Raychem EMDR-10 Manual 

File Specifications

Brand: Raychem
Category: Control Unit
Model: EMDR-10 (Manual ), pr9ajv4sx2IUw
File Info: Adobe Acrobat PDF (DjVu)
File Size: —
Pages: 32 pages

Download PDF

Download Raychem EMDR-10 Manual (32 pages)

Read Online:

Read the Raychem EMDR-10 Manual  online using the built-in PDF viewer.

Key Pages of Document

Air Temperature Sensor

Moisture Sensor Fixing Brackets (Hard-46) Label Manual DEUtScH Lieferumfang Regelgerät Temperatursensor Feuchtesensor Abstandshalter (Hard-46) Aufkleber Montage- und Bedienungsanleitung FRaNçaIS Contenu du conditionnement Régulateur Sonde de température ambiante Sonde d’humidité Supports (Ha ...

Table of Contents

Supplied Items ..........................................................................................2 1. Description ...........................................................................................5 1.1 Intended Purpose ...........................................................................5 1.2 Technical Data ...

Table des Matières

Contenu du conditionnement ....................................................................2 1. Description .........................................................................................21 1.1 Domaine d’application .................................................................. 21 1.2 Caractéristiques tech ...

1.1 Intended Purpose

The electronic control unit EMDR-10 is specifically designed for the control of gutter heating systems. Depending on outdoor temperature and moisture in the gutter the heating cable will only be switched on if necessary to ensure a correct drain of the snow water. 1.2 technical Data control Unit Supply voltage 230 VAC, ±1 ...

AC 230V 50/60Hz

IP 20 Relais: 10(4)A, AC 230V Alarm: 2(1)A, AC 230V Do not open while energized Nicht unter Spannung öffnen Ne pas ouvrir sous tension EMDR-10 T2A IEC127–2/V PE PE PE 1 2 3 4 5 6 7 8 9 10 11 °C –25 –20 –15 –10 –5 TEST °C –3 –2 –1 0 1 2 3 4 5 6 0 10 20 30 40 50 min 1 2 3 4 5 6 7 8 9 10 106 90 60 1.3 care and M ...

2.3 Installation and Dimensions of the temperature Sensor

A good positioning of the temperature sensor is crucial for the correct and efficient operation of the snow melting system. The temperature sensor should be placed on the North side of the building, in a position where it will always be away from direct sunlight. Moreover, it must be protected agai ...

2.5 Electrical Layout

- The length of the heating cable determines number and size of the fuse. - The use of a FI safety switch (30 mA) is obligatory stipulated by Raychem! - Local standards for electrical connection must be observed. - The device may only be connected up by an authorized electrician. - Use C-characteristic circuit breaker! Maximum heating ...

3.2 Parameter adjustments

The following parameters can be set by means of the respective dial: Adjustment of the air temperature threshold. The moisture sensor is being put into operation below this value. Adjustment of the moisture threshold. Above this value the heating cable is being energized, if the air temperature is below the setpoint. 1 = max. sens ...

4. Fault Messages and Trouble Shooting

The following faults are being detected by the control unit: Fault Reaction Break or short circuit of the temperature sensor LED “temperature“ flashes, alarm relay and load relay switch off Break of the moisture sensor LED “humidity” flashes, Short circuit of the moisture sensor alarm relay and load relay swi ...