Use air trap UNA 13P only to drain condensate from compressed-air and other gas
lines. The equipment may only be installed by qualified staff. Qualified staff are those persons who – through adequate training in engineering, the use and application of equipment in accordance with regulations concerning steam systems, and first ...
Scope of supply ..............................
GESTRA UNA 13P ...
Flow direction arrow
GESTRA UNA 13P Body Cover Name plate 3/8" BSP connection for fitting an air-balance pipe Gasket 17 x 23 Float lifting lever Handle Control unit Body gasket 77 x 67 x 1 Key B C D F G H I J A E ...
1. Remove cover from body , Fig. 2.
GESTRA UNA 13P 2. Lever control unit off its support using a screwdriver, Fig. 3. 3. Turn body, so that arrow points in the desired flow direction. 4. Position control unit on support and fix by two blows using a hammer and a punch, Fig. 4. 5. Clean seating surfaces of body and cover. 6. Insert new gasket and reasse ...
Scope of Supply
GESTRA UNA 13P UNA 13 P 1 Air trap type UNA 13 P 1 Installation manual Description Air traps with ball float and rolling valve ball for compressed air and gases. The trap is used to drain condensate from compressed-air and gas lines. Body with bolted cover. After removal of the cover the control unit is easily accessible, and can be exch ...
1) Physical and chemical properties comply with DIN grade. ASTM nearest equivalent grade is
stated for guidance only. Technical Data Pressure/Temperature Rating UNA 13 P PMA (Max. allowable pressure) [barg] 116 [psig] 230 TMA (Max. temperature) with steel valve ball [°C] 120 with Perbunan valve ball [°C] 140 ∆ PMX (Max. differential pressure) with ste ...
Spare Part List
GESTRA UNA 13P Item Designation Control unit Simplex Body gasket Orifice Control unit Simplex P Orifice 13 Orifice 13 Ref. no. 560415 560418 560493 I I J ...
Max. discharge capacity of cold condensate
GESTRA UNA 13P from compressed-air and gas lines. 1 1 Differential pressure (assuming discharge to atmospheric pressure) Capacity of cold condensate 1000 800 600 500 400 300 200 100 80 60 50 40 30 2000 1000 800 600 500 400 300 200 100 80 60 0.1 0.2 0.4 0.6 1 2 3 4 5 6 8 10 16 0.3 0.5 0.8 1 2 3 4 6 8 10 20 3 ...
Installation – continued –
For GESTRA air trap UNA 13 P we recommend the installation of an air-balance pipe to ensure the continuous condensate flow from the fluid line to the trap. The air-balance pipe also prevents the formation of water pockets. Air-Balance Pipe K K The GESTRA air trap UNA 13 P does not require any particular maintenance. It ...
GESTRA UNA 13P user guide recommended for: RK Series, CB 26, QuickEM, ZK 313, BW 31A.
⚠️ Download Safety
The Control Unit Installation instructions manual (14 pages) is completely safe to download (last scan date: 27/04/2026).
Control Unit: Frequently Requested PDF Instructions
-
National Instruments NI 9402 Control Unit Getting started manual
16 -
FAAC E124 Control Panel Manual
32 -
Asco 290 Series Control Unit Installation and maintenance instructions manual
9 -
M-system R3-PA2 Control Unit Instruction manual
5 -
FAAC 620 STANDARD Control Systems Installation manual
36 -
Grundfos CU 401 Modem Installation and operating instructions manual
36