TTDJ-99062N page 1 of 8

TTDJ Series Fully-Configurable Fault Annunciator Installation and Operations Manual TTDJ-99062N Revised 04-04 Section 50 (00-02-0412) Description The TTDJ is a solid-state fault annunciator and shutdown control system, with hour meter, designed to protect engines, compressors and their associ- ated equipment. Four TTDJ modules are ava ...

Sensor input number 32 is dedicated to Emergency Shutdown. The

Emergency Shutdown sensor input overrides the Test timer. Additionally, sensor input 29 can be configured as a Class “A” or Class “ESD” input. Remote Reset (optional, Setup 5 = 1, 3, 5 or 7) When the Remote Reset feature is selected, point 30 with a closed contact reset ...

The TTDJ-IGN models include a Backup Power Battery located within the

TTDJ module. To gain access to and to replace the battery do the following: 1. Make sure the area is made Non-Hazardous and shut down the System (remove power). 2. Using extreme caution remove the Power Supply Cover Screws (located on the back of the TTDJ module). 3. Gently pull the Power ...

TTDJ-99062N page 4 of 8

TYPICAL WIRING DIAGRAMS (All Models) IGN GRD FV+ FV- ALR NA NA NA 10-32 VDC Power supply Wiring must be kept separate from ignition leads. 90-350 VDC Capacitive Discharge Ignition System Typical Normally Open Sensors Typical Normally Closed Sensor (Remove jumper) Sensor Input Terminals NOTES: 1. Sensors are normally open or normally c ...

TTDJ-99062N page 5 of 8

STOP STOP STOP STOP STOP STOP STOP STOP TIMER "0" STOP STOP STOP RESET TIMER "0" (SETUP) TEST (SETUP) STOP TYPE SETUP TTDJ SENSOR SETUP MAP ...

TTDJ-99062N page 6 of 8

STOP STOP STOP STOP STOP STOP STOP STOP STOP STOP STOP STOP STOP STOP STOP STOP STOP STOP STOP STOP STOP STOP STOP STOP STOP STOP STOP STOP RESET (SETUP) STOP TEST (SETUP) TIMER "0" TTDJ SETUP MAP ...

User Set Up Menus

The following are the User Setup Menus for All TTDJ models: SETUP.1 = Class B1 Timer (0 – 5:00) SETUP.2 = Class B2 Timer (0 – 9:59) *SETUP.3 = Sensor 1-16 Type Setup SETUP.4 = Ignition Ground Delay (0 – 20 sec.) *SETUP.5 = Remote Setup 0= No Remote Lockout or Reset, #29 is Class “A” 1= Remote Reset, No Remote Lockout, #29 is C ...

TTDJ-99062N page 8 of 8

System Start Up Press the RESET key to clear any faulted sensor input and unground/enable ignition for engine operation. Apply starting power to the engine. The first thing displayed on versions with Tachometer is the engine speed. While there is time remaining in either of the Class “B” timers, the display will alternate between ...