GESTRA URS 2 Installation Instructions Manual

File Specifications

Brand: GESTRA
Category: Switch
Model: URS 2 (Installation Instructions Manual), pr8Xkgzb/IQCw
File Info: Adobe Acrobat PDF (DjVu)
File Size: —
Pages: 20 pages

Download PDF

Download GESTRA URS 2 Manual (20 pages)

Read Online:

Read the GESTRA URS 2 Installation Instructions Manual online using the built-in PDF viewer. This document explains how to operate the device, adjust settings and perform regular maintenance.

Key Pages of Document

Installation - continued -

Examples of Installation 4 2 5 8 6 6 3 1 MAX 55°C MAX 95% % IP 20 Fig. 9 Fig. 8 7 7 ...

Checking electrical connection..............................................................................................................16

Applying mains voltage..........................................................................................................................16 Contents - continued - Commissioning Page Limit switch............. ...

Faultfinding list for troubleshooting

GESTRA URS 2 An alarm is triggered although the measured values do not pass outside the adjusted limits. Fault: Incorrect selection of input 0 mA or 4 mA. Remedy: Check the output signal of the sensor and adapt the input of the URS 2 accordingly. If faults occur that are not listed above or cannot be corr ...

Flexible multi-core control cable can be used for wiring, min. conductor size 1.5 mm2.

GESTRA URS 2 Tools n Screwdriver for slotted screws, size 2.5 completely insulated according to DIN VDE 0680-1 Note n The rated voltage is indicated on the name plate. n When switching off inductive loads, voltage spikes are produced that may impair the ...

Universal signalling of two limits for MIN/MAX alarm based on 0/-20 mA input. The equipment is con

GESTRA URS 2 nected to a measuring sensor with current output 0 - 20 mA or 4 - 20 mA. Application for instance in combination with GESTRA level transmitter NRT 2-1b, continuous blowdown controller LRR 1-5b und conductivity transmitter LRT 1-5b, LRT 1-6b or ...

Apply mains voltage to the limit switch URS 2.

GESTRA URS 2 Commissioning Make sure that the URS 2 is wired according to the wiring diagram. Fig. 10 Checking electrical connection Applying mains voltage Performance test 1. Increase the 0/-20 mA signal of the external measuring sensor until it exceeds the MAX switchpoint adjusted in the URS 2. The LED 8 must light up ...

For measuring sensor with current output 0 to 20 mA (with external wire link for 4 to 20 mA),

GESTRA URS 2 input resistance 100 Ω. Output 2 volt-free relay contacts, contact rating 250 V, 500 W, 3 A resistive with a life of 4 x 105 switching cycles or 0.35 A inductive at 2 x 106 switching cycles, contact material: silver, hard gold plated. ...

n Screwdriver (5.5/100)

GESTRA URS 2 Attention n To provide sufficient ventilation, ensure a minimum spacing of 20 mm between adjacent units. Installation URS 2 On supporting rail 1. Clip temperature switch onto supporting rail. 2. Loosen cover screws 1 and detach cover 3 from its base 2. 3. Select cable entry 5 and remove corresponding seal. On mounting panel ...

For the disposal of the equipment observe the pertinent legal regulations concerning waste disposal.

GESTRA URS 2 Danger The terminal strips are live during operation. This presents the risk of severe cases of electric shock! Cut off power supply before mounting or removing the terminal strips and the housing cover. ...

The terminal strips of the URS 2 are live during operation.

GESTRA URS 2 This presents the risk of severe cases of electric shock! Cut off power supply before mounting or removing the terminal strips and the housing cover. Usage for the intended purpose Use limit switch URS 2 only for signalling limits based on the 0/-20 mA input. Safety note The ...

Usage for the intended purpose...............................................................................................................4

Safety note..............................................................................................................................................4 Danger............................................. ...

GESTRA URS 2 user guide recommended for: NRS 1-53, NRS 1-56, TRS 5-8, LRS 1-50, TRS 5-6.

⚠️ Download Safety

The Switch Installation instructions manual (20 pages) is completely safe to download (last scan date: 15/06/2026).

Switch: Frequently Requested PDF Instructions