminescent and LCD Control Panels are warranted for three (3) years, except for the display and touch overlay components that are warranted for a period of one (1) year. • Disk drive mechanisms, pan/tilt he

AMX IRIS IRSERIAL DATA CAPTURE DEVICE Table of Contents

i IRIS Infrared/Serial Data Capture Unit Table of Contents Product Information .................................................................................................1 Specifications .................................................................................................................... 1 Installation .................................................................................................................3 Ca

IRIS Infrared/Serial Data Capture Unit

Product Information The IRIS Infrared Capture Unit is a stand-alone, self contained unit used to capture infrared (IR) or wired-IR function signals from a hand controller. Hand controllers (HC) are used to control a wide variety of audiovisual equipment that includes monitors, VCRs, TVs, and CD players. After you capture IR functions with the IRIS unit (FIG. 1 on page 2), the functions are sent t
IRIS Infrared/Serial Data Capture Unit FIG. 1 IRIS front and rear views WIRED 12V IN IRE 12 5 IN OUT RS-232 RS-232 UP SIGNAL IR READY VERIFY DOWN SEND SIGNAL LED IR window VERIFY LED READY LED Alphanumeric display UP button DOWN button SEND button 12 V connector 8-pin data connector RS-232 6-pin RJ-11 connector RS-232 DB-9 connector
IRIS Infrared/Serial Data Capture Unit Installation Capturing HC Functions The two modes you can use to capture HC functions are default and special function. You use default mode, which is automatically set when you connect power to the IRIS unit, to capture the majority of HC functions. The table below shows the IRIS unit settings for default mode. Before capturing HC functions, make sure the baud rate in the IRIS unit is set properly, and
IRIS Infrared/Serial Data Capture Unit Capturing HC functions in SP mode If you cannot capture an HC function in default mode, set the IRIS unit to special function (SP) mode. Perform these steps to capture HC functions in SP mode: 1. Press and release the UP and SEND pushbuttons at the same time. The message SP briefly appears in the display and the UP LED lights. The IRIS unit is now in SP mode. 2. Perform the Capturing HC functions in def
IRIS Infrared/Serial Data Capture Unit Baud Rate Settings The default communication setting for the IRIS unit is 9600 baud. You can change the baud rate with the UP, DOWN, and SEND pushbuttons. You must set the IRIS unit's baud rate to match the baud rate of the PC running the IRLIB software program to store HC functions. To set the baud rate: 1. Disconnect the power supply from the IRIS unit. 2. Press and hold the UP, DOWN, and SEND pushbut
IRIS Infrared/Serial Data Capture Unit Cables and Adapters Depending on your IRLIB programming configuration, one or more cables may be required. Connectors are shown from the wiring side. FIG. 2 shows a computer-to-Axcess Control System (DB-25 to DB-9) wiring diagram; FIG. 3 shows a computer-to-Axcess Central Controller (DB-9- to-DB-9) wiring diagram. HC IR Functions The following table lists the HC IR functions in standard order. FIG. 2 C
IRIS Infrared/Serial Data Capture Unit HC IR Functions (Standard Order) (Cont.) Function Description Function Description 15 ’5’ 36 CD 16 ’6’ 37 Tuner 17 ’7’ 38 Phono 18 ’8’ 39 Aux 19 ’9’ 40 AM/FM 20 ’+10’ or ’+100’ 41 Play < (play reverse) 21 Enter (used in conjunction with number typically) 42 A/B
IRIS Infrared/Serial Data Capture Unit Troubleshooting This section provides product solutions to common problems. E1 or ER messages The Er/E1 message appears when there is a communication problem with the PC and not an error in capturing the IR functions. E1 or Er Messages Problem Solution: A Hand Control can’t seem to capture the codes. The AXB-IRIS is able to verify the codes, but when the Send Command is pressed, an Er appears on th

AMX reserves the right to alter specifications without notice at any time.

brussels • dallas • los angeles • mexico city • philadelphia • shanghai • singapore • tampa • toronto* • york 3000 research drive, richardson, TX 75082 USA • 469.624.8000 • 800.222.0193 • fax 469.624.7153 • technical support 800.932.6993 041-004-x1352 4/02 ©2002 AMX Corporation. All rights reserved. AMX, the AMX logo, the building ico

AMX Other Owners Instructions: