Cerlic BB2 Manuals
Cerlic BB2 Manual (24 pages)
- Identifier: id-1533363
- Brand: Cerlic
- Device: Control Unit
- Type: Manual , PDF
- Key Aspects: Step-by-Step Setup Guides, Data Backup Instructions, Best Practices for Maintenance
- UPD Date: 15.06.2026
- Source File: 1467913.pdf
- Pages: 24
- Description: User instruction booklet for the Cerlic BB2. This manual covers installation, operation, and firmware updates, maintenance schedule, component replacement, safety protocols.
Key Pages and Contents:
-
BB2 Control Box
BB2 is the control box to which most Cerlic sensors can be connected. The measured signal is converted to a linearized 4-20mA output signal. The BB2 allows the user to easily adjust settings and serves as a display for the measured output. The unit also i -
- 5 -
6. Unpacking the BB2 control box The unit has been tested and approved before delivery from the supplier. Please check that no visible damages are apparent in this shipment. DAMAGES If damages occurred during shipment, immediately contact the shipping company and the Cerlic representative. The -
- 24 -
APPENDIX 4, Extending Shielded Cable 1. Open the enclosures lid on the shielded box and fasten the box where appropriate. Illustration 1: Cables with shield and fitting. 2. Put the fitting (2) and container (3) on the sensor cable. 3. Peel the covering off the cable (1) to L1 (90 mm). 4. Cut -
- 2 -
Table of contents 1. Introduction............................................................................................................3 2. A few words about this manual...........................................................................3 3. Design.................................
Cerlic BB2 Manual (24 pages)
- Identifier: id-1533364
- Brand: Cerlic
- Device: Control Unit
- Type: Manual , PDF
- Key Aspects: Calibration and Adjustment Methods, Periodic Maintenance Tasks, User Training Recommendations
- UPD Date: 24.08.2026
- Source File: 1467912.pdf
- Pages: 24
- Description: User instruction manual for the Cerlic BB2. It outlines maintenance guidelines and maintenance procedures, operation, connectivity options.
Key Pages and Contents:
-
- 20 -
15. Getting started Start-up of the instrument begins when power is supplied. While a self-test is being performed, it may take up to 30 seconds for the sensor to initialize and be identified. Changes to the settings can not be made until the BB2 control box has recognized the sensor. When re -
- 13 -
12. Alarm Limits When a measured value goes above a high alarm limit or goes below a low alarm limit an alarm is triggered, and an alarm window is displayed on BB2 telling what sensor and reason caused the alarm. If a second alarm occurs a second line is added in the window. When an alarm is -
- 23 -
Mounting in the 4-20 mA module in the BB2 control box The 4-20mA module shall be mounted in a BB2 control box. Make sure the power to the control box is switched off before mounting the module. Connect yourself and the control box chassis to protective ground before opening the antistatic pac -
- 24 -
Getting started with the 4-20 mA module A step by step guide to get the 4-20mA module up and running. • Make sure the BB2 box to be used is switched off. • Open the front and locate the expansion module connector. • Connect yourself and the control box chassis to protective ground befor
Cerlic BB2 Manual (13 pages)
- Identifier: id-1903680
- Brand: Cerlic
- Device: Control Unit
- Type: Manual , PDF
- Key Aspects: Installation Overview, Environmental Impact Assessments, Industry Comparisons
- UPD Date: 04.04.2026
- Source File: 1819080.pdf
- Pages: 13
- Description: Installation reference manual for the Cerlic BB2. This guide presents instructions on diagnostic information, setup guidelines, technical specifications, internal layout.
Key Pages and Contents:
-
- 7 -
Node Address The profibus-DP node address has to be set in the field. This can be done in two ways: 1. Two rotary switches on module can be set for 1-99 2. Setting the switches to 00 tells the module to use the address configured in the BB2 menu. It can be set from 1-125. To set up address -
- 6 -
7. Configuration BAUDRATE The baudrate on a Profibus-DP network is set during configuration of the master and only one baudrate is possible in a Profibus-DP installation. The Profibus-DP module has an auto baudrate detection function and the user does not have to configure the baudrate on the -
- 9 -
8. Indications The module is equipped with four LED's mounted at the front and one LED on the board, used for debugging purposes. The front LED's can be mounted in two ways, either top mounted or angle mounted. The function of the LED's are described in the table and figure below. No Indicatio -
MANUS09/17 VER 1.03
BB2 Profibus DP option
BB2: Related Instructions from Other Manufacturers
-
Lenovo ThinkCentre M50e Desktop Quick reference manual
96 -
Skipper DL850 Marine Equipment Operation and installation manual
72 -
Sony S2 Tablet Specifications
2 -
Igloo FRW655 Wine Cooler Operation & user’s manual
11 -
Emerson 1000W Microwave Oven Owner's manual
32 -
Amana AGR5630BDW0, AGR5630BDS0, AGR5630BDB0 Cooktop User instructions
28