Sandall Stones Road, Kirk Sandall Industrial Estate, Kirk Sandall, Doncaster DN3 1QR

Tel: +44 (0) 8443 715523 Fax: +44 (0) 8443 715524 www.polypipe.com/ventilation www.polypipe.com ...

With pull-cord switch

With Timer With Humidistat, timer and pull-cord switch over-ride With Humidistat Twin speed with pull cord switch Twin speed with Humidistat and pull cord boost SVC150PB SVC150TB SVC150HTB SVC150HB SVC150PBTW SVC150HBTW SILAVENT WINDOW/WALLFANS The SVC6 range are axial extractor fans suitable for use in domestic kitchens and light commercial environments. They may be used in other applications where a high ...

Incorrect siting of an extractor fan can

severely impair its efficiency. It is therefore, important that the fan is correctly sited using the following principles. • To ensure maximum air flow through the whole room, mount in the window, wall or ceiling furthermost from the air inlet point at high level. • Do not position a fan where temperatures are likely to exceed 50ºC (for example above a cooker hob or ...

Remove front cover retaining screw (5) and lift off front cover (1), see note below.

REASSEMBLY Reassemble the fan unit in reverse order. When reassembling the fan unit it is important not to over-tighten any screw or the clamp nuts. NOTE: Liftingthetopedgeofthefrontcoverwillmakeiteasiertoremove. WARNING Positioning of th ...

It is recommended that fans be connected into the lighting circuit, with double pole

(3mm) isolation provided before the room light switch and suitably fused, in accordance with IEE Regulations. Window Fans should be connected to power supply using a flexible cord with conductors of between 0.75mm2 and 1.5mm2 only. Wall and ceiling ...

We recommend the use of this fixing kit as it contains all the necessary parts to surface

mount or flush fit the SVC6 fan unit. SURFACEMOUNTING Cut a hole through wall in desired position to take the 150mm duct supplied in the fixing kit. It is important that there is at least a 5º downward slope towards the outside to allow for condensation drainage. The duct should be cut so that it is flush with both sides of the wall less 60m ...