Sheet 1 of 17

273 Branchport Avenue Long Branch, NJ 07740 Thank you for using our products. (800) 631-2148 www.wheelockinc.com INSTALLATION INSTRUCTIONS MODEL TPI-100 TELEPHONE PAGING RING START INTERFACE Use this product according to this instruction manual. Please keep this instruction manual for future reference. APPLICATION INFORMATION: Whe

Sheet 2 of 17

GENERAL APPLICATION INFORMATION: The Telephone Paging Interface (TPI-100) provides ring start (90V/20Hz) paging access from: A. A Central Office (CO) line. B. A Centrex number line. C. A station level position on telephone systems which provide analog ring voltage (90V/20Hz), and 600 OHM audio to their extension phones. The TPI-100 is

Sheet 3 of 17

Telephone "Hang Up" Tone One-Way Paging Talkback Paging One-Way Paging Using FZC-3 Zone Control Tone Detect Jumper Immediate VOX VOX VOX EN. Delayed VOX VOX VOX EN. None (Silent) VOX MAN. MAN. DIS. Not Detectable by Frequency Immediate MAN. MAN. MAN. DIS. Detector Delayed VOX MAN. MAN. DIS. Chart 2. Timer Control Jumper and Tone Detect

Sheet 4 of 17

Zone 3 Chart 3. Paging Priorities for Multiple Line Applications Higher priority TPI-100's interrupt lower priority TPI-100's and place their paging on "Hold". If the interrupted paging phone does not Hang Up, then the page will automatically be restored when the higher priority page is concluded. The following Figures 1 thru 4 illust

Sheet 5 of 17

Figure 3. Single Line One Zone, One-Way Paging With Central Amplifier and Transformer Equipped Speakers and Horns Figure 3 depicts a one zone system consisting of a single TPI-100, a central amplifier, and multiple transformer equipped speakers/horns. The Timer Control Jumper should be placed in the "VOX" position. Figure 4. Single Li

Sheet 6 of 17

Figure 5. Multiple Lines Zone and All Call Paging Figure 5 depicts a multi zone system with "All Call". The system consists of multiple CO/Centrex or analog extension lines. Each zone line has its own TPI-100 and page devices. An additional line and TPI-100 are dedicated to "All Call". The paging devices connected to the TPI-100's c

Sheet 7 of 17

Figure 6. Multiple Lines Zone, Group and All Call Paging Figure 6 depicts a multi zone system with group page and "All Call". The system consists of multiple CO/Centrex or analog extension lines. Each zone line has its own TPI-100 and page devices. An additional line and TPI-100 is assigned to each page group, and to "All Call". Th

Sheet 8 of 17

There are three ways of accessing the zones with this configuration. First the zones may be accessed individually. Second, the zones may be accessed in groups. Third, all zones can be accessed simultaneously. TO ACCESS AN INDIVIDUAL ZONE, dial the number of the line connected to the TPI-100 controlling that zone. An alert tone is s

Sheet 9 of 17

Supply Voltage (Nominal) -24VDC Supply Voltage Range -21.6VDC TO -26.4VDC Supply Current (Idle - BGM) 64mA (See Note 1) Supply Current (Nominal - Page) 109mA Supply Current (Max. - All/Group Page) 134mA (See Note 2) Alert Tone Frequency 680Hz +/-10% Alert Tone Duration 450m Seconds +/-10% Audio Input/Output Levels (Note 3) -15dBM(0.1VR

Sheet 10 of 17

WIRING INSTRUCTIONS (SEE FIGURE 9): CAUTION: Use class 2 power source only. 1. Make sure 24VDC power supply is disconnected from the 115VAC power source. 2. Connect Tip and Ring from the telephone line to TB2, terminals 8 and 7 respectively. 3. Connect the background music source to TB2, terminals 3 and 4. 4. In single line applicati