Wheelock TPI-100 Installation Instructions Manual
Text of the manual
Sheet 1 of 17
273 Branchport Avenue
Long Branch, NJ 07740
Thank you for using our products.
(800) 631-2148
www.wheelockinc.com
INSTALLATION INSTRUCTIONS
MODEL TPI-100
TELEPHONE PAGING RING START INTERFACE
Use this product according to this instruction manual. Please keep this instruction manual for future reference.
APPLICATION INFORMATION:
Whe
Sheet 2 of 17
GENERAL APPLICATION INFORMATION:
The Telephone Paging Interface (TPI-100) provides ring start (90V/20Hz) paging access from:
A.
A Central Office (CO) line.
B.
A Centrex number line.
C.
A station level position on telephone systems which provide analog ring voltage (90V/20Hz), and 600 OHM audio to their
extension phones.
The TPI-100 is
Sheet 3 of 17
Telephone "Hang Up" Tone
One-Way
Paging
Talkback
Paging
One-Way Paging
Using FZC-3 Zone Control
Tone Detect
Jumper
Immediate
VOX
VOX
VOX
EN.
Delayed
VOX
VOX
VOX
EN.
None (Silent)
VOX
MAN.
MAN.
DIS.
Not Detectable by Frequency
Immediate
MAN.
MAN.
MAN.
DIS.
Detector
Delayed
VOX
MAN.
MAN.
DIS.
Chart 2.
Timer Control Jumper and Tone Detect
Sheet 4 of 17
Zone
3
Chart 3.
Paging Priorities for Multiple Line Applications
Higher priority TPI-100's interrupt lower priority TPI-100's and place their paging on "Hold". If the interrupted paging phone
does not Hang Up, then the page will automatically be restored when the higher priority page is concluded.
The following Figures 1 thru 4 illust
Sheet 5 of 17
Figure 3.
Single Line
One Zone, One-Way Paging
With Central Amplifier and Transformer
Equipped Speakers and Horns
Figure 3 depicts a one zone system consisting of a single TPI-100, a central amplifier, and multiple transformer equipped
speakers/horns. The Timer Control Jumper should be placed in the "VOX" position.
Figure 4.
Single Li
Sheet 6 of 17
Figure 5.
Multiple Lines
Zone and All Call Paging
Figure 5 depicts a multi zone system with "All Call". The system consists of multiple CO/Centrex or analog extension lines.
Each zone line has its own TPI-100 and page devices. An additional line and TPI-100 are dedicated to "All Call". The paging
devices connected to the TPI-100's c
Sheet 7 of 17
Figure 6.
Multiple Lines
Zone, Group and All Call Paging
Figure 6 depicts a multi zone system with group page and "All Call". The system consists of multiple CO/Centrex or analog
extension lines. Each zone line has its own TPI-100 and page devices. An additional line and TPI-100 is assigned to each page
group, and to "All Call". Th
Sheet 8 of 17
There are three ways of accessing the zones with this configuration. First the zones may be accessed individually. Second, the
zones may be accessed in groups. Third, all zones can be accessed simultaneously.
TO ACCESS AN INDIVIDUAL ZONE, dial the number of the line connected to the TPI-100 controlling that zone. An alert
tone is s
Sheet 9 of 17
Supply Voltage (Nominal)
-24VDC
Supply Voltage Range
-21.6VDC TO -26.4VDC
Supply Current (Idle - BGM)
64mA (See Note 1)
Supply Current (Nominal - Page)
109mA
Supply Current (Max. - All/Group Page)
134mA (See Note 2)
Alert Tone Frequency
680Hz +/-10%
Alert Tone Duration
450m Seconds +/-10%
Audio Input/Output Levels (Note 3)
-15dBM(0.1VR
Sheet 10 of 17
WIRING INSTRUCTIONS (SEE FIGURE 9):
CAUTION: Use class 2 power source only.
1.
Make sure 24VDC power supply is disconnected from the 115VAC power source.
2.
Connect Tip and Ring from the telephone line to TB2, terminals 8 and 7 respectively.
3.
Connect the background music source to TB2, terminals 3 and 4.
4.
In single line applicati